WT2F-P270 Miniature Photoelectric Sensors – SICK Sensor
$ 143.00
SKU: SICK 6030589
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:6030589
Photoelectric Sensor Model:WT2F-P270
OEM Spec Ref
Features
Sensor/ detection principle | Photoelectric proximity sensor, Energetic |
Dimensions (W x H x D) | 14 mm x 19.5 mm x 3.5 mm |
Housing design (light emission) | Rectangular |
Sensing range max. | 1 mm … 9 mm 1) |
Sensing range | 1 mm … 9 mm 1) |
Type of light | Visible red light |
Light source | LED 2) |
Wave length | 660 nm |
Adjustment | None |
- 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
- 2) Average service life: 100,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 12 V DC … 24 V DC 1) |
Ripple | < 5 Vpp 2) |
Switching output | PNP |
Switching mode | Light switching |
Signal voltage PNP HIGH/LOW | Approx. VS – 1.8 V / 0 V |
Signal voltage NPN HIGH/LOW | Approx. VS / < 1.8 V |
Output current Imax. | ≤ 50 mA |
Response time | ≤ 0.5 ms 3) |
Switching frequency | 1,000 Hz 4) |
Connection type | Cable with connector M8, 3-pin, 200 mm 5) |
Cable material | PVC |
Cable diameter | Ø 2.4 mm |
Circuit protection | A 6)
C 7) D 8) |
Weight | 20 g |
Reverse polarity protection | ✔ |
Short-circuit protection | ✔ |
Housing material | Plastic, PC |
Optics material | Plastic, PC |
Enclosure rating | IP67 |
Ambient operating temperature | –20 °C … +55 °C |
Ambient temperature, storage | –40 °C … +75 °C |
- 1) +- 10 %.
- 2) May not exceed or fall below Uv tolerances.
- 3) Signal transit time with resistive load.
- 4) With light/dark ratio 1:1.
- 5) Do not bend below 0 °C.
- 6) A = VS connections reverse-polarity protected.
- 7) C = interference suppression.
- 8) D = outputs overcurrent and short-circuit protected.
Safety-related parameters
MTTFD | 1,526 years |
DCavg | 0 % |