| product brand name | SIRIUS | 
| product designation | timing relay | 
| design of the product | Clock generator, flashing, asymmetrical | 
| product type designation | 3RP25 | 
| General technical data | |
| product component | |
| ● relay output | Yes | 
| ● semi-conductor output | No | 
| product extension required remote control | No | 
| product extension optional remote control | No | 
| power loss [W] maximum | 2 W | 
| insulation voltage for overvoltage category III according to IEC 60664 with degree of pollution 3 rated value | 300 V | 
| test voltage for isolation test | 2.5 kV | 
| degree of pollution | 3 | 
| surge voltage resistance rated value | 4 000 V | 
| shock resistance according to IEC 60068-2-27 | 11g / 15 ms | 
| vibration resistance according to IEC 60068-2-6 | 10 … 55 Hz / 0.35 mm | 
| mechanical service life (operating cycles) typical | 10 000 000 | 
| electrical endurance (operating cycles) at AC-15 at 230 V typical | 100 000 | 
| adjustable time | 0.05 s … 100 h | 
| relative setting accuracy relating to full-scale value | 5 %; +/- | 
| thermal current | 5 A | 
| recovery time | 250 ms | 
| reference code according to IEC 81346-2 | K | 
| relative repeat accuracy | 1 %; +/- | 
| influence of the surrounding temperature | 1% in the whole temperature range to the set runtime | 
| power supply influence | 1% in the whole voltage range to the set runtime | 
| Substance Prohibitance (Date) | 09/12/2014 | 
| SVHC substance name | Lead monoxide (lead oxide) – 1317-36-8 | 
| Weight | 0.14 kg | 
| Control circuit/ Control | |
| type of voltage of the control supply voltage | AC/DC | 
| control supply voltage 1 at AC | |
| ● at 50 Hz | 12 … 240 V | 
| ● at 60 Hz | 12 … 240 V | 
| control supply voltage frequency 1 | 50 … 60 Hz | 
| control supply voltage 1 at DC | 12 … 240 V | 
| operating range factor control supply voltage rated value at DC | |
| ● initial value | 0.8 | 
| ● full-scale value | 1.1 | 
| operating range factor control supply voltage rated value at AC at 50 Hz | |
| ● initial value | 0.8 | 
| ● full-scale value | 1.1 | 
| operating range factor control supply voltage rated value at AC at 60 Hz | |
| ● initial value | 0.8 | 
| ● full-scale value | 1.1 | 
| inrush current peak | |
| ● at 24 V | 0.4 A | 
| ● at 240 V | 5 A | 
| duration of inrush current peak | |
| ● at 24 V | 0.4 ms | 
| ● at 240 V | 0.5 ms | 
| Switching Function | |
| switching function | |
| ● ON-delay | No | 
| ● ON-delay/instantaneous contact | No | 
| ● passing make contact | No | 
| ● passing make contact/instantaneous contact | No | 
| ● OFF delay | No | 
| switching function | |
| ● flashing symmetrically with interval start/instantaneous | No | 
| ● flashing symmetrically with interval start | No | 
| ● flashing symmetrically with pulse start/instantaneous | No | 
| ● flashing symmetrically with pulse start | No | 
| ● flashing asymmetrically with interval start | Yes | 
| ● flashing asymmetrically with pulse start | No | 
| switching function | |
| ● star-delta circuit with delay time | No | 
| ● star-delta circuit | No | 
| switching function with control signal | |
| ● additive ON-delay | No | 
| ● passing break contact | No | 
| ● passing break contact/instantaneous | No | 
| ● OFF delay | No | 
| ● OFF delay/instantaneous | No | 
| ● pulse delayed | No | 
| ● pulse delayed/instantaneous | No | 
| ● pulse-shaping | No | 
| ● pulse-shaping/instantaneous | No | 
| ● additive ON-delay/instantaneous | No | 
| ● ON-delay/OFF-delay/instantaneous | No | 
| ● passing make contact | No | 
| ● passing make contact/instantaneous contact | No | 
| switching function of interval relay with control signal | |
| ● retrotriggerable with deactivated control signal/instantaneous contact | No | 
| ● retrotriggerable with switched-on control signal | No | 
| ● retrotriggerable with switched-on control signal/instantaneous contact | No | 
| ● retriggerable with deactivated control signal | No | 
| Short-circuit protection | |
| design of the fuse link for short-circuit protection of the auxiliary switch required | fuse gL/gG: 4 A | 
| Auxiliary circuit | |
| material of switching contacts | AgSnO2 | 
| number of NC contacts | |
| ● delayed switching | 0 | 
| ● instantaneous contact | 0 | 
| number of NO contacts | |
| ● delayed switching | 0 | 
| ● instantaneous contact | 0 | 
| number of CO contacts | |
| ● delayed switching | 1 | 
| ● instantaneous contact | 0 | 
| operational current of auxiliary contacts at AC-15 | |
| ● at 24 V | 3 A | 
| ● at 250 V | 3 A | 
| operational current of auxiliary contacts at DC-13 | |
| ● at 24 V | 1 A | 
| ● at 125 V | 0.2 A | 
| ● at 250 V | 0.1 A | 
| operating frequency with 3RT2 contactor maximum | 5 000 1/h | 
| contact reliability of auxiliary contacts | one incorrect switching operation of 100 million switching operations (17 V, 5 mA) | 
| contact rating of auxiliary contacts according to UL | R300 / B300 | 
| switching capacity current with inductive load | 0.01 … 3 A | 
| Inputs/ Outputs | |
| product function | |
| ● at the relay outputs switchover delayed/without delay | No | 
| ● non-volatile | No | 
| Electromagnetic compatibility | |
| EMC emitted interference according to IEC 61812-1 | ambience A (industrial sector) | 
| EMC immunity according to IEC 61812-1 | corresponds to degree of severity 3 | 
| conducted interference | |
| ● due to burst according to IEC 61000-4-4 | 2 kV network connection / 1 kV control connection | 
| ● due to conductor-earth surge according to IEC 61000-4-5 | 2 kV | 
| ● due to conductor-conductor surge according to IEC 61000-4-5 | 1 kV | 
| field-based interference according to IEC 61000-4-3 | 10 V/m | 
| electrostatic discharge according to IEC 61000-4-2 | 4 kV contact discharge / 8 kV air discharge | 
| Safety related data | |
| category according to EN 954-1 | none | 
| Electrical Safety | |
| protection class IP on the front according to IEC 60529 | IP20 | 
| type of insulation | Basic insulation | 
| Connections/ Terminals | |
| product component removable terminal for auxiliary and control circuit | Yes | 
| type of electrical connection for auxiliary and control circuit | screw-type terminals | 
| type of connectable conductor cross-sections | |
| ● solid | 1x (0.5 … 4.0 mm²), 2x (0.5 … 2.5 mm²) | 
| ● finely stranded with core end processing | 1x (0.5 … 4 mm²), 2x (0.5 … 1.5 mm²) | 
| ● for AWG cables solid | 1x (20 … 12), 2x (20 … 14) | 
| ● for AWG cables stranded | 1x (20 … 12), 2x (20 … 14) | 
| connectable conductor cross-section | |
| ● solid | 0.5 … 4 mm² | 
| ● finely stranded with core end processing | 0.5 … 4 mm² | 
| AWG number as coded connectable conductor cross section | |
| ● solid | 20 … 12 | 
| ● stranded | 20 … 14 | 
| tightening torque | 0.6 … 0.8 N·m | 
| design of the thread of the connection screw | M3 | 
| Installation/ mounting/ dimensions | |
| mounting position | any | 
| fastening method | screw and snap-on mounting onto 35 mm DIN rail | 
| height | 100 mm | 
| width | 17.5 mm | 
| depth | 90 mm | 
| required spacing | |
| ● with side-by-side mounting | |
| — forwards | 0 mm | 
| — backwards | 0 mm | 
| — upwards | 0 mm | 
| — downwards | 0 mm | 
| — at the side | 0 mm | 
| ● for grounded parts | |
| — forwards | 0 mm | 
| — backwards | 0 mm | 
| — upwards | 0 mm | 
| — at the side | 0 mm | 
| — downwards | 0 mm | 
| ● for live parts | |
| — forwards | 0 mm | 
| — backwards | 0 mm | 
| — upwards | 0 mm | 
| — downwards | 0 mm | 
| — at the side | 0 mm | 
| Ambient conditions | |
| installation altitude at height above sea level maximum | 2 000 m | 
| ambient temperature | |
| ● during operation | -25 … +60 °C | 
| ● during storage | -40 … +85 °C | 
| ● during transport | -40 … +85 °C | 
| relative humidity during operation | 10 … 95 % |