WL4SLG-3P3232H Miniature photoelectric sensors – SICK Sensor

$ 299.86

SKU: SICK 1068109

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1068109
Photoelectric Sensor Model:WL4SLG-3P3232H
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric retro-reflective sensor, autocollimation
Dimensions (W x H x D) 15.3 mm x 63.2 mm x 22.2 mm
Housing design Hygiene 1)
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 0 m … 4.5 m 2)

3)

Sensing range 0 m … 2 m 2)

3)

Type of light Visible red light
Light source Laser 4)
Light spot size (distance) Ø 1 mm (500 mm)
Wave length 650 nm
Laser class 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11)
Adjustment Single teach-in button
Special applications Hygienic and washdown zones, Detecting transparent objects, Detecting small objects
  • 1) Difference between standard/washdown and hygiene: The essential difference between a standard/washdown product and a hygiene product is that where the process and contact with the medium (activity in the vicinity of the food) are concerned, a hygiene product is designed in accordance with the latest standards and hygiene design guidelines, and materials are selected accordingly.
  • 2) Reflective tape REF-AC1000.
  • 3) To ensure reliable operation, we recommend using REF-AC1000 reflective tape or reflective-tap reflectors such as P41F, PLV14-A, PLH25-M12, or PLH25-D12. Reflectors with large-scale triple structures must only be used if deemed suitable for the application.
  • 4) Average service life: 50,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ≤ 100 mA
Response time ≤ 0.5 ms 5)
Switching frequency 1,000 Hz 6)
Connection type Cable with M8 male connector, 4-pin, 150 mm 7) 8)
Mechanical connection M12 adapter thread
Cable material PVC
Conductor cross-section 0.14 mm²
Circuit protection 9)

10)

11)

Protection class III
Weight 140 g
Polarisation filter
Housing material Stainless steel, Stainless steel V4A (1.4404, 316L)
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

IP68

IP69K 12)

Special feature Detecting transparent objects, M12 adapter thread
Ambient operating temperature –10 °C … +50 °C
Ambient operating temperature extended –30 °C … +55 °C 13) 14)
Ambient storage temperature –30 °C … +70 °C
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Q = light switching.
  • 5) Signal transit time with resistive load.
  • 6) With light/dark ratio 1:1.
  • 7) Max. tightening torque: 0.6 Nm.
  • 8) Do not bend below 0 °C.
  • 9) A = VS connections reverse-polarity protected.
  • 10) B = inputs and output reverse-polarity protected.
  • 11) C = interference suppression.
  • 12) Only in case of correctly mounted IP69K connecting cable.
  • 13) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
  • 14) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.

Safety-related parameters

MTTFD 647 years (EN ISO 13849-1) 1)
DCavg 0%
  • 1) Mode of calculation: Parts-Count-calculation.