WL4SLC-3P2232A72 Miniature Photoelectric Sensors – SICK Sensor
$ 332.64
SKU: SICK 1098509
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number:1098509
Photoelectric Sensor Model:WL4SLC-3P2232A72
OEM Spec Ref
Features
Sensor/ detection principle | Photoelectric retro-reflective sensor, autocollimation |
Dimensions (W x H x D) | 12.2 mm x 41.8 mm x 17.3 mm |
Housing design (light emission) | Rectangular |
Mounting hole | M3 |
Sensing range max. | 0 m … 12 m 1) |
Sensing range | 0 m … 8 m 1) |
Type of light | Visible red light |
Light source | Laser 2) |
Light spot size (distance) | Ø 1 mm (500 mm) |
Wave length | 650 nm |
Laser class | 1 (EN 60825-1:2014, IEC 60825-1:2014 / CDRH 21 CFR 1040.10 & 1040.11) |
Adjustment | IO-Link
Single teach-in button |
Diagnosis | Device contamination monitoring, Quality of teach-in |
Required accessories | Auxiliary sensor (e.g. WL4SL-3P2232, 1061561), Smart-Sensor Y-junction SYL-8204-G0M11-X2 (6055012), 2 x connecting cable (e.g. YF8U14-C60VA3M8U14, 2096612), 2 x reflector (e.g. P250F, 5308843) |
- 1) Reflector PL80A.
- 2) Average service life: 50,000 h at TU = +25 °C.
Mechanics/electronics
Supply voltage | 10 V DC … 30 V DC 1) |
Ripple | < 5 Vpp 2) |
Current consumption | 30 mA 3) |
Switching output | PNP 4) |
Output function | Complementary |
Switching mode | Light/dark switching 4) |
Output current Imax. | ≤ 100 mA |
Response time | ≤ 0.5 ms 5) |
Response time Q/ on Pin 2 | 300 µs … 450 µs 5) 6) |
Switching frequency | 1,000 Hz 7) |
Switching frequency Q / to pin 2 | 1,000 Hz 8) |
Connection type | Male connector M8, 4-pin |
Circuit protection | A 9)
B 10) C 11) |
Protection class | III |
Weight | 100 g |
Polarisation filter | ✔ |
Housing material | Plastic, Novodur |
Optics material | Plastic, PMMA |
Enclosure rating | IP66
IP67 |
Ambient operating temperature | –10 °C … +50 °C |
Ambient operating temperature extended | –30 °C … +55 °C 12) 13) |
Ambient temperature, storage | –30 °C … +70 °C |
UL File No. | NRKH.E181493 |
Repeatability Q/ on Pin 2: | 150 µs 6) |
- 1) Limit values when operated in short-circuit protected network: max. 8 A.
- 2) May not exceed or fall below Uv tolerances.
- 3) Without load.
- 4) Q = light switching.
- 5) Signal transit time with resistive load.
- 6) Valid for Q on Pin2, if configured with software.
- 7) With light/dark ratio 1:1.
- 8) With light / dark ratio 1:1, valid for Q on Pin2, if configured with software.
- 9) A = VS connections reverse-polarity protected.
- 10) B = inputs and output reverse-polarity protected.
- 11) C = interference suppression.
- 12) As of Ta = 50 °C, a max. supply voltage Vmax. = 24 V and a max. load current Imax. = 50 mA is permitted.
- 13) Operation below Tu –10 °C is possible if the sensor is already switched on at Tu > –10 °C, then cools down, and the supply voltage is subsequently not switched off. Switching on below Tu –10 °C is not permissible.
Safety-related parameters
MTTFD | 723 years (EN ISO 13849-1) 1) |
- 1) Mode of calculation: Parts-Count-calculation.
Communication interface
Communication interface | IO-Link V1.1 |
Communication Interface detail | COM2 (38,4 kBaud) |
Cycle time | 2.3 ms |
Process data length | 16 Bit |
Process data structure | Bit 0 = switching signal QL1
Bit 1 = Detection signal Qint.1 Bit 2 … 15 = measuring value |
VendorID | 26 |
DeviceID HEX | 0x800222 |
DeviceID DEC | 8389154 |
Smart Task
Smart Task name | Speed and Length Monitoring | ||||
Measurement mode | Speed
Length Length incremental |
||||
Relative measurement error related to the measured value | ≤ 1 % | ||||
Resolution measurement value | 1 mm / 1 mm/s | ||||
Logic function | WINDOW | ||||
Timer function | Impulse width, impulse shift | ||||
Max. pulse frequency at the external input (pin 2 / white wire) | ≤ 1,000 Hz | ||||
|
|||||
Measuring value | Speed measurement value / length measurement value |