Skip to content

Contact Us:
sales@inosaki.com

SICK 6013731 VS/VE18-4P3440 PNP Through-beam Sensor

SICK 6013731 VS/VE18-4P3440 PNP Through-beam Sensor

USD 198.12

VS/VE18-4P3440 provides 0–14 m through-beam sensing, radial infrared optics, PNP light/dark switching, 270° sensitivity adjustment and M12 connections.

SKU: SICK-6013731 Category:
SICK V18

SICK VS/VE18-4P3440 PNP Through-beam Sensor

BrandSICK
Model IdentifierVS/VE18-4P3440
Official Part Number6013731

Technical Overview

The SICK VS/VE18-4P3440 is a through-beam photoelectric sensor arrangement with separate sender and receiver, radial infrared optics and a 0–14 m sensing range. Maximum sensing range is 0–20 m, and the LED produces a 700 mm spot at 14 m. A 270° potentiometer adjusts sensitivity, while the receiver provides a PNP output with light/dark selection through its control connection; an open control connection selects dark switching. A sender test input switches illumination off when connected to 0 V. Response is no more than 2 ms with resistive load, with 250 Hz switching at a 1:1 light/dark ratio. Nickel-plated brass M18 × 1 housings have four-pin M12 connections and IP67 protection.

PNP through-beam sensor arrangement with 0–14 m range, radial infrared optics, 270° sensitivity adjustment, sender test input and M12 connections.

Key Features

  • Through-beam sensing with separate sender and receiver
  • 0–14 m sensing range; 0–20 m maximum range
  • Radial infrared LED optics; Ø700 mm spot at 14 m
  • Approximately 2.8° angle of dispersion; 270° sensitivity potentiometer
  • PNP output; light/dark selection via L/D control connection; open selects dark switching
  • Sender test input: TE to 0 V switches sender off
  • ≤2 ms response with resistive load; 250 Hz at 1:1 light/dark ratio
  • 10–30 V DC; 30 mA without load; output current ≤100 mA
  • M18 × 1 nickel-plated brass housing; M12 four-pin connections
  • IP67; protection class III; −25 to +70 °C operating temperature

Detect an opaque target interrupting the sender-to-receiver path, with adjustable sensitivity and a sender-off input for controlled signal checks.

Technical Specification Matrix

ParameterValue
Functional principleThrough-beam photoelectric sensor; separate sender and receiver
Sensing range0–14 m
Maximum sensing range0–20 m
Light sourceInfrared LED
Light spot sizeØ700 mm at 14 m
Angle of dispersionApproximately 2.8°
LED service lifeAverage 100,000 h at +25 °C ambient
Optical axisRadial
AdjustmentSensitivity potentiometer, 270°
Switching outputPNP; output current ≤100 mA
Switching modeLight/dark switching via L/D control connection; open selects dark switching
Test inputTE to 0 V switches sender off
Response time≤2 ms with resistive load
Switching frequency250 Hz at 1:1 light/dark ratio
Power supply10–30 V DC, limit values
Residual ripple±10%; remain within supply-voltage limits
Current consumption30 mA without load
ConnectionM12 four-pin male connector
Sender pin assignmentCD-219: 1 BN=L+; 2 WH=Test; 3 BU=M; 4 not connected
Receiver pin assignmentCD-219: 1 BN=L+; 2 WH=L/D; 3 BU=M; 4 BK=Q
Circuit protectionSupply/input/output reverse-polarity protection; interference suppression; output overcurrent and short-circuit protection
Protection classIII
Housing designCylindrical, M18 × 1 thread
Housing materialNickel-plated brass
Housing length75 mm
IP ratingIP67
Operating temperature−25 to +70 °C
UL fileNMFT2.E175606
MTTFD403 years
DCavg0%

Industrial Applications

1. Counting separated opaque loads across a conveyor

A conveyor can mount the sender and receiver on opposite sides of an opaque-load path and use receiver output transitions as external count events. Sensitivity adjustment establishes the optical condition at the installed separation within the specified range. Commissioning checks load coverage, clear gaps and transit timing against the response and switching-frequency limits.

Problem Solved

A beam-interruption reference lets external counting logic register separated opaque loads across a conveyor, without relying on light reflected from the changing load surface.

Load counting Through-beam path PNP output

2. Monitoring an opaque sheet for a feed interruption

A sheet feeder can route opaque material through the sender-to-receiver path so normal feed blocks the infrared beam. A break or runout exposes the receiver and changes the configured PNP signal. External feeder logic evaluates this condition using its own timing, after setup checks sheet width, flutter, optical coverage and the selected light/dark control state.

Problem Solved

A blocked-to-clear transition gives external feeder logic a reference for missing opaque material, supporting an orderly response when normal material continuity is interrupted at the monitored position.

Sheet continuity Infrared path External feeder logic

3. Checking a transfer sensor with controlled sender-off input

A transfer station can monitor a carrier through normal beam interruption, then request a sender-off check at an appropriate point in its sequence. External control applies TE to 0 V and compares the receiver signal with the expected state for the selected light/dark mode. Commissioning establishes alignment, output polarity and permissible check timing for the station.

Problem Solved

A controlled sender-off condition helps external maintenance logic compare the optical signal path with an expected response, supporting troubleshooting of the installed transfer detection arrangement.

Sender-off check Transfer detection External maintenance