SICK 1048118 WL4S-3V3232H PNP Retro-reflective Hygiene Sensor

SICK 1048118 WL4S-3V3232H PNP Retro-reflective Hygiene Sensor

USD 83.20

WL4S-3V3232H offers polarized reflector-based sensing, 0–3 m with PL80A, PNP dark switching, an alarm output and a 150 mm M8 lead.

Out of stock

SKU: SICK-1048118 Category:
SICK W4S-3 Inox Hygiene

SICK WL4S-3V3232H PNP Retro-reflective Hygiene Sensor

BrandSICK
Model IdentifierWL4S-3V3232H
Official Part Number1048118

Technical Overview

The SICK WL4S-3V3232H detects objects by evaluating the returned light from a reflector with polarized coaxial retro-reflective optics. Its specified PL80A sensing range is 0–3 m, with a 0–5 m maximum range and no reflector minimum distance. A 650 nm PinPoint LED produces a typical 45 mm spot at 1.5 m. A PNP dark-switching output and separate alarm provide process and warning signals, with response below 0.5 ms under resistive load and 1,000 Hz switching at a 1:1 light/dark ratio. A local teach-in button supports sensitivity adjustment. A 150 mm PVC lead with an M8 four-pin connector connects the 10–30 V DC electronics. The V4A stainless-steel hygiene housing has a PMMA screen and IP66/IP67/IP68/IP69K protection.

Polarized retro-reflective hygiene sensor, 0–3 m with PL80A, PNP dark-switching output, separate alarm, local teach button and 150 mm M8 four-pin lead.

Key Features

  • Polarized coaxial/autocollimation retro-reflective sensing
  • 0–3 m sensing range; maximum 0–5 m with PL80A reflector
  • 650 nm red PinPoint LED; typical Ø45 mm spot at 1.5 m
  • Single local teach-in button for sensitivity adjustment
  • PNP dark-switching output with separate alarm on pin 2; ≤100 mA
  • <0.5 ms response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 150 mm PVC lead with M8 four-pin connector; maximum connector torque 0.6 Nm
  • V4A stainless steel 1.4404/316L housing; PMMA screen
  • Hygiene design; IP66/IP67/IP68/IP69K
  • 10–30 V DC; 30 mA without load; protection class III

Provide an opaque-target interruption signal and a separate alarm connection to external control from a stainless-steel hygiene sensor.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensing with polarized autocollimation/coaxial optics; reflector required
Sensing range0–3 m with PL80A reflector
Maximum sensing range0–5 m with PL80A reflector
Reflector minimum distanceNo reflector minimum distance with coaxial optics
Polarization filterYes
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeTypically Ø45 mm at 1.5 m
LED service lifeAverage 100,000 h at ambient +25 °C
Digital outputPNP; maximum output current ≤100 mA
Switching modeDark switching
Power supply10–30 V DC; short-circuit protected supply network, maximum 8 A
Current consumption30 mA without load
Residual ripple<5 Vpp; remain within supply limits
Protection classIII
Circuit protectionSupply, inputs and output reverse-polarity protection; interference suppression
Housing designSlim rectangular; Hygiene
Housing materialV4A stainless steel, 1.4404/316L
Front screenPMMA plastic
IP ratingIP66/IP67/IP68/IP69K
Operating temperature−30 to +60 °C; extended −30 to +70 °C at supply ≤24 V and output current <30 mA
Storage temperature−30 to +75 °C
Physical Weight (kg)0.05
Response time<0.5 ms; resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Cable handlingDo not bend below 0 °C
MTTFD1,530 years
DCavg0%
Mission time20 years
Connection150 mm PVC cable with M8 male four-pin connector
AdjustmentSingle teach-in button
Pin assignment1 BN=L+; 3 BU=M; 4 BK=Q; 2 WH=Alarm
Alarm outputSeparate alarm output on pin 2 / white wire (CD-107)
Connector tightening torqueMaximum 0.6 Nm for M8 connector

Industrial Applications

1. Counting opaque packs on a conveyor

A conveyor can align the sensor with a PL80A reflector across the path of separated opaque packs. Each pack interrupts the returned light and changes the PNP dark-switching signal for external counting logic. The reflector stays within the 0–3 m sensing range, while pack size, beam coverage and the available clear gap are checked against the installed optical geometry and switching requirements.

Problem Solved

A blocked-versus-clear reflector return supplies external counting logic with a passage reference for opaque packs, helping track product flow without relying on light reflected by each pack surface.

Opaque packs PL80A reflector PNP signals

2. Recognizing an occupied conveyor transfer

A conveyor transfer can position the sensor and reflector across an expected load location. A load that remains in the beam maintains the interrupted-return state; external control evaluates that state over time to coordinate upstream release. Coaxial optics permit alignment without a reflector minimum distance, and a local teach button supports sensitivity setup at this sensing point.

Problem Solved

Sustained interruption provides external conveyor control with an occupied-location indication, helping coordinate the next load release when a transfer position remains blocked instead of clearing normally.

Transfer occupancy External timing Local teach-in

3. Detecting a break in an opaque material web

A material feeder can place an opaque paper or similar web between the sensor and a PL80A reflector. The normal web blocks the return; a break exposes the reflector and changes the PNP signals. External feeder control compares the signal with the expected web-present state, with web width, flutter and actual beam coverage established within the specified reflector sensing range.

Problem Solved

A change from blocked to clear return identifies a possible loss of opaque material, allowing external feeder control to recognize a web break before downstream processing continues without the expected material.

Opaque web Continuity detection Reflector return