SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1077674
Photoelectric Sensors Model: GRL18S-N2436
OEM Spec Ref 

Features

Functional principle Photoelectric retro-reflective sensor
Functional principle detail Dual lens
Dimensions (W x H x D) 18 mm x 18 mm x 38.1 mm
Housing design (light emission) Cylindrical
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 0.03 m … 7.2 m 1)
Sensing range 0.06 m … 6 m 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) Ø 175 mm (7 m)
Wave length 650 nm
Adjustment None
Indication
LED green Operating indicator
Static on: power on
LED yellow Status of received light beam
Static on: object not present
Static off: object present
  • 1) Reflector PL80A.
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA
Switching output NPN
Output function Complementary
Switching mode Light/dark switching
Output current Imax. ≤ 100 mA 3)
Response time < 500 µs 4)
Switching frequency 1,000 Hz 5)
Connection type Male connector M12, 4-pin
Circuit protection 6)

7)

8)

Protection class III
Polarisation filter
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Fastening nuts (2 x)
Electromagnetic compatibility (EMC) EN 60947-5-2
Ambient operating temperature –25 °C … +55 °C 9)
Ambient temperature, storage –40 °C … +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
  • 1) Limit values. Operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) B = inputs and output reverse-polarity protected.
  • 8) D = outputs overcurrent and short-circuit protected.
  • 9) At Uv <=24V and IA<50mA.
Weight 0.0168 kg