The LogManualValue class provides methods for setting the gain. In the manual Log mode it is possible to display the information in the overexposed image areas. This mode is effective for exposure times below 5 ms.
You can adjust the threshold (0…12) at which the linear sensitivity pass over into a logarithmic characteristic. Here, the value "0" represents the lowest active level and "12" corresponds to the highest level.
Note: This feature is currently only supported by the UI-124x/UI-324x/UI-524x and UI-125x/UI-325x/UI-525x models. |
Methods
Method |
Description |
---|---|
Returns the current manual value of the Log mode. |
|
Returns the default settings for the manual value of the Log mode. |
|
Returns the range of the manual value of the Log mode. |
|
Sets the manual value of the Log mode. |