1. Counting separated components on a guide
A component guide can present separated opaque parts in front of the sensor while a more distant machine surface remains behind them. The sensing-range potentiometer establishes the working distance, and background suppression separates that target zone from the farther background. External counting logic evaluates the PNP state after checking actual part reflectance, spacing and speed against the range, response and switching-frequency specifications.
Problem Solved
A component-passage reference helps external counting logic track separated parts from one mounting side, using an adjusted target zone that suppresses a more distant background.
Component counting
Background suppression
Range adjustment
2. Checking an insert in an assembly nest
An assembly nest can present an expected insert closer to the sensor than the empty nest surface. The sensing-range potentiometer establishes a detection distance between those positions, with background suppression evaluating the nearby target zone. External inspection logic samples the switching state when the assembly is seated, after checking actual insert reflectance, placement tolerance and separation from the background.
Problem Solved
An insert-present reference helps external inspection logic distinguish a loaded nest from an empty location, supporting a missing-component check before the next assembly operation.
Insert presence
Assembly inspection
Target zone
3. Confirming a carrier at a transfer stop
A transfer stop can bring a defined carrier surface into the sensor’s adjusted target zone while the machine structure lies farther away. The light/dark rotary switch selects the output behavior used by external transfer logic. M3 threaded mounting holes support positioning, and setup checks seated gap and carrier reflectance against the shorter gray and black target ranges where relevant.
Problem Solved
A seated-carrier reference helps external transfer logic coordinate release at a defined stop, using proximity detection from one mounting side and a locally adjusted target zone.
Carrier arrival
Light/dark selection
M3 mounting