TeSys Deca – LC1D– 3 Poles (3NO) Contactor, 620A – Schneider Contactors & Reversing Contactors

$ 1,422.08

SKU: LC1D620Q7C

Specifications

Main
Part Number LC1D620Q7C
Product Series TeSys Deca
Product Series TeSys Deca
product type Contactor
product short name LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-1AC
-3
number of poles 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 1000 A 40 °C) at <= 440 V AC AC-1 for power circuits
620 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 380 V AC 50/60 Hz
Additional information
Motor power (kW) 200 kW at 220/240 V AC 50/60 Hz (AC-3)
335 kW at 380/400 V AC 50/60 Hz (AC-3)
375 kW at 415 V AC 50/60 Hz (AC-3)
400 kW at 440 V AC 50/60 Hz (AC-3)
400 kW at 500 V AC 50/60 Hz (AC-3)
450 kW at 660/690 V AC 50 /60 Hz (AC-3)
450 kW at 1000 V AC 50/60 Hz (AC-3)
model LC1D
Loop contact type 3 NO
protection cap None
Conventional thermal current [Ith] 1000 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 5050 A at <40 °C – 10 s for power circuit
4400 A at <40 °C – 30 s for power circuit
3400 A at <40 °C – 1 min for power circuit
2200 A at <40 °C – 3 minutes for power circuits
1600 A at <40 °C – 10 minutes for power circuits
Fuses for use with relays 800 A gG at <= 440 V for power circuits
630 A aM at <= 440 V for power circuits
1000 A gG at <= 440 V for power circuits
average impedance 0.12 mΩ – Ith 1000 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III
pollution level 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947
Mechanical life 5 Mcycles
Electrical life 0.33 Mcycles 1000 A AC-1 Ue <= 440 V
0.8 Mcycles 640 A AC-3 Ue <= 440 V
0.6 Mcycles 470 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50/60 Hz
Control voltage limit 0.85…1.1 Uc -5…55 °C operating 40…400 Hz
0.25…0.5 Uc -5…55 °C releasing 40…400 Hz
(~50Hz pickup) power consumption (VA) 1650 VA 50 Hz 0.9 20 °C)
1650 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 22 VA 50 Hz 0.9 20 °C)
22 VA 60 Hz 0.9 20 °C)
heat dissipation 22W
action time 40…80 ms closed
100…200 ms open
operating frequency 1200 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Control circuit: Bolt fastening Cable selection: Single solid wire without wire Wire terminal
Power circuit: Bus bar terminal Cable selection: Solid wire without wire terminal Bus bar cross section: 60 x 5 mm
Tightening torque
Control circuit: 1.2 Nm Power circuit via bolts : 58 Nm
Power circuit via busbar terminals: 58 Nm via cable connector
Auxiliary contact type Does not contain
installation method Rail installation
environment
standard IEC 60947-4-1
GB 14048.4
certified product CCC
CE
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4
gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock performance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
high 280mm
width 309 mm
depth 255 mm
Product Weight 20.1kg
packaging unit
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30.0cm
Package 1 Width 36.0cm
Package 1 Length 46.0cm
Package 1 Weight 18760.0 g
Unit Type of Package 2 P06
Number of Units in Package 2 4
Package 2 Height 75.0cm
Package 2 Width 60.0cm
Package 2 Length 80.0cm
Package 2 Weight 85.04 kg
contract warranty
Warranty 18 months

 

Weight 20.1 kg
Dimensions 25.5 × 30.9 × 28.0 cm