The Log class provides methods for controlling the special Log mode. The Log mode is a special mode of the camera models UI-124x/UI-324x/UI-524x and UI-125x/UI-325x/UI-525x in which a threshold defines at which point the linear sensitivity pass over into a logarithmic characteristic.

At very short exposure times (less than 0.1 ms) there may occur e.g. so-called crosstalk effects in the global shutter mode, which have the effect that the image content appears brighter in the vertical from top to bottom. This effect can be avoided by the Log mode.

hint_info

Note: This feature is currently only supported by the UI-124x/UI-324x/UI-524x and UI-125x/UI-325x/UI-525x models.

The following classes and methods exist:

LogManualGain

LogManualValue

Methods

Method

Description

Get

Returns the current Log mode.

GetDefault

Returns the default settings for the Log mode.

GetSupported

Returns if the Log mode is supported.

Set

Sets the Log mode.