Skip to content

Contact Us:
sales@inosaki.com

SICK 1042067 WL4S-3F3130 PNP Retro-Reflective Sensor

SICK 1042067 WL4S-3F3130 PNP Retro-Reflective Sensor

USD 141.70

Coaxial polarised red-light sensor with PNP dark switching, 1,000 Hz operation and a 100 mm M8 connection cable in a slim IP66/IP67 housing.

SKU: SICK-1042067 Category:
SICK W4S-3

SICK WL4S-3F3130 Coaxial Retro-Reflective Photoelectric Sensor

BrandSICK
Model IdentifierWL4S-3F3130
Official Part Number1042067

Technical Overview

The SICK WL4S-3F3130 is a slim polarised retro-reflective photoelectric sensor with coaxial optics and a PNP dark-switching output. Its autocollimation arrangement operates without a minimum reflector distance, allowing a reflector to be positioned close to the sensor when machine space is constrained. With a PL80A reflector, the specified sensing range is 0–2.5 m and the maximum range is 4 m. The visible red PinPoint LED produces a 45 mm spot at 1.5 m, while a response below 0.5 ms and 1,000 Hz switching support repeated detection events. A 100 mm cable with M8 3-pin connector and IP66/IP67 ABS housing support compact installations.

PNP dark-switching retro-reflective sensor with coaxial optics, no minimum reflector distance, a 100 mm M8 connection cable and IP66/IP67 housing.

Key Features

  • Coaxial/autocollimation retro-reflective optics
  • No minimum reflector distance
  • Polarisation filter for retro-reflective operation
  • 0–2.5 m sensing range; 4 m maximum with PL80A reflector
  • 650 nm visible red PinPoint LED; Ø 45 mm spot at 1.5 m
  • PNP dark-switching output
  • Response < 0.5 ms; 1,000 Hz switching frequency
  • 10–30 V DC; 20 mA current consumption without load
  • 100 mm PVC cable with M8 3-pin connector
  • Slim ABS housing with IP66/IP67 protection

Place the reflector close to the sensor with coaxial optics that eliminate the minimum reflector separation in compact machine layouts.

Technical Specification Matrix

ParameterValue
Functional principlePhotoelectric retro-reflective sensor with autocollimation/coaxial optics; no minimum reflector distance
Sensing range0–2.5 m with PL80A reflector
Maximum sensing range0–4 m with PL80A reflector
Light sourcePinPoint LED, visible red light
Wavelength650 nm
Light spot sizeØ 45 mm at 1.5 m
AdjustmentNone
Power supply10–30 V DC
Residual ripple< 5 Vpp; remain within supply-voltage limits
Current consumption20 mA, without load
Protection classIII
Switching outputPNP
Switching modeDark switching
Output current≤ 100 mA
Response time< 0.5 ms with resistive load
Switching frequency1,000 Hz at light/dark ratio 1:1
Circuit protectionSupply reverse-polarity protection, interference suppression and output overcurrent/short-circuit protection
Housing formRectangular, slim
Connection100 mm PVC cable with M8 3-pin connector
Housing materialABS plastic
Front screen materialPMMA plastic
IP ratingIP66 and IP67
Operating temperature−40 to +60 °C
Storage temperature−40 to +75 °C
MountingThreaded M3 mounting hole
IndicatorsGreen supply-voltage LED; yellow received-light indicator
MTTFD3,027 years
Diagnostic coverage DCavg0%
Mission time20 years
UL fileNRKH.E181493 & NRKH7.E181493
Physical Weight (kg)0.03
Dimensions L x W x H (cm)1.73 x 1.22 x 4.18
Polarisation filterYes
Conductor cross-section0.14 mm²
Cable diameter3.4 mm
Cable handlingDo not bend below 0 °C

Industrial Applications

1. Counting separated opaque cartons

A carton conveyor can place the sensor on one side and a passive reflector on the other. Each opaque carton interrupts the returned red beam, producing a PNP switching event for the counter. Polarised retro-reflective sensing provides the optical path, while the 1,000 Hz switching frequency supports repeated transitions within the specified timing limits.

Problem Solved

The reflector needs no electrical supply, reducing wiring across the conveyor while the machine receives a discrete event for each separated carton that interrupts the beam.

Polarised retro-reflective PNP 1,000 Hz

2. Monitoring accumulation at a transfer point

At a conveyor transfer, a load that remains between the sensor and reflector holds the received-light signal in the blocked state. The machine controller can use this duration to identify sustained occupancy and regulate upstream release. The PNP dark-switching output reports beam interruption, while the short M8 connection cable links the sensor to local machine wiring.

Problem Solved

A sustained beam blockage identifies a transfer position that remains occupied, helping the controller coordinate upstream feeding before additional loads enter the same constrained space.

Dark switching 100 mm M8 cable Beam interruption

3. Checking opaque sheet continuity

An opaque sheet feeder can direct the returned beam through the expected material path. The sensor detects whether the material continues to block that path, and an opening caused by runout or a break changes its switching state. IP67 protection suits exposed machine mounting, while the visible red beam assists positioning during initial setup.

Problem Solved

A change in the received-light state gives the controller an electrical indication of missing material at the monitoring position, supporting an orderly response to interrupted feed.

IP67 Visible red light Material continuity
Select your currency