DT1000-S11101 – Long Range Distance Sensors – SICK Sensor

USD $ 6,006.00

SKU: SICK 1075436

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1075436
Distance Sensor Model: DT1000-S11101
OEM Spec Ref 

Mechanics/electronics

Supply voltage Vs DC 18 V … 30 V, reverse polarity protected
Ripple ≤ 5 Vpp 1)
Power consumption ≤ 22 W, With heating switched off 2)

≤ 35 W, With heating switched on 2)

Initialization time > 15 s
Housing material Metal (Aluminum alloy (AlSi12))
Window material Glass
Connection type Round connector M12 x 1
Indication Graphical, resistive touch display, status LEDs
Weight 980 g
Dimensions (W x H x D) 84 mm x 104.4 mm x 140.5 mm
Enclosure rating IP65 3)

IP67 3)

Protection class III (EN 61140)

1) May not fall short of or exceed VS tolerances.

2) With external load.

3) When plugged in with a suitable mating connector.

Performance

Measurement principle HDDM+
Measuring range 0.2 m … 155 m, 6 % remission 1) 2) 3)

0.2 m … 460 m, 90 % remission 1) 2) 3)

Target Natural objects
Resolution 0.001 mm … 100 mm, adjustable 4)
Repeatability ≥ 1 mm, See repeatability characteristic lines 1) 5) 6) 7)
Accuracy Typ. ± 15 mm 8) 9)
Response time 3 ms … 384 ms 7)
Measurement cycle time 1 ms

4 ms

16 ms

64 ms

128 ms

Output time ≥ 1 ms 10)
Light source Infrared light (905 nm, measuring laser)

Visible red light (650 nm, Adjustment aid)

Laser class 1, even with simultaneous operation of measurement and alignment laser (IEC 60825-1:2014, EN 60825-1:2014)
Typ. light spot size (distance) 5 mm x 20 mm (at 1 m) 11)

20 mm x 20 mm (at 5 m) 11)

35 mm x 25 mm (at 10 m) 11)

150 mm x 50 mm (at 50 m) 11)

290 mm x 80 mm (at 100 m) 11)

570 mm x 140 mm (at 200 m) 11)

Filter Rain and snow filter

Fog filter

Moving average distance value

Kalman filter

Moving average speed value

Max. object temperature +1,400 °C 12)
Additional function Selection of relevant distance and signal level range, Selection of first or last echo in selected distance and signal level range
Average laser service life (at 25 °C) 100,000 h 13)
Max. movement speed 128 m/s

1) With max. ambient light 100 kLux sunlight.

2) See measuring range diagram.

3) Dependent on remission and measuring cycle time.

4) Data interface resolution.

5) Statistical error 1 σ, environmental conditions constant, min. warm-up time > about 15 min.

6) 6 % … 90 % remission.

7) Dependent on selected filter settings and measuring cycle time.

8) See measurement accuracy diagram.

9) At T = +23 °C and after warm-up time > about 15 min.

10) Depending on interface used.

11) See light spot size diagram.

12) For object temperatures > +1,200 °C, the use of the additional filter is required for high-temperature applications. The additional filter reduces the measuring range limit by approx. 25%.

13) Measuring laser.

Interfaces

Ethernet ✔ , TCP/IP
Function Parameterization, output of measurement data
Data transmission rate 10/100 MBit/s
Serial ✔ , RS-422
Remark Switchable to SSI
Function Parameterization, output of measurement data
SSI
Remark Switchable to RS-422
Function Output of measurement data
Inputs/outputs
In1/Q1 Digital input, digital output (Switchable)
QA/Q2 Analog output, digital output (Switchable)
Q3 Digital output
Q4 Digital output
In2 Digital input
Digital input Internal pull-down circuit
HIGH switching voltage: min. 13 V … max. supply voltageLOW switching voltage: max. 5 VSwitching functions: deactivate measuring laser, activate alignment laser, preset
Digital output
Number 2 … 4 1) 2)
Type Push-pull: PNP/NPN
Maximum output current IA ≤ 100 mA
Analog output
Number 1
Type Current output
Current 4 mA … 20 mA 3)
Resolution 16 bit

1) Short-circuit protected, switching voltage UV – 4 V.

2) Internal pull-down switching, switching voltage HIGH: min. 13 V … max. supply voltage, switching voltage LOW: max. 5 V.

3) Max. load = (U– 7 V) / 21.5 mA.

Ambient data

Ambient temperature, operation –40 °C … +55 °C 1)

–40 °C … +95 °C, operation with cooling case

Ambient temperature, storage –40 °C … +75 °C
Max. rel. humidity (not condensing) ≤ 95 %
Effect of air pressure 0.3 ppm/hPa
Effect of air temperature –1 ppm/K
Temperature drift Typ. 0.25 mm/K
Typ. Ambient light immunity ≤ 100,000 lx
Mechanical load Shock: 30 g / 6 ms according to DIN EN 60068-2-27 (Ea), 6 axes

Continuous shock: 25 g / 6 ms according to DIN EN 60068-2-27 (fatigue), 500 shocks, 6 axes

1) At a temperature of –40 °C, a warm-up time of typ. 20 minutes is required (when supply voltage Vs = 24 V).

Weight 1.363 kg
Dimensions 20 × 17 × 28 cm

Related products