Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my
Fuse modular terminal block, fuse type: Glass / ceramics / …, number of positions: 1, connection method: Screw connection, cross section: 0.2 mm²- 4 mm², AWG: 24 – 12, nominal current: 6.3 A, nom. voltage: 800 V, width: 8.2 mm, fuse type: G / 5 x 20 / 5 x 25 / 5 x 30, mounting type: NS 35/7,5, NS 35/15, NS 32, color: black
General
Note |
For terminal marking, please use marking material with 8.2 mm pitch. |
|
For lever marking, please use marking material with 6.2 mm pitch. |
Article Number |
3004100 |
Number of levels |
1 |
Number of connections |
2 |
Nominal cross section |
4 mm² |
Color |
black |
Insulating material |
PA |
Flammability rating according to UL 94 |
V0 |
Rated surge voltage |
8 kV |
Rated operating voltage |
250 V |
Degree of pollution |
3 |
Overvoltage category |
III |
Insulating material group |
I |
Connection in acc. with standard |
IEC 60947-7-3 |
Maximum load current |
6.3 A (the current is determined by the fuse used) |
Nominal current IN |
6.3 A |
Nominal voltage UN |
800 V (As a fuse terminal block) |
Fuse |
G / 5 x 20 / 5 x 25 / 5 x 30 |
Fuse type |
Glass / ceramics / … |
Open side panel |
No |
Number of positions |
1 |
Shock protection test specification |
DIN EN 50274 (VDE 0660-514):2002-11 |
Back of the hand protection |
guaranteed |
Finger protection |
guaranteed |
Note |
Swing the locking lever to its final position before replacing the fuse. |
Result of surge voltage test |
Test passed |
Surge voltage test setpoint |
9.8 kV |
Result of power-frequency withstand voltage test |
Test passed |
Power frequency withstand voltage setpoint |
2 kV |
Result of tight fit on support |
Test passed |
Contact resistance |
Test passed |
Compatibitity between modular fuse terminal block and fuse insert |
Test passed |
Actuatiing forces on plug in or lever in fuse insert carriers |
Test passed |
Result of the test for mechanical stability of terminal points (5 x conductor connection) |
Test passed |
Result of flexion and pull-out test |
Test passed |
Bending test rotation speed |
10 rpm |
Bending test turns |
135 |
Bending test conductor cross section/weight |
0.2 mm² / 0.2 kg |
|
4 mm² / 0.9 kg |
Testing the rated value of the power dissipation (overload and short circuit Protection) |
Test passed |
Testing the rated value of the power dissipation (exclusively short circuit protection) |
Test passed |
Result of temperature-rise test |
Test passed |
Result of thermal test |
Test passed |
Oscillation, broadband noise test result |
Test passed |
Test specification, oscillation, broadband noise |
DIN EN 50155 (VDE 0115-200):2008-03 |
Test spectrum |
Service life test category 1, class B, body mounted |
Test frequency |
f1 = 5 Hz to f2 = 150 Hz |
ASD level |
1.857 (m/s²)²/Hz |
Acceleration |
0.8g |
Test duration per axis |
5 h |
Test directions |
X-, Y- and Z-axis |
Shock test result |
Test passed |
Test specification, shock test |
DIN EN 50155 (VDE 0115-200):2008-03 |
Shock form |
Half-sine |
Acceleration |
5g |
Shock duration |
30 ms |
Number of shocks per direction |
3 |
Test directions |
X-, Y- and Z-axis (pos. and neg.) |
Relative insulation material temperature index (Elec., UL 746 B) |
130 °C |
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) |
125 °C |
Static insulating material application in cold |
-60 °C |
Surface flammability NFPA 130 (ASTM E 162) |
passed |
Specific optical density of smoke NFPA 130 (ASTM E 662) |
passed |
Smoke gas toxicity NFPA 130 (SMP 800C) |
passed |
Calorimetric heat release NFPA 130 (ASTM E 1354) |
27,5 MJ/kg |
Fire protection for rail vehicles (DIN EN 45545-2) R22 |
HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R23 |
HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R24 |
HL 1 – HL 3 |
Fire protection for rail vehicles (DIN EN 45545-2) R26 |
HL 1 – HL 3 |
Dimensions
Width |
8.2 mm |
Length |
72.5 mm |
Height NS 35/7,5 |
56.5 mm |
Height NS 35/15 |
64 mm |
Height NS 32 |
61.5 mm |
Connection data
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
4 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
12 |
Conductor cross section flexible, with ferrule without plastic sleeve min. |
0.25 mm² |
Conductor cross section flexible, with ferrule without plastic sleeve max. |
4 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve min. |
0.25 mm² |
Conductor cross section flexible, with ferrule with plastic sleeve max. |
4 mm² |
Cross section with insertion bridge, solid max. |
4 mm² |
Cross section with insertion bridge, stranded max. |
4 mm² |
2 conductors with same cross section, solid min. |
0.2 mm² |
2 conductors with same cross section, solid max. |
1.5 mm² |
2 conductors with same cross section, stranded min. |
0.2 mm² |
2 conductors with same cross section, stranded max. |
1.5 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, minimum |
0.25 mm² |
Two conductors with the same cross section stranded, with ferrule and without plastic sleeve, maximum |
1.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, minimum |
0.5 mm² |
Two conductors with the same cross section, flexible, with TWIN ferrules, with plastic sleeve, maximum |
1.5 mm² |
Cross section with insertion bridge, solid max. |
4 mm² |
Cross section with insertion bridge, stranded max. |
4 mm² |
Connection method |
Screw connection |
Stripping length |
8 mm |
Internal cylindrical gage |
A4 |
Screw thread |
M3 |
Tightening torque, min |
0.6 Nm |
Tightening torque max |
0.8 Nm |
Ambient conditions
Operating temperature |
-60 °C … 105 °C (max. short-term operating temperature 125°C) |
Ambient temperature (storage/transport) |
-25 °C … 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) |
Permissible humidity (storage/transport) |
30 % … 70 % |
Ambient temperature (assembly) |
-5 °C … 70 °C |
Ambient temperature (actuation) |
-5 °C … 70 °C |
Standards and Regulations
Connection in acc. with standard |
CSA |
|
IEC 60947-7-3 |
Flammability rating according to UL 94 |
V0 |
Environmental Product Compliance
China RoHS |
Environmentally Friendly Use Period = 50 years |
|
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration” |