DT1000-S11101 – Long Range Distance Sensors – SICK Sensor
$ 6,292.00
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 1075436
Distance Sensor Model: DT1000-S11101
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 18 V … 30 V, reverse polarity protected |
Ripple | ≤ 5 Vpp 1) |
Power consumption | ≤ 22 W, With heating switched off 2)
≤ 35 W, With heating switched on 2) |
Initialization time | > 15 s |
Housing material | Metal (Aluminum alloy (AlSi12)) |
Window material | Glass |
Connection type | Round connector M12 x 1 |
Indication | Graphical, resistive touch display, status LEDs |
Weight | 980 g |
Dimensions (W x H x D) | 84 mm x 104.4 mm x 140.5 mm |
Enclosure rating | IP65 3)
IP67 3) |
Protection class | III (EN 61140) |
1) May not fall short of or exceed VS tolerances.
2) With external load.
3) When plugged in with a suitable mating connector.
Performance
Measurement principle | HDDM+ |
Measuring range | 0.2 m … 155 m, 6 % remission 1) 2) 3)
0.2 m … 460 m, 90 % remission 1) 2) 3) |
Target | Natural objects |
Resolution | 0.001 mm … 100 mm, adjustable 4) |
Repeatability | ≥ 1 mm, See repeatability characteristic lines 1) 5) 6) 7) |
Accuracy | Typ. ± 15 mm 8) 9) |
Response time | 3 ms … 384 ms 7) |
Measurement cycle time | 1 ms
4 ms 16 ms 64 ms 128 ms |
Output time | ≥ 1 ms 10) |
Light source | Infrared light (905 nm, measuring laser)
Visible red light (650 nm, Adjustment aid) |
Laser class | 1, even with simultaneous operation of measurement and alignment laser (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) | 5 mm x 20 mm (at 1 m) 11)
20 mm x 20 mm (at 5 m) 11) 35 mm x 25 mm (at 10 m) 11) 150 mm x 50 mm (at 50 m) 11) 290 mm x 80 mm (at 100 m) 11) 570 mm x 140 mm (at 200 m) 11) |
Filter | Rain and snow filter
Fog filter Moving average distance value Kalman filter Moving average speed value |
Max. object temperature | +1,400 °C 12) |
Additional function | Selection of relevant distance and signal level range, Selection of first or last echo in selected distance and signal level range |
Average laser service life (at 25 °C) | 100,000 h 13) |
Max. movement speed | 128 m/s |
1) With max. ambient light 100 kLux sunlight.
2) See measuring range diagram.
3) Dependent on remission and measuring cycle time.
4) Data interface resolution.
5) Statistical error 1 σ, environmental conditions constant, min. warm-up time > about 15 min.
6) 6 % … 90 % remission.
7) Dependent on selected filter settings and measuring cycle time.
8) See measurement accuracy diagram.
9) At T = +23 °C and after warm-up time > about 15 min.
10) Depending on interface used.
11) See light spot size diagram.
12) For object temperatures > +1,200 °C, the use of the additional filter is required for high-temperature applications. The additional filter reduces the measuring range limit by approx. 25%.
13) Measuring laser.
Interfaces
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
|
|||||||||||||
Digital input | Internal pull-down circuit HIGH switching voltage: min. 13 V … max. supply voltageLOW switching voltage: max. 5 VSwitching functions: deactivate measuring laser, activate alignment laser, preset |
||||||||||||
|
|||||||||||||
|
1) Short-circuit protected, switching voltage UV – 4 V.
2) Internal pull-down switching, switching voltage HIGH: min. 13 V … max. supply voltage, switching voltage LOW: max. 5 V.
3) Max. load = (Uv – 7 V) / 21.5 mA.
Ambient data
Ambient temperature, operation | –40 °C … +55 °C 1)
–40 °C … +95 °C, operation with cooling case |
Ambient temperature, storage | –40 °C … +75 °C |
Max. rel. humidity (not condensing) | ≤ 95 % |
Effect of air pressure | 0.3 ppm/hPa |
Effect of air temperature | –1 ppm/K |
Temperature drift | Typ. 0.25 mm/K |
Typ. Ambient light immunity | ≤ 100,000 lx |
Mechanical load | Shock: 30 g / 6 ms according to DIN EN 60068-2-27 (Ea), 6 axes
Continuous shock: 25 g / 6 ms according to DIN EN 60068-2-27 (fatigue), 500 shocks, 6 axes |
1) At a temperature of –40 °C, a warm-up time of typ. 20 minutes is required (when supply voltage Vs = 24 V).
Weight | 1.363 kg |
---|---|
Dimensions | 20.0 × 17.0 × 28.0 cm |