TRIO-PS-2G/1AC/12DC/5/C2LPS – 2903157 – Phoenix Contact Power Supply

$ 182.60

SKU: Phoenix Contact 2903157

Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to  PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my

Product Description

TRIO POWER power supplies with standard functionality
The TRIO POWER power supply range with push-in connection has been perfected for use in machine building. All functions and the space-saving design of the single and three-phase modules are optimally tailored to the stringent requirements. Under challenging ambient conditions, the power supply units, which feature an extremely robust electrical and mechanical design, ensure the reliable supply of all loads.

Dimensions

Width 30 mm
Height 130 mm
Depth 115 mm
Installation distance right/left 0 mm / 0 mm
Installation distance top/bottom 50 mm / 50 mm

Ambient conditions

Degree of protection IP20
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Ambient temperature (operation) -25 °C … 70 °C (> 60 °C Derating: 2,5 %/K)
Ambient temperature (start-up type tested) -25 °C
Ambient temperature (storage/transport) -40 °C … 85 °C
Max. permissible relative humidity (operation) ≤ 95 % (at 25 °C, non-condensing)
Climatic class 3K3 (in acc. with EN 60721)
Degree of pollution 2
Installation height ≤ 5000 m (> 2000 m, Derating: 10 %/1000 m)

Input data

Nominal input voltage range 100 V AC … 240 V AC
110 V DC … 250 V DC
Input voltage range 100 V AC … 240 V AC -15 % … +10 %
99 V DC … 275 V DC
Dielectric strength maximum ≤ 300 V AC 15 s
AC frequency range 50 Hz … 60 Hz ±10 %
Discharge current to PE < 0.25 mA
Current consumption 1.1 A (100 V AC)
1 A (120 V AC)
0.6 A (230 V AC)
0.6 A (240 V AC)
Nominal power consumption 137.3 VA
Inrush current ≤ 25 A (typical)
Mains buffering time typ. 20 ms (120 V AC)
typ. 110 ms (230 V AC)
Input fuse 6.3 A Slow-blow
Recommended breaker for input protection 6 A … 16 A (Characteristics B, C, D, K)
Power factor (cos phi) 0.51
Type of protection Transient surge protection
Protective circuit/component Varistor

Output data

Nominal output voltage 12 V DC ±1 %
Setting range of the output voltage (USet) 12 V DC … 18 V DC (> 12 V DC, constant capacity restricted)
Nominal output current (IN) 5 A
Derating > 60 °C … 70 °C (2.5%/K)
Connection in parallel yes, for redundancy and increased capacity
Connection in series yes
Feedback voltage resistance < 25 V
Protection against overvoltage at the output (OVP) ≤ 22 V DC
Control deviation < 1 % (change in load, static 10 % … 90 %)
< 3 % (Dynamic load change 10 % … 90 %, 10 Hz)
< 0.1 % (change in input voltage ±10 %)
Residual ripple < 50 mVPP (with nominal values)
Output power 60 W
Typical response time < 1 s
Maximum power dissipation in no-load condition < 1 W (230 V)
Power loss nominal load max. < 10 W (230 V)

General

Article Number 2903157
Net weight 0.32 kg
Efficiency > 86 % (for 230 V AC and nominal values)
MTBF (IEC 61709, SN 29500) 25 °C
> 2900000 h (40 °C)
60 °C
Insulation voltage input/output 3 kV AC (type test)
1.5 kV AC (routine test)
Degree of protection IP20
Protection class II (in closed control cabinet)
Inflammability class in acc. with UL 94 (housing / terminal blocks) V0
Housing material PC
Mounting position horizontal DIN rail NS 35, EN 60715
Assembly instructions alignable: horizontally 0 mm (≤ 40 °C) 10 mm (≤ 70 °C), vertically 50 mm

Connection data, input

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 10 mm

Connection data, output

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 12
Stripping length 8 mm

Connection data for signaling

Connection method Push-in connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 1.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm

Standards

EMC requirements for noise immunity EN 61000-6-1
EN 61000-6-2
EMC requirements for noise emission EN 61000-6-3
EN 61000-6-4
Standard – Safety of transformers EN 61558-2-16 (air clearances and creepage distances only)
Standard – Electrical safety IEC 62368-1 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations EN 50178/VDE 0160 (PELV)
Standard – Safety extra-low voltage IEC 62368-1 (SELV) und EN 60204-1 (PELV)
Standard – Safe isolation DIN VDE 0100-410
Standard – Limitation of mains harmonic currents EN 61000-3-2
Rail applications EN 50121-4
Overvoltage category EN 60950-1 II

Conformance/approvals

UL approvals UL Listed UL 508
UL/C-UL Recognized UL 60950-1
NEC Class 2 as per UL 1310

EMC data

Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Low Voltage Directive Conformance with Low Voltage Directive 2014/35/EC
Electrostatic discharge EN 61000-4-2
Contact discharge 6 kV (Test Level 3)
Discharge in air 8 kV (Test Level 3)
Electromagnetic HF field EN 61000-4-3
Frequency range 80 MHz … 3 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 80 MHz … 3 GHz
Test field strength 10 V/m (Test Level 3)
Frequency range 80 MHz … 3 GHz
Test field strength 10 V/m (Test Level 3)
Comments Criterion A
Fast transients (burst) EN 61000-4-4
Input 4 kV (Test Level 3 – asymmetrical)
Output 2 kV (Test Level 3 – asymmetrical)
Signal 2 kV (Test Level 3 – asymmetrical)
Comments Criterion A
Surge voltage load (surge) EN 61000-4-5
Input 3 kV (Test Level 4 – symmetrical)
6 kV (Test Level 4 – asymmetrical)
Output 1 kV (Test Level 3 – symmetrical)
2 kV (Test Level 3 – asymmetrical)
Signal 1 kV (Test Level 2 – asymmetrical)
Comments Criterion A
Conducted interference EN 61000-4-6
Frequency range 0.15 MHz … 80 MHz
Voltage 10 V (Test Level 3)
Comments Criterion A
Voltage dips EN 61000-4-11
Voltage 230 V AC
Frequency 50 Hz
Criterion A Normal operating behavior within the specified limits.
Criterion B Temporary impairment to operational behavior that is corrected by the device itself.

Environmental Product Compliance

REACh SVHC Lead 7439-92-1
China RoHS Environmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer’s declaration”