Contact Us:
sales@inosaki.com

VTE18-4P4212 Cylindrical Photoelectric Sensors – SICK Sensor

$ 80.96

SKU N/A Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:6013261
Photoelectric Sensor Model: VTE18-4P4212
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Energetic
Dimensions (W x H x D) 18 mm x 18 mm x 63.6 mm
Housing design (light emission) Cylindrical
Housing length 63.6 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 5 mm … 400 mm 1)
Sensing range 5 mm … 350 mm
Focus Approx. 2.8°
Type of light Infrared light
Light source LED 2)
Light spot size (distance) Ø 20 mm (400 mm)
Angle of dispersion Approx. 2.8°
Adjustment Potentiometer, 270° (Sensing range)
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via L/D control cable
Output current Imax. ≤ 100 mA
Response time ≤ 2 ms 5)
Switching frequency 250 Hz 6)
Connection type Cable, 4-wire, 2 m 7)
Cable material PVC
Conductor cross-section 0.14 mm²
Cable diameter Ø 5 mm
Circuit protection 8)

9)

10)

11)

Protection class III
Weight 120 g
Housing material Metal, Nickel-plated brass
Optics material Plastic, PMMA
Enclosure rating IP67
Ambient operating temperature –25 °C … +70 °C
UL File No. NMFT2.E175606
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Control wire open: dark switching D.ON.
  • 5) Signal transit time with resistive load.
  • 6) With light/dark ratio 1:1.
  • 7) Do not bend below 0 °C.
  • 8) A = VS connections reverse-polarity protected.
  • 9) B = inputs and output reverse-polarity protected.
  • 10) C = interference suppression.
  • 11) D = outputs overcurrent and short-circuit protected.

Additional information

Related Products

PEPPERLFUCHS_Slot and Slot Grid Sensors_GL5-T-28a-155
Omron_Power Supply Units_NX-PA9001
Q4XFKLAF610-Q8
PANASONIC_Compact Inductive Proximity Sensor-GH-3SE
SICK_sensor_Distance sensor_UC12_UC12-12231
Omron_Analog Timers_H3DT-L1 ACDC24-240
Select your currency