UM30-211112 Ultrasonic sensors – SICK Sensor
$ 525.60
SKU: SICK 6037664
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6037664
Distance Sensor Model: UM30-211112
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 9 V … 30 V 1) |
Power consumption | ≤ 2.4 W 2) |
Initialization time | < 300 ms |
Design | Cylindrical |
Housing material | Metal (nickel-plated brass, PBT)
Ultrasonic transducer: polyurethane foam, glass epoxy resin |
Thread size | M30 x 1.5 |
Connection type | Male connector, M12, 5-pin |
Indication | LED display, 2 x LED |
Weight | 150 g |
Sending axis | Straight |
Dimensions (W x H x D) | 30 mm x 30 mm x 84 mm |
Enclosure rating | IP65 / IP67 |
Protection class | III |
- 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
- 2) Without load.
Performance
Operating range, limiting range | 30 mm … 250 mm, 350 mm |
Target | Natural objects |
Resolution | ≥ 0.18 mm |
Repeatability | ± 0.15 % 1) |
Accuracy | ± 1 % 2) 3) |
Temperature compensation | ✔ |
Response time | 32 ms |
Switching frequency | 25 Hz |
Output time | 8 ms |
Ultrasonic frequency (typical) | 320 kHz |
Detection area (typical) | See diagrams |
Additional function | Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default |
- 1) In relation to the current measured value, minimum value ≥ resolution.
- 2) Referring to current measurement value.
- 3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
Interfaces
|
|||||||||
Multifunctional input (MF) | 1 x MF | ||||||||
Hysteresis | 3 mm |
- 1) PNP: HIGH = VS – (< 2 V) / LOW = 0 V.
Ambient data
Ambient temperature, operation | –25 °C … +70 °C |
Ambient temperature, storage | –40 °C … +85 °C |