WL12G-3P3572S12 Small Photoelectric Sensors – SICK Sensor

USD $ 473.76

SKU: SICK 1053545

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:1053545
Photoelectric Sensor Model:WL12G-3P3572S12
OEM Spec Ref 

Features

Device type Photoelectric sensors
Sensor/ detection principle Photoelectric retro-reflective sensor
Dimensions (W x H x D) 15.5 mm x 48.5 mm x 42 mm
Housing design (light emission) Rectangular
Sensing range max. 0 m … 500 mm 1)
Type of light Visible red light
Light source PinPoint LED 2)
Light spot size (distance) Ø 25 mm (1.5 m)
Wave length 660 nm
Adjustment Single teach-in button
Special applications Detecting transparent objects
Special features Without continuous threshold adaption
  • 1) Reflector P250F.
  • 2) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 40 mA 3)
Switching output PNP
Output function Complementary
Switching mode Light/dark switching
Signal voltage NPN HIGH/LOW Approx. VS / < 2.5 V
Output current Imax. ≤ 100 mA
Response time ≤ 333 µs 4)
Switching frequency 1,500 Hz 5)
Connection type Male connector M12, 5-pin
Circuit protection 6)

7)

8)

9)

Protection class III
Weight 120 g
Special device
Housing material Metal, zinc diecast
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

Special feature Detecting transparent objects
Operating mode Mode I, 10 % attenuation, Mode II, 18 % attenuation
Ambient operating temperature ≤ +60 °C
Ambient temperature, storage –40 °C … +75 °C
UL File No. NRKH.E181493 & NRKH7.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) B = inputs and output reverse-polarity protected.
  • 8) C = interference suppression.
  • 9) D = outputs overcurrent and short-circuit protected.