SICK 1015852 WL24-2B230 PNP/NPN Retro-reflective Sensor

SICK 1015852 WL24-2B230 PNP/NPN Retro-reflective Sensor

USD 208.26

WL24-2B230 offers polarized red-light retro-reflective sensing to 15 m with PL80A, selectable PNP/NPN and light/dark output, and a sender test input.

SKU: SICK-1015852 Category:
SICK W24-2

SICK WL24-2B230 Selectable PNP/NPN Retro-reflective Sensor

BrandSICK
Model IdentifierWL24-2B230
Official Part Number1015852

Technical Overview

The SICK WL24-2B230 is a polarized photoelectric retro-reflective sensor that receives its red LED beam from a passive reflector. With PL80A, the specified ranges are 0.03–15 m sensing and 0.03–22 m maximum range, retaining the minimum distance required by its dual-lens optics. A potentiometer adjusts sensitivity, with separate PNP/NPN and light/dark selectors matching the output to compatible control. Response is no more than 500 µs with resistive load and switching frequency is 1,000 Hz at a 1:1 light/dark ratio. The device uses 10–30 V DC and M16-gland terminal wiring, with a sender-off test input, zinc die-cast housing, PMMA optics and IP67 protection.

Polarized red-light retro-reflective sensor with PL80A sensing to 15 m, selectable PNP/NPN and light/dark output, sender test input and M16-gland terminals.

Key Features

  • Polarized red-light retro-reflective sensing with minimum-distance dual-lens optics
  • PL80A: 0.03–15 m sensing; 0.03–22 m maximum range
  • Red LED; Ø250 mm spot at 15 m
  • Sensitivity potentiometer, alignment sight and LED signal-strength indicator
  • PNP/NPN selector and separate light/dark selector
  • ≤500 µs response with resistive load; 1,000 Hz at 1:1 light/dark ratio
  • Sender-off test input: TE to 0 V
  • 10–30 V DC; ≤100 mA output current; M16-gland terminal wiring
  • M5 mounting; zinc die-cast housing; PMMA optics; IP67; −40 to +60 °C operation

Monitor a returned optical beam across a process path and select PNP/NPN and light/dark behavior for the connected control input.

Technical Specification Matrix

ParameterValue
Functional principlePolarized photoelectric retro-reflective sensor; dual-lens optics require minimum reflector distance
Sensing range0.03–15 m with PL80A reflector
Maximum sensing range0.03–22 m with PL80A reflector
Light sourceVisible red LED; average service life 100,000 h at +25 °C
Light spot sizeØ250 mm at 15 m
AdjustmentSensitivity potentiometer
Switching outputPNP or NPN, selected by changeover selector
Switching modeLight/dark switching, separately selectable
Output current≤100 mA
Response time≤500 µs signal transit time with resistive load
Switching frequency1,000 Hz at 1:1 light/dark ratio
Power supply10–30 V DC; limit values in short-circuit protected network maximum 8 A
Ripple<5 Vpp; remain within supply-voltage tolerances
Current consumption50 mA without load
ConnectionTerminal connection through M16 gland; gland arrangement rotatable by 90°
Terminal assignmentCD-120: 1=L+; 2=M; 4=Q/Q complement according to selected switching mode; 5=Test
Sender test inputTE to 0 V switches sender off
Circuit protectionSupply reverse-polarity protection; interference suppression; output overcurrent and short-circuit protection
Protection classII; reference voltage 50 V DC
MountingM5 threaded mounting hole, 6 mm deep; M5 threaded through-hole
IndicatorsAlignment sight and LED signal-strength indicator
Housing materialZinc die-cast metal
Optics materialPMMA plastic
IP ratingIP67
Operating temperature−40 to +60 °C
Storage temperature−40 to +75 °C
MTTFD431 years
Diagnostic coverageDCavg 0%
Polarization filterYes
Reflector-specific rangesPL80A: 0.03–15 m sensing / 0.03–22 m maximum; PL50A/PL40A: 0.03–11 / 0.03–16 m; PL30A/PL20A/Diamond Grade tape: 0.03–7 / 0.03–10 m; C110A: 0.15–10 / 0.15–13 m
UL filesNRKH.E181493 and NRKH7.E181493
Physical Weight (kg)0.33

Industrial Applications

1. Counting separated loads across a conveyor

A conveyor can place the sensor opposite a passive reflector so separated opaque loads interrupt the returned red beam. External counting logic reads the selected PNP or NPN output with the chosen light/dark behavior. Commissioning checks the reflector-specific range, optical alignment, load gaps and transit timing against the documented response and switching-frequency conditions.

Problem Solved

A beam-interruption reference helps external counting logic register separated loads across the conveyor, using a selected output type and verified reflector arrangement for the installed path.

Load counting Passive reflector Selectable output

2. Monitoring opaque material continuity on a feed

An opaque material feed can pass between the sensor and a compatible reflector, keeping the returned beam interrupted while material is present. A gap or runout changes the received-light condition for external feed monitoring. Setup selects sensitivity and light/dark behavior, then verifies the actual reflector separation, material coverage and smallest interruption that the process must recognize.

Problem Solved

A changed optical-path condition helps external feed monitoring identify missing material at the sensing point, using commissioned sensitivity, reflector geometry and selected switching behavior.

Material continuity Gap detection External monitoring

3. Checking the optical switching path during commissioning

Commissioning logic can apply 0 V to the sender test input to switch off the red beam and observe the resulting process-input state. Setup uses the documented terminal assignment and selected PNP/NPN and light/dark behavior. Restoring the normal test-input condition and verifying a clear reflected path exercises the sensor’s optical switching response and its external connection.

Problem Solved

A controlled sender-off check helps commissioning staff exercise the optical switching path and connected process input, using the documented test terminal and selected output behavior.

Sender test Commissioning Terminal checks
Select your currency