The LogManualGain class provides methods for setting the gain. In the manual Log mode it is possible to display the information in the overexposed image areas. This mode is effective for exposure times below 5 ms.
When using the manual Log mode no master gain is possible. The gain can be adjusted with LogManualGain. The gain can be adjusted in 5 levels. The level "3" corresponds to a gain factor of 1 for monochrome or color sensors. For the NIR sensor the level "1" corresponds to a gain factor of 1.
Example: A low level results in a low gain and may display more details in the overexposed image areas. A higher level gives a higher gain, thereby a darker image can be brightened.
Note: This feature is currently only supported by the UI-124x/UI-324x/UI-524x and UI-125x/UI-325x/UI-525x models. |
Methods
Method |
Description |
---|---|
Returns the current manual gain of the Log mode. |
|
Returns the default settings for the manual gain for the Log mode. |
|
Returns the range for the manual gain of the Log mode. |
|
Sets the manual gain of the Log mode. |