UM30-214113 Ultrasonic sensors – SICK Sensor
$ 651.13
SKU: SICK 6036919
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6036919
Distance Sensor Model: UM30-214113
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 9 V … 30 V 1) 2) |
Power consumption | ≤ 2.4 W 3) |
Initialization time | < 300 ms |
Design | Cylindrical |
Housing material | Metal (nickel-plated brass, PBT)
Ultrasonic transducer: polyurethane foam, glass epoxy resin |
Thread size | M30 x 1.5 |
Connection type | Male connector, M12, 5-pin |
Indication | LED display, 2 x LED |
Weight | 210 g |
Sending axis | Straight |
Dimensions (W x H x D) | 47.5 mm x 47.5 mm x 102 mm |
Enclosure rating | IP65 / IP67 |
Protection class | III |
- 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
- 2) 15 V … 30 V when using the analog voltage output.
- 3) Without load.
Performance
Operating range, limiting range | 350 mm … 3,400 mm, 5,000 mm |
Target | Natural objects |
Resolution | ≥ 0.18 mm |
Repeatability | ± 0.15 % 1) |
Accuracy | ± 1 % 2) 3) |
Temperature compensation | ✔ |
Response time | 180 ms 4) |
Output time | 43 ms |
Ultrasonic frequency (typical) | 120 kHz |
Detection area (typical) | See diagrams |
Additional function | Teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default |
- 1) In relation to the current measured value, minimum value ≥ resolution.
- 2) Referring to current measurement value.
- 3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
- 4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
Interfaces
|
|||||||||||||||
Multifunctional input (MF) | 1 x MF |
- 1) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
Ambient data
Ambient temperature, operation | –25 °C … +70 °C |
Ambient temperature, storage | –40 °C … +85 °C |