Contact Us:
sales@inosaki.com

UB2000-30GM-E5-V15 – Diffuse and Retroreflective Mode – PEPPERL+FUCHS Ultrasonic Sensors

$ 309.76

SKU UB2000-30GM-E5-V15 Category

PEPPERL+FUCHS Ultrasonic sensors are characterized by their reliability and outstanding versatility. Ultrasonic sensors can be used to solve even the most complex tasks involving object detection or level measurement with millimetre precision, because their measuring method works reliably under almost all conditions.

General specifications
Sensing range 80 … 2000 mm
Adjustment range 120 … 2000 mm
Dead band 0 … 80 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 180 kHz
Response delay approx. 150 ms
Indicators/operating means
LED green solid: Power-on
flashing: program function object detected
LED yellow solid: switching state switch output
flashing: program function
LED red normal operation: “fault”
program function: no object detected
Electrical specifications
Operating voltage 10 … 30 V DC , ripple 10 %SS
No-load supply current ≤ 50 mA
Input/Output
Synchronization bi-directional
0 level -UB…+1 V
1 level: +4 V…+UB
input impedance: > 12 KOhm
synchronization pulse: ≥ 100 µs, synchronization interpulse period: ≥ 2 ms
Synchronization frequency
Common mode operation max. 30 Hz
Multiplex operation ≤ 30 Hz / n , n = number of sensors , n ≤ 5
Input
Input type 1 program input,
operating range 1: -UB … +1 V, operating range 2: +4 V … +UB
input impedance: > 4.7 kΩ; program pulse: ≥ 1 s
Output
Output type 1 switch output PNP , Normally open/closed , programmable
Rated operating current 200 mA , short-circuit/overload protected
Voltage drop ≤ 2.5 V
Repeat accuracy ≤ 0.5 % of switching point
Switching frequency ≤ 3.3 Hz
Range hysteresis 1 % of the set operating distance
Temperature influence < 2 % of far switch point
Compliance with standards and directives
Standard conformity
Standards EN IEC 60947-5-2:2020
IEC 60947-5-2:2019
Approvals and certificates
UL approval cULus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated ≤36 V
Ambient conditions
Ambient temperature -25 … 70 °C (-13 … 158 °F)
Storage temperature -40 … 85 °C (-40 … 185 °F)
Mechanical specifications
Connection type Connector plug M12 x 1 , 5-pin
Housing diameter 30 mm
Degree of protection IP65
Material
Housing nickel plated brass; plastic components: PBT
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 140 g
Factory settings
Output Switch point A1: 220 mm
Switch point A2: 2100 mm
output function: Window mode
output behavior: NO contact

 

Associated Products: UB2000-30GM-E5-V15

Accessories

Mounting flange, 30 mm

Universal mounting bracket for cylindrical sensors with a diameter of 5 … 30 mm

Female cordset single-ended M12 straight A-coded, 5-pin, PVC cable grey

Female cordset single-ended M12 angled A-coded, 5-pin, PUR cable grey

Plastic mounting adapter, 30 mm

Programming unit

Ultrasonic -deflector, Universal mounting possibilities, 90° sound deflection for difficult installation circumstances, Focussing effect

Ultrasonic -deflector, Clamp mounting, 90° sound deflection for difficult installation circumstances, Universal Orientation

Plastic nuts with centering ring for the vibration-free mounting of cylindrical sensors, For insulated mounting

Additional information

Weight 0.140 kg

Related Products

BJX3M-PDT-C
SICK_sensor_Photoelectric_sensor_W12-2 Laser_WT12L-2B550T01
Siemens_SM 521 Digital Output Module
THK_Linear Bushing_LMF-L-1
SCHNEIDER_Standard Digital Output Kit STB-24 V DC-6 O
MOXA_Rackmount Switches_IKS-6726A-2GTXSFP-HV-HV-T
Select your currency