$ 330.22 – $ 373.56
Main | |||
Part Number |
LTMR08MFM |
LTMR27MFM |
LTMR100MFM |
Range | TeSys | TeSys | TeSys |
Product name | TeSys T | TeSys T | TeSys T |
Device short name | LTMR | LTMR | LTMR |
Product or component type | Motor controller | Motor controller | Motor controller |
Device application | Equipment monitoring and control | Equipment monitoring and control | Equipment monitoring and control |
Measurement current | 0.4…8 A | 1.35…27 A | 5…100 A |
[Us] rated supply voltage | 100…240 V AC 50/60 Hz | 100…240 V AC 50/60 Hz | 100…240 V AC 50/60 Hz |
Current consumption | 8…62.8 mA | 8…62.8 mA | 8…62.8 mA |
supply voltage limits | 93.5…264 V AC | 93.5…264 V AC | 93.5…264 V AC |
Communication port protocol | Modbus | Modbus | Modbus |
bus type | Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs |
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs |
Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1…247, transmission rate 1.2…19.2 kbit/s, terminal block with 2 shielded twisted pairs |
Complementary | |||
[Ui] rated insulation voltage | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
[Uimp] rated impulse withstand voltage | 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 |
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 |
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 |
short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 | 100 kA conforming to EN/IEC 60947-4-1 | 100 kA conforming to EN/IEC 60947-4-1 |
associated fuse rating | 4 A gG for output 0.5 A gG for control circuit |
4 A gG for output 0.5 A gG for control circuit |
4 A gG for output 0.5 A gG for control circuit |
protection type | Reverse polarity protection Locked rotor Earth-leakage protection Thermal overload protection Phase failure Overload Thermal protection Power factor variation Load fluctuation Phase unbalance Overload (long time) |
Reverse polarity protection Overload (long time) Earth-leakage protection Phase unbalance Overload Load fluctuation Phase failure Power factor variation Thermal protection Locked rotor Thermal overload protection |
Load fluctuation Earth-leakage protection Overload (long time) Overload Locked rotor Thermal protection Thermal overload protection Power factor variation Reverse polarity protection Phase failure Phase unbalance |
Network and machine diagnosis type | Event recording Fault recording Waiting time after overload tripping Running hours counter/operating time Phase fault and earth fault trip counters Trip context information Starting current and time Motor control command recording Remaining operating time before overload tripping Trip history information |
Fault recording Starting current and time Remaining operating time before overload tripping Waiting time after overload tripping Motor control command recording Event recording Trip history information Running hours counter/operating time Phase fault and earth fault trip counters Trip context information |
Motor control command recording Starting current and time Trip history information Phase fault and earth fault trip counters Running hours counter/operating time Remaining operating time before overload tripping Fault recording Trip context information Event recording Waiting time after overload tripping |
Logic input number | 6 | 6 | 6 |
input current | 3.1 mA at 100 V 7.5 mA at 240 V |
3.1 mA at 100 V 7.5 mA at 240 V |
3.1 mA at 100 V 7.5 mA at 240 V |
current state 0 guaranteed | Logic input: 0…40 V and <= 15 mA for 25 ms | Logic input: 0…40 V and <= 15 mA for 25 ms | Logic input: 0…40 V and <= 15 mA for 25 ms |
current state 1 guaranteed | Logic input: 79…264 V and >= 2 mA for 25 ms | Logic input: 79…264 V and >= 2 mA for 25 ms | Logic input: 79…264 V and >= 2 mA for 25 ms |
maximum output switching frequency | 2 Hz | 2 Hz | 2 Hz |
load current | 5 A at 250 V AC for logic output 5 A at 30 V DC for logic output |
5 A at 250 V AC for logic output 5 A at 30 V DC for logic output |
5 A at 250 V AC for logic output 5 A at 30 V DC for logic output |
permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
Maximum operating rate | 1800 cyc/h | 1800 cyc/h | 1800 cyc/h |
contacts type and composition | 1 NO + 1 NC fault signal 3 NO |
1 NO + 1 NC fault signal 3 NO |
1 NO + 1 NC fault signal 3 NO |
Metering type | Average current Iavg Temperature Earth-fault current Imbalance current Phase current I1, I2, I3 RMS |
Temperature Phase current I1, I2, I3 RMS Average current Iavg Earth-fault current Imbalance current |
Temperature Earth-fault current Average current Iavg Imbalance current Phase current I1, I2, I3 RMS |
measurement accuracy | 5…15 % earth fault current internal measurement 1 % voltage (100…830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power |
5…15 % earth fault current internal measurement 1 % voltage (100…830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 1 % current 5 % active and reactive power |
5…15 % earth fault current internal measurement 1 % voltage (100…830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 5 % active and reactive power 0,02 current |
Overvoltage category | III | III | III |
Connection pitch | 5.08 mm | 5.08 mm | 5.08 mm |
connections – terminals | Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end |
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end |
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24…AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24…AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24…AWG 14) solid without cable end |
tightening torque | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm | Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm |
Pollution degree | 3 | 3 | 3 |
electromagnetic compatibility | Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 |
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 |
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 |
Width | 91 mm | 91 mm | 91 mm |
Height | 61 mm | 61 mm | 61 mm |
Depth | 122.5 mm | 122.5 mm | 122.5 mm |
Net weight | 0.53 kg | 0.53 kg | 0.53 kg |
Web services | Web server | Web server | Web server |
Compatibility code | LTMR | LTMR | LTMR |
Environment | |||
Standards | IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1 CSA C22.2 No 14 |
CSA C22.2 No 14 UL 508 EN 60947-4-1 IEC 60947-4-1 IACS E10 |
IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1 CSA C22.2 No 14 |
Product certifications | ABS KERI BV EAC CSA GL C-Tick ATEX UL RMRoS NOM CCC DNV RINA LROS (Lloyds register of shipping) |
RMRoS LROS (Lloyds register of shipping) RINA ABS CCC EAC UL GL NOM DNV KERI ATEX BV CSA C-Tick |
LROS (Lloyds register of shipping) UL ABS ATEX EAC CCC BV RINA DNV C-Tick RMRoS CSA GL NOM KERI |
protective treatment | 12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068 |
12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068 |
12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068 |
fire resistance | 650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 |
650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 |
650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 |
ambient air temperature for operation | -20…60 °C | -20…60 °C | -20…60 °C |
Ambient air temperature for storage | -40…80 °C | -40…80 °C | -40…80 °C |
operating altitude | <= 2000 m without derating | <= 2000 m without derating | <= 2000 m without derating |
mechanical robustness | Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
Vibrations mounted on symmetrical rail: 1 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5…300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |
IP degree of protection | IP20 | IP20 | IP20 |
Packing Units | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 7.200 cm | 7.2 cm | 7.2 cm |
Package 1 Width | 10.000 cm | 10.0 cm | 10.0 cm |
Package 1 Length | 13.600 cm | 13.6 cm | 13.6 cm |
Package 1 Weight | 524.0 g | 525.0 g | 536.0 g |
Unit Type of Package 2 | S02 | S02 | S02 |
Number of Units in Package 2 | 10 | 10 | 10 |
Package 2 Height | 15.000 cm | 15.0 cm | 15.0 cm |
Package 2 Width | 30.000 cm | 30.0 cm | 30.0 cm |
Package 2 Length | 40.000 cm | 40.0 cm | 40.0 cm |
Package 2 Weight | 5.594 kg | 5.604 kg | 5.586 kg |
Contractual warranty | |||
Warranty | 18 months | 18 months | 18 months |