Inosaki is one of the largest Phoenix Contact Distributors to provide terminal block, interface module, power supply and relay. And our best offer for terminal block types are Feed-through, Fuse Modular, Spring Cage, Double Level, and Multi-level, hence the series model references to PT Series, ST Series, TB Series, UT Series, UK Series. In additional for power supply are QUINT Power, STEP Power, Trio Power, and UNO Power. Please email us for catalog: sales@inosaki.my
Product Description
TRIO POWER power supplies with standard functionality
TRIO POWER is particularly suited to standard machine production, thanks to 1- and 3-phase versions up to 960 W. The wide-range input and the international approval package enable worldwide use.
The robust metal housing, the high electric strength, and the wide temperature range ensure a high level of power supply reliability.
Dimensions
Dimensional drawing |
|
Width |
40 mm |
Height |
130 mm |
Depth |
115 mm |
Ambient Conditions
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C … 70 °C (> 55° C derating : 2.5%/K) |
Ambient temperature (storage/transport) |
-40 °C … 85 °C |
Climatic class |
3K3 (in acc. with EN 60721) |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
Shock |
15g in all directions in acc. with IEC 60068-2-27 |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
15 Hz … 150 Hz, 2.3g, 90 min. |
Input Data
AC operation |
Nominal input voltage range |
100 V AC … 240 V AC |
Input voltage range |
85 V AC … 264 V AC (Derating < 90 V AC: 2,5 %/V) |
Derating |
< 90 V AC (2.5 %/V) |
Input voltage range AC |
85 V AC … 264 V AC (Derating < 90 V AC: 2,5 %/V) |
Electric strength, max. |
300 V AC |
Voltage type of supply voltage |
AC |
Inrush current |
< 15 A |
Inrush current integral (I2t) |
1.1 A2s |
AC frequency range |
45 Hz … 65 Hz |
Mains buffering time |
> 20 ms (120 V AC) |
> 110 ms (230 V AC) |
Current consumption |
1.65 A (120 V AC) |
0.9 A (230 V AC) |
Nominal power consumption |
189 VA |
Protective circuit |
Transient surge protection; Varistor |
Power factor (cos phi) |
0.72 |
Typical response time |
< 1 s |
Input fuse |
3.15 A (slow-blow, internal) |
Permissible backup fuse |
B6 B10 B16 |
Recommended breaker for input protection |
6 A … 16 A (Characteristics B, C, D, K) |
Discharge current to PE |
< 3.5 mA |
Output Data
Efficiency |
89 % (for 230 V AC and nominal values) |
Output characteristic |
U/I |
Nominal output voltage |
24 V DC ±1 % |
Setting range of the output voltage (USet) |
22.5 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) |
5 A (UOUT = 24 V DC) |
Derating |
55 °C … 70 °C (2.5%/K) |
Feedback voltage resistance |
35 V DC |
Protection against overvoltage at the output (OVP) |
< 35 V DC |
Max. capacitive load |
unlimited |
Active current limitation |
approx. 10 A (for short-circuit) |
Control deviation |
< 1 % (change in load, static 10 % … 90 %) |
< 2 % (change in load, dynamic 10 % … 90 %) |
< 0.1 % (change in input voltage ±10 %) |
Residual ripple |
< 20 mVPP |
Output power |
120 W |
Peak switching voltages nominal load |
< 30 mVPP |
Maximum no-load power dissipation |
1.1 W |
Power loss nominal load max. |
18 W |
Rise time |
< 2 ms (UOUT (10 % … 90 %)) |
Connection in parallel |
yes, for redundancy and increased capacity |
Connection in series |
yes |
Connection Data, Input
Connection method |
Screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
14 |
Stripping length |
9 mm |
Screw thread |
M2,5 |
Tightening torque, min |
0.4 Nm |
Tightening torque max |
0.5 Nm |
Connection Data, Output
Connection method |
Screw connection |
Conductor cross section, rigid min. |
0.2 mm² |
Conductor cross section, rigid max. |
2.5 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
2.5 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
14 |
Stripping length |
9 mm |
Screw thread |
M2,5 |
Tightening torque, min |
0.4 Nm |
Tightening torque max |
0.5 Nm |
Standards and Regulations
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
Standard – Electrical safety |
EN 60950-1/VDE 0805 (SELV) |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
Standard – Safety extra-low voltage |
EN 60950-1 (SELV) |
EN 60204 (PELV) |
Standard – Safe isolation |
DIN VDE 0100-410 |