UC4-13346 Ultrasonic sensors – SICK Sensor

$ 382.14

SKU: SICK 6054708

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6054708
Distance Sensor Model: UC4-13346
OEM Spec Ref

Mechanics/electronics

Supply voltage Vs DC 15 V … 30 V 1)
Power consumption ≤ 0.75 W 2)
Initialization time < 300 ms
Design Rectangular
Housing material Plastic (ABS)

Ultrasonic transducer: polyurethane foam, glass epoxy resin

Connection type Male connector, M8, 3-pin
Indication 2 x LED
Weight 10 g
Sending axis Straight
Dimensions (W x H x D) 16 mm x 40.1 mm x 16.7 mm
Enclosure rating IP65 / IP67
Protection class III
  • 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
  • 2) Without load.

Performance

Operating range, limiting range 20 mm … 150 mm, 250 mm 1)
Target Natural objects
Resolution ≥ 0.1 mm
Repeatability ± 0.15 % 2)
Accuracy ± 1 % 3)
Temperature compensation
Response time 24 ms 4)
Output time 8 ms
Ultrasonic frequency (typical) 380 kHz
Detection area (typical) See diagrams
Additional function Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, invertable digital output, teach-in button(s) (can be deactivated), reset to factory default
5)
  • 1) Teach-in from 21 mm.
  • 2) In relation to the current measured value, minimum value ≥ resolution.
  • 3) Referring to current measurement value.
  • 4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
  • 5) Functions may vary depending on sensor type.

Interfaces

Analog output
Number 1
Type Current output
Current 4 mA … 20 mA, ≤ 500 Ω 1)
Resolution 12 bit
  • 1) For 4 mA … 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.

Ambient data

Ambient temperature, operation –25 °C … +70 °C 1)
Ambient temperature, storage –40 °C … +85 °C
  • 1) At operating temperatures of > 50 °C, the rear side of the UC4 must be installed with its surface flat against a bracket.