TeSys Deca – LC1D – 4 Poles (4NO) Contactor, 115A – Schneider Contactors & Reversing Contactors
$ 401.72
SKU: LC1D115004M7
Specifications
Main | |
Part Number | LC1D115004M7 |
Product Series | TeSys |
Product Series | TeSys Deca |
product type | Contactor |
product short name | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive load, resistance furnace |
use category | AC-1 |
number of poles | 4P |
Rated working voltage [Ue] | Power circuit: <= 1000 V AC 25…400 Hz |
Power circuit: <= 460 V DC | |
Rated operating current [Ie] | 200 A 60 °C) at <= 440 V AC AC-1 for power circuits |
[Uc] control circuit voltage | 230V AC 50/60Hz |
Additional information | |
model | LC1D |
Loop contact type | 4 NO |
Contactor Compatibility Features | M14 |
protection cap | Bring |
Conventional thermal current [Ith] | 200 A at <60 °C for power circuits |
Rated making capacity [Irms] | 1260 A at 440 V for power circuits conforming to IEC 60947 |
Rated breaking capacity | 1100 A at 440 V for power circuits conforming to IEC 60947 |
Rated short-time withstand current [Icw] | 250 A at <40 °C – 10 min for power circuit |
550 A at <40 °C – 1 min for power circuit | |
950 A at <40 °C – 10 s for power circuit | |
1100 A at <40 °C – 1 s for power circuits | |
Fuses for use with relays | 250 A gG at <= 690 V with type 1 suitable power circuit |
200 A gG at <= 690 V with type 2 suitable power circuit | |
average impedance | 0.6 mΩ – Ith 200 A 50 Hz for power circuits |
power consumption per pole | 24W AC-1 |
Rated insulation voltage [Ui] | Power circuit: 600 V CSA certified |
Power circuit: 600 V UL certified | |
Power circuit: 1000 V conforming to IEC 60947-4-1 | |
Overvoltage category | III |
pollution level | 3 |
Rated impulse withstand voltage [Uimp] | 8 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 |
B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 | |
Mechanical life | 8 Mcycles |
Electrical life | 0.8 Mcycles <= 440 V at 200 A AC-1 Ue |
Control loop characteristics | AC at 50/60 Hz |
Surge Suppression Module | Built-in bidirectional peak current limiting diode |
Control voltage limit | 0.3…0.5 Uc -40…70 °C Release AC 50/60 Hz |
0.8…1.15 Uc -40…55 °C Run AC 50/60 Hz | |
1…1.15 Uc 55…70 °C Run AC 50 /60Hz | |
(~50Hz pickup) power consumption (VA) | 280…350 VA 60 Hz 0.8 20 °C) |
280…350 VA 50 Hz 0.8 20 °C) | |
(~50Hz hold) power consumption (VA) | 2…18 VA 60 Hz 0.3 20 °C) |
2…18 VA 50 Hz 0.3 20 °C) | |
heat dissipation | 3…8 W at 50/60 Hz |
action time | 6…20 ms open |
20…50 ms close | |
operating frequency | 2400 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Flexible wire with wire terminal |
Control circuit: Bolt fastening1 1…2.5 mm² Cable selection: Flexible wire with wire terminal | |
Control circuit: Bolt fastening1 1 …2.5 mm² Cable option: flexible without wire terminals | |
Control circuit: screw tight2 1…2.5 mm² Cable option: flexible without cable terminals | |
Control circuit: screw tight1 1…2.5 mm² Cable option : Solid without wire terminals | |
Control circuit: Bolt fastening2 1…2.5 mm² Cable selection: Hard wire without wire terminals | |
Power circuit: Terminal 1 10…120 mm² Cable selection: Flexible wire without wire Terminals | |
Power circuit: Terminal 2 10…50 mm² Cable option: Flexible cord without wire terminal | |
Power circuit: Terminal 1 10…120 mm² Cable option: Flexible cord with cable terminal | |
Power circuit: Terminal 2 10… 50 mm² Cable option: Flexible with wire terminals Power | |
circuit: Terminal 1 10…120 mm² Cable option: Solid without wire terminals | |
Power circuit: Terminal 2 10…50 mm² Cable option: Solid No With wire terminal | |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat |
Control circuit: 1.2 Nm via screwdriver No. 2 Phillips screw | |
power supply circuit: 12 Nm via terminal hex 4 mm | |
control circuit: 1.2 Nm via screwdriver With a screwdriver pozidriv No 2 | |
installation method | DIN rail installation |
base plate installation | |
environment | |
standard | CSA C22.2 No 14 |
EN 60947-4-1 | |
EN 60947-5-1 | |
IEC 60947-4-1 | |
IEC 60947-5-1 | |
UL 508 | |
certified product | CCC |
RINA | |
GOST | |
UL | |
CSA | |
LROS (Lloyds register of shipping) | |
BV | |
GL | |
DNV | |
UKCA | |
IP protection class | IP20 front panel complies with screwed |
Protective measures | TH conforms to IEC 60068-2-30 |
climate tolerance | Complies with IACS E10 for exposure to hot flashes |
Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes | |
ambient air temperature | -40…60 °C |
60…70 °C with derating | |
working altitude | 0…3000 m |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 |
flame retardant | V1 complies with UL 94 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) |
shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance | |
with contacts closed (15 gn (11ms)) | |
Shock performance Contact opening (6 gn (11ms)) | |
high | 158 mm |
width | 150 mm |
depth | 132 mm |
Product Weight | 2.86kg |
packaging unit | |
Unit Type of Package 1 | PCE |
Number of Units in Package 1 | 1 |
Package 1 Height | 19.500 cm |
Package 1 Width | 21.000 cm |
Package 1 Length | 21.000 cm |
Package 1 Weight | 2.971kg |
Unit Type of Package 2 | P06 |
Number of Units in Package 2 | 18 |
Package 2 Height | 75.000 cm |
Package 2 Width | 60.000 cm |
Package 2 Length | 80.000 cm |
Package 2 Weight | 66.478 kg |
contract warranty | |
Warranty | 18 months |
Weight | 2.86 kg |
---|---|
Dimensions | 13.2 × 15.0 × 15.8 cm |
Related products
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details
-
Select options This product has multiple variants. The options may be chosen on the product page Details