Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my
Product Description
TRIO POWER power supplies with standard functionality
The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.
Dimensions
Width |
42 mm |
Height |
130 mm |
Depth |
160 mm |
Installation dimensions |
Installation distance right/left |
0 mm / 0 mm |
Installation distance top/bottom |
50 mm / 50 mm |
Ambient Conditions
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C … 70 °C (> 60 °C Derating: 2,5 %/K) |
Ambient temperature (storage/transport) |
-40 °C … 85 °C |
Ambient temperature (start-up type tested) |
-25 °C |
Maximum altitude |
≤ 5000 m (> 2000 m, Derating: 10 %/1000 m) |
Climatic class |
3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz … 150 Hz, 4g, 90 min. |
Input Data
Network type |
Star network |
Nominal input voltage range |
100 V AC … 240 V AC |
Input voltage range |
100 V AC … 240 V AC -15 % … +10 % |
Switch-on voltage |
> 75 V AC |
Shut-down voltage |
< 70 V AC |
Electric strength, max. |
300 V AC 15 s |
Typical national grid voltage |
120 V AC |
230 V AC |
Voltage type of supply voltage |
AC/DC |
Inrush current |
≤ 25 A (typical) |
Inrush current integral (I2t) |
< 0.5 A2s |
Inrush current limitation |
typ. 25 A (after 1 ms) |
AC frequency range |
50 Hz … 60 Hz ±10 % |
Mains buffering time |
typ. 15 ms (120 V AC) |
typ. 20 ms (230 V AC) |
Current consumption |
3.1 A (100 V AC) |
2.4 A (120 V AC) |
1.3 A (230 V AC) |
1.4 A (240 V AC) |
Nominal power consumption |
285 VA |
Protective circuit |
Transient surge protection; Varistor |
Power factor (cos phi) |
0.93 |
Typical response time |
< 1 s |
Input fuse |
6.3 A (internal (device protection)) |
Recommended breaker for input protection |
6 A … 16 A (Characteristics B, C, D, K) |
Discharge current to PE |
< 3.5 mA |
POWER factor |
> 0.9 (120 V AC) |
> 0.9 (230 V AC) |
DC operation |
Nominal input voltage range |
110 V DC … 250 V DC |
Input voltage range |
110 V DC … 250 V DC -10 % … +10 % |
Switch-on voltage |
≥ 95 V DC |
Shut-down voltage |
< 70 V DC |
Voltage type of supply voltage |
AC/DC |
Mains buffering time |
> 15 ms (230 V AC) |
Current consumption |
2.5 A (110 V DC) |
1.1 A (250 V DC) |
Output Data
Efficiency |
> 91 % (for 230 V AC and nominal values) |
Output characteristic |
U/I with dynamic load reserve |
Nominal output voltage |
24 V DC ±1 % |
Setting range of the output voltage (USet) |
24 V DC … 28 V DC (constant capacity) |
Nominal output current (IN) |
10 A |
Dynamic Boost (IDyn.Boost) |
15 A (5 s) |
Derating |
> 60 °C … 70 °C (2.5%/K) |
Feedback voltage resistance |
≤ 35 V DC |
Protection against overvoltage at the output (OVP) |
≤ 30 V DC |
Control deviation |
< 1 % (change in load, static 10 % … 90 %) |
< 3 % (Dynamic load change 10 % … 90 %, 10 Hz) |
< 0.1 % (change in input voltage ±10 %) |
Residual ripple |
< 10 mVPP (with nominal values) |
Short-circuit-proof |
yes |
No-load proof |
yes |
Output power |
240 W |
360 W |
Maximum no-load power dissipation |
< 5.1 W (230 V) |
Power loss nominal load max. |
< 25 W |
Rise time |
≤ 12 ms (UOUT (10 % … 90 %)) |
Connection in parallel |
yes, for redundancy and increased capacity |
Connection in series |
yes |
Commercial Data
Item number |
2903149 |
Packing unit |
1 pc |
Minimum order quantity |
1 pc |
Sales Key |
C14 |
Product Key |
CMPO13 |
Catalog Page |
Page 256 (C-4-2019) |
GTIN |
4046356960854 |
Weight per Piece (including packing) |
1,145.9 g |
Weight per Piece (excluding packing) |
1,145.9 g |
Customs tariff number |
85044030 |
Country of origin |
CN |
Connection Data, Input
Connection method |
Push-in connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
4 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
12 |
Stripping length |
10 mm |
Connection Data, Output
Connection method |
Push-in connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
4 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
12 |
Stripping length |
8 mm |
Connection Data, Signal
Connection method |
Push-in connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
1.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
1.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
16 |
Stripping length |
8 mm |
Standards and Regulations
Rail applications |
EN 50121-4 |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
Standard – Electrical safety |
IEC 62368-1 (SELV) |
Standard – Safety extra-low voltage |
IEC 62368-1 (SELV) und EN 60204-1 (PELV) |
Standard – Safe isolation |
DIN VDE 0100-410 |
Standard – Safety of transformers |
EN 61558-2-16 (air clearances and creepage distances only) |
Conformance/Approvals
UL approvals |
UL Listed UL 508 |
UL/C-UL Recognized UL 60950-1 |
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Conformity/Approvals |
SIL in accordance with IEC 61508 |
0 |
EMC Data
Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
EMC requirements for noise emission |
EN 61000-6-3 |
EN 61000-6-4 |
EMC requirements for noise immunity |
EN 61000-6-1 |
EN 61000-6-2 |
Noise emission |
EN 55011 (EN 55022) |
Noise immunity |
EN 61000-6-2:2005 |
Electrostatic discharge |
Standards/regulations |
EN 61000-4-2 |
Electrostatic discharge |
Contact discharge |
6 kV (Test Level 4) |
Discharge in air |
8 kV (Test Level 4) |
Comments |
Criterion A |
Electromagnetic HF field |
Standards/regulations |
EN 61000-4-3 |
Electromagnetic HF field |
Frequency range |
80 MHz … 1 GHz |
Test field strength |
10 V/m (Test Level 3) |
Frequency range |
1 GHz … 2 GHz |
Test field strength |
10 V/m (Test Level 3) |
Frequency range |
2 GHz … 3 GHz |
Test field strength |
10 V/m (Test Level 3) |
Comments |
Criterion A |
Fast transients (burst) |
Standards/regulations |
EN 61000-4-4 |
Fast transients (burst) |
Input |
4 kV (Test Level 4 – asymmetrical) |
Output |
2 kV (Test Level 3 – asymmetrical) |
Signal |
1 kV (Test Level 2 – asymmetrical) |
Comments |
Criterion A |
Surge voltage load (surge) |
Standards/regulations |
EN 61000-4-5 |
Input |
3 kV (Test Level 3 – symmetrical) |
6 kV (Test Level 4 – asymmetrical) |
Output |
1 kV (Test Level 2 – symmetrical) |
2 kV (Test Level 1 – asymmetrical) |
Signal |
1 kV (Test Level 2 – asymmetrical) |
Comments |
Criterion B |
Conducted interference |
Standards/regulations |
EN 61000-4-6 |
Conducted interference |
Input/Output |
asymmetrical |
Frequency range |
0.15 MHz … 80 MHz |
Comments |
Criterion A |
Voltage |
10 V (Test Level 3) |
Emitted interference |
Standards/regulations |
EN 61000-6-3 |
Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criterion A |
Normal operating behavior within the specified limits. |
Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Environmental Product Compliance
REACh SVHC |
Lead 7439-92-1 |
|
China RoHS |
Environmentally Friendly Use Period = 25; |
For information on hazardous substances, refer to the manufacturer’s declaration available under “Downloads” |