UC4-11341 Ultrasonic sensors – SICK Sensor
$ 402.60
SKU: SICK 6034667
SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.
Part Number: 6034667
Distance Sensor Model: UC4-11341
OEM Spec Ref
Mechanics/electronics
Supply voltage Vs | DC 15 V … 30 V 1) |
Power consumption | ≤ 0.75 W 2) |
Initialization time | < 300 ms |
Design | Rectangular |
Housing material | Plastic (ABS)
Ultrasonic transducer: polyurethane foam, glass epoxy resin |
Connection type | Male connector, M8, 3-pin |
Indication | 2 x LED |
Weight | 10 g |
Sending axis | Straight |
Dimensions (W x H x D) | 16 mm x 40.1 mm x 16.7 mm |
Enclosure rating | IP65 / IP67 |
Protection class | III |
- 1) Limit values, reverse-polarity protected, operation in short-circuit protected network: max. 8 A.
- 2) Without load.
Performance
Operating range, limiting range | 13 mm … 100 mm, 150 mm 1) |
Target | Natural objects |
Resolution | ≥ 0.1 mm |
Repeatability | ± 0.15 % 2) |
Accuracy | ± 1 % 3) |
Response time | 24 ms |
Switching frequency | 30 Hz |
Output time | 8 ms |
Ultrasonic frequency (typical) | 380 kHz |
Detection area (typical) | See diagrams |
Additional function | Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, invertable digital output, teach-in button(s) (can be deactivated), reset to factory default 4) |
- 1) Teach-in from 21 mm.
- 2) In relation to the current measured value, minimum value ≥ resolution.
- 3) Referring to current measurement value.
- 4) Functions may vary depending on sensor type.
Interfaces
|
|||||||||
Hysteresis | 2 mm |
- 1) PNP: HIGH = VS – (< 2 V) / LOW = 0 V.
Ambient data
Ambient temperature, operation | –25 °C … +70 °C 1) |
Ambient temperature, storage | –40 °C … +85 °C |
Temperature drift | 0.17 % / K 2) |
- 1) At operating temperatures of > 50 °C, the rear side of the UC4 must be installed with its surface flat against a bracket.