Weidmuller WTR 4 Test-Disconnect Terminal Block

$ 1.56

Total:

Modular test-disconnect terminal block with screw connection. Features a pivoting lever, 500V/32A IEC rating, and 4mm² cross-section for TS 35 DIN rail mounting.

SKU Weidmuller-7910180000 Category
MOQ: 50 pcs   >>   Order in multiples of 50
Industrial Connectors > Terminal Blocks > Test Disconnect Terminal Blocks

Weidmüller WTR 4 Test-Disconnect Terminal Block

Model Identifier WTR 4
Official Part Number 7910180000
GTIN Standard 4008190576882

Technical Overview

The Weidmüller WTR 4 (Part No. 7910180000) is a modular test-disconnect terminal block designed for reliable circuit isolation and testing in industrial environments. Featuring a robust pivoting disconnect lever, it allows for safe voltage-free measurement and troubleshooting without removing conductors. The unit is built with a screw connection system supporting a rated cross-section of 4 mm² and is housed in dark beige Wemid thermoplastic with a UL 94 V-0 flammability rating. Rated for 500 V and 32 A (IEC), it also carries ATEX and IECEx certifications (Ex ec II C Gc) for use in hazardous areas (Zone 2).

Key Features

  • Modular test-disconnect design with pivoting lever
  • Screw connection technology for secure vibration-resistant termination
  • Rated for 500 V / 32 A (IEC) and 300 V / 10 A (UL)
  • ATEX and IECEx certified for explosive atmospheres (Ex ec II C Gc)
  • Compact 6.1 mm width compatible with TS 35 DIN rail
  • Robust Wemid construction with operating temperature up to 120 °C
  • Accommodates conductors up to 4 mm² (AWG 10)
  • Integrated test sockets for standard 2.3 mm test plugs

Pivoting test-disconnect mechanism enabling safe, tool-free circuit isolation for measurement and maintenance.

Technical Specification Matrix

Technical ParameterSpecification
Product TypeTest-disconnect terminal
Connection MethodScrew connection
Number of Levels1
Number of Connections2
Rated Cross-Section4 mm²
ColorDark beige
Insulating MaterialWemid
Flammability RatingUL 94 V-0
Depth including DIN rail49 mm
Rated Voltage (IEC)500 V
Rated Current (IEC)32 A
Current at Max. Conductor32 A
Volume Resistance1 mΩ
Power Loss1.02 W
Rated Impulse Withstand Voltage6 kV
Pollution Severity3
Surge Voltage CategoryIII
Tightening Torque0.5 - 0.6 Nm
Stripping Length13 mm
Clamping ScrewM 2.5
Continuous Operating Temp., Min.-50 °C
Continuous Operating Temp., Max.120 °C
Storage Temperature-25 °C...55 °C
ATEX Certificate No.DEMKO14ATEX1389U
IECEx Certificate No.IECEXUL14.0097U
Max. Voltage (ATEX/IECEx)400 V
Current (ATEX/IECEx)25 A
Max. Cross-Section (ATEX/IECEx)4 mm²
Marking EN 60079-7Ex ec II C Gc
Marking Ex 2014/34/EUII 3 G D
Mounting RailTS 35
Clamping Range, Rated Connection, Min.0.05 mm²
Clamping Range, Rated Connection, Max.6 mm²
Conductor Connection Cross-Section, Solid, Min.0.5 mm²
Conductor Connection Cross-Section, Solid, Max.6 mm²
Conductor Connection Cross-Section, Stranded, Min.1.5 mm²
Conductor Connection Cross-Section, Stranded, Max.6 mm²
Conductor Connection Cross-Section, Finely Stranded, Min.0.5 mm²
Conductor Connection Cross-Section, Finely Stranded, Max.4 mm²
Conductor Connection Cross-Section, Finely Stranded with Wire-End Ferrules, Min.0.5 mm²
Conductor Connection Cross-Section, Finely Stranded with Wire-End Ferrules, Max.4 mm²
Width6.1 mm
Height60 mm
Depth48 mm
Blade Size0.6 x 3.5 mm
Conductor Size (UL) Min.22 AWG
Conductor Size (UL) Max.10 AWG
Voltage Size C (UL)300 V
Current Size C (UL)20 A
Conductor Size (CSA) Min.22 AWG
Conductor Size (CSA) Max.10 AWG
Voltage Size C (CSA)300 V
Current Size C (CSA)10 A
Net Weight11.554 g

Industrial Applications

1. Signal Loop Isolation in Process Control

Utilized in DCS and PLC marshalling cabinets to manage 4-20mA analog signal loops. The terminal block allows technicians to disconnect specific sensors or actuators for calibration and testing via the integrated test sockets without physically disconnecting wires.

Problem Solved

Eliminates the risk of loose connections or short circuits during routine maintenance of sensitive analog signal paths, reducing downtime and wiring errors.

Galvanic isolationSignal marshalling4-20mA loopsTest sockets

2. Secondary Circuit Protection in Substations

Deployed in voltage transformer (VT) secondary circuits within power distribution panels. The disconnect facility provides a safe point to isolate metering and protection relays for injection testing.

Problem Solved

Ensures operator safety and prevents short circuits in VT loops during commissioning or maintenance by providing a clear, visible break point.

VT circuitsInjection testingProtection relaysSecondary injection

3. Hazardous Area Instrumentation Maintenance

Installed in Ex e / Ex ec certified junction boxes located in Zone 2 hazardous areas. The terminal facilitates the safe disconnection of field instruments for replacement or verification while maintaining compliance with explosion protection standards.

Problem Solved

Provides a certified, spark-safe disconnect method in explosive atmospheres, facilitating instrument checks without violating Zone 2 compliance.

ATEX Zone 2Ex ec II C GcExplosion protectionInstrument isolation

[Download-Datasheet]