SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6036923
Distance Sensor Model: UM30-213118
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs |
DC 9 V … 30 V 1) 2) |
Power consumption |
≤ 2.4 W 3) |
Initialization time |
< 300 ms |
Design |
Cylindrical |
Housing material |
Metal (nickel-plated brass, PBT)
Ultrasonic transducer: polyurethane foam, glass epoxy resin |
Thread size |
M30 x 1.5 |
Connection type |
Male connector, M12, 5-pin |
Indication |
LED display, 2 x LED |
Weight |
150 g |
Sending axis |
Straight |
Dimensions (W x H x D) |
30 mm x 30 mm x 84 mm |
Enclosure rating |
IP65 / IP67 |
Protection class |
III |
Performance
Operating range, limiting range |
200 mm … 1,300 mm, 2,000 mm |
Target |
Natural objects |
Resolution |
≥ 0.18 mm |
Repeatability |
± 0.15 % 1) |
Accuracy |
± 1 % 2) 3) |
Temperature compensation |
✔ |
Response time |
92 ms 4) |
Switching frequency |
8 Hz |
Output time |
23 ms |
Ultrasonic frequency (typical) |
200 kHz |
Detection area (typical) |
See diagrams |
Additional function |
Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default |
Interfaces
Digital output |
|
Number |
1 1) |
Type |
PNP |
Maximum output current IA |
≤ 200 mA |
|
Analog output |
|
Number |
1 |
Type |
Current output / voltage output |
Function |
Automatic selection of analog current or voltage output dependent on load |
Current |
4 mA … 20 mA, ≤ 500 Ω 2) |
Voltage |
0 V … 10 V, ≥ 100,000 Ω |
Resolution |
12 bit |
|
Multifunctional input (MF) |
1 x MF |
Hysteresis |
20 mm |
Ambient data
Ambient temperature, operation |
–25 °C … +70 °C |
Ambient temperature, storage |
–40 °C … +85 °C |