Technical Overview

The SICK WL4S-3P3232H detects objects by evaluating the returned light from a reflector with polarized coaxial retro-reflective optics. Its specified PL80A sensing range is 0–3 m, with a 0–5 m maximum range and no reflector minimum distance. A 650 nm PinPoint LED produces a typical 45 mm spot at 1.5 m. Complementary PNP signals provide light/dark switching, with response below 0.5 ms under resistive load and 1,000 Hz switching at a 1:1 light/dark ratio. A local teach-in button supports sensitivity adjustment. A 150 mm PVC lead with an M8 four-pin connector connects the 10–30 V DC electronics. The V4A stainless-steel hygiene housing has a PMMA screen and IP66/IP67/IP68/IP69K protection.

Polarized retro-reflective hygiene sensor, 0–3 m with PL80A, complementary PNP outputs, local teach-in and 150 mm M8 four-pin lead.

Key Features

  • Polarized coaxial/autocollimation retro-reflective sensing
  • 0–3 m sensing range; maximum 0–5 m with PL80A reflector
  • 650 nm red PinPoint LED; typical Ø45 mm spot at 1.5 m
  • Single local teach-in button for sensitivity adjustment
  • Complementary PNP light/dark switching; ≤100 mA
  • <0.5 ms response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • 150 mm PVC lead with M8 four-pin connector; connector torque ≤0.6 Nm
  • V4A stainless steel 1.4404/316L housing; PMMA screen
  • Hygiene design; IP66/IP67/IP68/IP69K
  • 10–30 V DC; 30 mA without load; protection class III

Use a reflector return to distinguish object interruption states with complementary PNP signals from a stainless-steel hygiene housing.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensing with polarized autocollimation/coaxial optics; reflector required
Sensing range0–3 m with PL80A reflector
Maximum sensing range0–5 m with PL80A reflector
Reflector minimum distanceNo reflector minimum distance with coaxial optics
Polarization filterYes
Light sourceVisible red PinPoint LED
Wavelength650 nm
Light spot sizeTypically Ø45 mm at 1.5 m
LED service lifeAverage 100,000 h at ambient +25 °C
Digital outputPNP; maximum output current ≤100 mA
Switching modeLight/dark switching; complementary
Power supply10–30 V DC; short-circuit protected supply network, maximum 8 A
Current consumption30 mA without load
Residual ripple<5 Vpp; remain within supply limits
Protection classIII
Circuit protectionSupply, inputs and output reverse-polarity protection; interference suppression
Housing designSlim rectangular; Hygiene
Housing materialV4A stainless steel, 1.4404/316L
Front screenPMMA plastic
IP ratingIP66/IP67/IP68/IP69K
Operating temperature−30 to +60 °C; extended −30 to +70 °C at supply ≤24 V and output current <30 mA
Storage temperature−30 to +75 °C
Physical Weight (kg)0.05
Response time<0.5 ms; resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Cable handlingDo not bend below 0 °C
MTTFD1,530 years
DCavg0%
Mission time20 years
Connection150 mm PVC lead with an M8 four-pin connector
AdjustmentSingle teach-in button
Pin assignment1 BN=L+; 3 BU=M; 4 BK=Q; 2 WH=/Q
Connector tightening torqueMaximum 0.6 Nm for M8 connector

Industrial Applications

1. Counting opaque packs on a conveyor

A conveyor can align the sensor with a PL80A reflector across the path of separated opaque packs. Each pack interrupts the returned light and changes the complementary PNP states for external counting logic. The reflector stays within the 0–3 m sensing range, while pack size, beam coverage and the available clear gap are checked against the installed optical geometry and switching requirements.

Problem Solved

A blocked-versus-clear reflector return supplies external counting logic with a passage reference for opaque packs, helping track product flow without relying on light reflected by each pack surface.

Opaque packs PL80A reflector PNP signals

2. Recognizing an occupied conveyor transfer

A conveyor transfer can position the sensor and reflector across an expected load location. A load that remains in the beam maintains the interrupted-return state; external control evaluates that state over time to coordinate upstream release. Coaxial optics permit alignment without a reflector minimum distance, and a local teach button supports sensitivity setup at this sensing point.

Problem Solved

Sustained interruption provides external conveyor control with an occupied-location indication, helping coordinate the next load release when a transfer position remains blocked instead of clearing normally.

Transfer occupancy External timing Local teach-in

3. Detecting a break in an opaque material web

A material feeder can place an opaque paper or similar web between the sensor and a PL80A reflector. The normal web blocks the return; a break exposes the reflector and changes the PNP signals. External feeder control compares the signal with the expected web-present state, with web width, flutter and actual beam coverage established within the specified reflector sensing range.

Problem Solved

A change from blocked to clear return identifies a possible loss of opaque material, allowing external feeder control to recognize a web break before downstream processing continues without the expected material.

Opaque web Continuity detection Reflector return