SICK 1048124 WLG4S-3E1134H NPN Hygiene Glass Sensor

SICK 1048124 WLG4S-3E1134H NPN Hygiene Glass Sensor

USD 72.54

WLG4S-3E1134H offers polarized glass detection, 0–3 m with PL80A, NPN dark switching, a 2 m PVC cable and a stainless hygiene housing.

SKU: SICK-1048124 Category:
SICK W4S-3 Inox Hygiene Glass

SICK WLG4S-3E1134H Hygiene Glass Sensor

BrandSICK
Model IdentifierWLG4S-3E1134H
Official Part Number1048124

Technical Overview

The SICK WLG4S-3E1134H detects transparent objects using polarized coaxial retro-reflective optics with a reflector. Its specified PL80A sensing range is 0–3 m, with a 0–5 m maximum and detectable beam attenuation greater than 8%. The 650 nm PinPoint LED produces a typical 45 mm spot at 1.5 m. The NPN circuit provides dark switching and a white external teach-in input; external cable teach-in and one local teach button supports sensitivity setup. Response is below 0.5 ms with resistive load and switching frequency is 1,000 Hz at a 1:1 light/dark ratio. A 2 m pvc four-wire cable connects the 10–30 V DC electronics. The V4A stainless-steel hygiene housing has a PMMA screen and IP66/IP67/IP68/IP69K protection.

Polarized hygiene glass sensor, 0–3 m with PL80A, NPN dark switching, white external teach-in input, 2 m pvc four-wire cable and V4A stainless housing.

Key Features

  • Polarized coaxial/autocollimation retro-reflective sensing
  • 0–3 m sensing range; maximum 0–5 m with PL80A reflector
  • 650 nm PinPoint LED; typical Ø45 mm spot at 1.5 m
  • Transparent targets at >8% beam attenuation; AutoAdapt
  • NPN dark switching, ≤100 mA; white external teach-in input
  • External cable teach-in and one local teach button
  • <0.5 ms response under resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 2 m PVC four-wire cable
  • V4A stainless steel 1.4404/316L housing; PMMA front screen
  • Hygiene design; IP66/IP67/IP68/IP69K; 10–30 V DC, 30 mA without load

Detect transparent targets through taught beam attenuation and provide NPN process signals from a V4A stainless-steel hygiene housing.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensing with polarized autocollimation/coaxial optics; reflector required
Sensing range0–3 m with PL80A reflector
Maximum sensing range0–5 m with PL80A reflector
Reflector minimum distanceNo reflector minimum distance with coaxial optics
Polarization filterYes
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeTypically Ø45 mm at 1.5 m
LED service lifeAverage 100,000 h at ambient +25 °C
Attenuation along beam>8%
AutoAdaptYes
Digital outputNPN; maximum output current ≤100 mA
Switching modeDark switching
Power supply10–30 V DC; short-circuit protected supply network, maximum 8 A
Current consumption30 mA without load
Residual ripple<5 Vpp; remain within supply limits
Protection classIII
Circuit protectionSupply, inputs and output reverse-polarity protection; interference suppression
Housing designSlim rectangular; Hygiene
Housing materialV4A stainless steel, 1.4404/316L
Front screenPMMA plastic
IP ratingIP66/IP67/IP68/IP69K
Operating temperature−30 to +60 °C; extended −30 to +70 °C at supply ≤24 V and output current <30 mA
Storage temperature−30 to +75 °C
Physical Weight (kg)0.08
Response time<0.5 ms; resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Teach-in modesGlass: button >2 and <5 s toward unobstructed reflector, automatic threshold adaptation; fixed 50% threshold: >8 s toward reflector, no adaptation; maximum sensitivity: >8 s into open space, no adaptation
Cable handlingDo not bend below 0 °C
MTTFD1,215 years
DCavg0%
Mission time20 years
Connection2 m PVC four-wire cable
AdjustmentExternal cable teach-in and one local teach button
Cable assignmentBN brown=L+; BU blue=M; BK black=Q; WH white=Teach
External teach inputWhite wire to M for a pulse >2 s (NPN); exact-mode sensitivity timing per operating instructions
Cable conductor cross-section0.14 mm²

Industrial Applications

1. Counting transparent containers on a packaging conveyor

A packaging conveyor can align the sensor with a PL80A reflector across the container path. The sensor evaluates the reduced returned light as separated transparent containers cross the beam. External counting logic records the switching transitions. Actual wall material, container shape, attenuation, alignment and available gaps are validated within the 0–3 m sensing range.

Problem Solved

Beam-attenuation events provide external counting logic with a reference for separated transparent containers, helping track product flow where a transparent wall may transmit much of the emitted light.

Transparent containers PL80A reflector NPN transitions

2. Recognizing a break in a transparent material web

A material feeder can route a transparent web across the optical path between the sensor and reflector. The sensor distinguishes the attenuated web-present state from the unobstructed reflector return when a break opens the path. External line control evaluates the change against the expected material state, with actual film attenuation, flutter and the selected sensitivity validated during setup.

Problem Solved

A change from the taught material-present return to the clear reflector return identifies a possible web break, allowing external feeder control to respond before subsequent processing runs without material.

Web continuity Beam attenuation External line control

3. Identifying container accumulation at a transfer point

At a conveyor transfer, a transparent container that stays in the optical path can maintain an attenuated reflector return. External control evaluates how long the selected NPN state persists to distinguish a passing container from sustained occupancy. The actual container attenuation is validated above 8%, and the PL80A reflector is positioned within the specified sensing range.

Problem Solved

Sustained beam attenuation provides external conveyor control with an occupied-transfer indication, helping it coordinate upstream release when a container remains at the transfer instead of clearing normally.

Sustained occupancy External timing Container flow