GRTB18-P2487 – Cylindrical Photoelectric Sensors – SICK Sensors

USD $ 131.88

SKU: SICK 1101819

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1101819
Photoelectric Sensors Model: GRTB18-P2487
OEM Spec Ref 

Features

Functional principle Photoelectric proximity sensor
Functional principle detail Background suppression
Dimensions (W x H x D) 18 mm x 18 mm x 73.5 mm
Housing design (light emission) Cylindrical
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 3 mm … 300 mm 1)
Sensing range 20 mm … 150 mm 1)
Type of light Visible blue light
Light source LED 2)
Light spot size (distance) Ø 7 mm (100 mm)
Wave length 445 nm
Adjustment Potentiometer
Indication
LED green Operating indicator
Static on: power on
LED yellow Status of received light beam
Static on: object present
Static off: object not present
  • 1) Object with 90% remission (based on standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA
Switching output PNP
Output function Complementary
Switching mode Light/dark switching
Signal voltage PNP HIGH/LOW VS – (≤ 3 V) / approx. 0 V
Output current Imax. ≤ 100 mA 3)
Response time < 500 µs 4)
Switching frequency 1,000 Hz 5)
Connection type Male connector M12, 4-pin
Circuit protection 6)

7)

8)

Protection class III
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Fastening nuts (2 x)
Electromagnetic compatibility (EMC) EN 60947-5-2
Ambient operating temperature –25 °C … +55 °C 9)
Ambient temperature, storage –40 °C … +70 °C
UL File No. E348498
  • 1) Limit values. Operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) B = inputs and output reverse-polarity protected.
  • 8) D = outputs overcurrent and short-circuit protected.
  • 9) At Uv <=24V and IA<50mA.
Weight 0.024 kg