SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1058194
Photoelectric Sensor Model: GRTE18S-N1317
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Energetic
Dimensions (W x H x D) 18 mm x 18 mm x 38.1 mm
Housing design (light emission) Cylindrical
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 3 mm … 115 mm 1)
Sensing range 5 mm … 100 mm 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) Ø 8 mm (100 mm)
Wave length 650 nm
Adjustment Potentiometer, 270°
Indication
LED indicator green Operating indicator
Static: power on
LED indicator yellow Status of received light beam
Static on: object present
Static off: object not present
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA
Switching output NPN
Switching mode Light switching
Signal voltage NPN HIGH/LOW Approx. VS / ≤ 3 V
Output current Imax. ≤ 100 mA 3)
Response time < 1,000 µs 4)
Switching frequency 500 Hz 5)
Connection type Cable, 3-wire, 2 m 6)
Cable material PVC
Circuit protection 7)

8)

9)

Protection class III
Housing material Plastic, ABS
Optics material Plastic, PMMA
Enclosure rating IP67
Items supplied Fastening nuts (2 x)
Electromagnetic compatibility (EMC) EN 60947-5-2
Ambient operating temperature –25 °C … +55 °C 10)
Ambient temperature, storage –40 °C … +70 °C
UL File No. NRKH.E348498 & NRKH7.E348498
  • 1) Limit values. Operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) At Uv > 24 V or ambient temperature > 49 °C, IA max. = 50 mA.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) Do not bend below 0 °C.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = inputs and output reverse-polarity protected.
  • 9) D = outputs overcurrent and short-circuit protected.
  • 10) At Uv <=24V and IA<50mA.