Contact Us:
sales@inosaki.com

TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 410A – Schneider Contactors & Reversing Contactors

$ 543.84$ 557.92

Specifications

Main
Part Number LC1D410F7C LC1D410M5C LC1D410M7C LC1D410Q7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-3AC
-1
AC-3AC
-1
AC-3AC
-1
AC-1AC
-3
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 500 A 40 °C) at <= 440 V AC AC-1 for power circuits
410 A 40 °C) at <= 440 V AC AC-3 for power circuits
500 A 40 °C) at <= 440 V AC AC-1 for power circuits
410 A 40 °C) at <= 440 V AC AC-3 for power circuits
500 A 40 °C) at <= 440 V AC AC-1 for power circuits
410 A 40 °C) at <= 440 V AC AC-3 for power circuits
500 A 40 °C) at <= 440 V AC AC-1 for power circuits
410 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 110V AC 50/60Hz 230V AC 50Hz 230V AC 50/60Hz 380 V AC 50/60 Hz
Additional information
Motor power (kW) 110 kW at 220/240 V AC 50/60 Hz (AC-3)
220 kW at 380/400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660/690 V AC 50 /60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
110 kW at 220/240 V AC 50/60 Hz (AC-3)
220 kW at 380/400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660/690 V AC 50 /60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
110 kW at 220/240 V AC 50/60 Hz (AC-3)
220 kW at 380/400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660/690 V AC 50 /60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
110 kW at 220/240 V AC 50/60 Hz (AC-3)
220 kW at 380/400 V AC 50/60 Hz (AC-3)
220 kW at 415 V AC 50/60 Hz (AC-3)
250 kW at 440 V AC 50/60 Hz (AC-3)
250 kW at 500 V AC 50/60 Hz (AC-3)
280 kW at 660/690 V AC 50 /60 Hz (AC-3)
185 kW at 1000 V AC 50/60 Hz (AC-3)
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
protection cap None None None None
Conventional thermal current [Ith] 500 A at <40 °C for power circuits 500 A at <40 °C for power circuits 500 A at <40 °C for power circuits 500 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 3600 A at <40 °C – 10 s for power circuit
2400 A at <40 °C – 30 s for power circuit
1700 A at <40 °C – 1 min for power circuit
1200 A at <40 °C – 3 minutes for power circuits
1000 A at <40 °C – 10 minutes for power circuits
3600 A at <40 °C – 10 s for power circuit
2400 A at <40 °C – 30 s for power circuit
1700 A at <40 °C – 1 min for power circuit
1200 A at <40 °C – 3 minutes for power circuits
1000 A at <40 °C – 10 minutes for power circuits
3600 A at <40 °C – 10 s for power circuit
2400 A at <40 °C – 30 s for power circuit
1700 A at <40 °C – 1 min for power circuit
1200 A at <40 °C – 3 minutes for power circuits
1000 A at <40 °C – 10 minutes for power circuits
3600 A at <40 °C – 10 s for power circuit
2400 A at <40 °C – 30 s for power circuit
1700 A at <40 °C – 1 min for power circuit
1200 A at <40 °C – 3 minutes for power circuits
1000 A at <40 °C – 10 minutes for power circuits
Fuses for use with relays 400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
630 A gG at <= 440 V for power circuits
400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
630 A gG at <= 440 V for power circuits
400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
630 A gG at <= 440 V for power circuits
400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
630 A gG at <= 440 V for power circuits
average impedance 0.26 mΩ – Ith 500 A 50 Hz for power circuits 0.26 mΩ – Ith 500 A 50 Hz for power circuits 0.26 mΩ – Ith 500 A 50 Hz for power circuits 0.26 mΩ – Ith 500 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947
Mechanical life 8 Mcycles 8 Mcycles 8 Mcycles 8 Mcycles
Electrical life 0.5 Mcycles 500 A AC-1 Ue <= 440 V
0.9 Mcycles 370 A AC-3 Ue <= 440 V
0.7 Mcycles 305 A AC-3 Ue 660/690 V
0.5 Mcycles 500 A AC-1 Ue <= 440 V
0.9 Mcycles 370 A AC-3 Ue <= 440 V
0.7 Mcycles 305 A AC-3 Ue 660/690 V
0.5 Mcycles 500 A AC-1 Ue <= 440 V
0.9 Mcycles 370 A AC-3 Ue <= 440 V
0.7 Mcycles 305 A AC-3 Ue 660/690 V
0.5 Mcycles 500 A AC-1 Ue <= 440 V
0.9 Mcycles 370 A AC-3 Ue <= 440 V
0.7 Mcycles 305 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50/60 Hz AC at 50 Hz AC at 50/60 Hz AC at 50/60 Hz
Control voltage limit 0.3…0.5 Uc -5…55 °C release 40…400 Hz
0.85…1.1 Uc -5…55 °C run 40…400 Hz
0.3…0.5 Uc -5…55 °C release 40…400 Hz
0.85…1.1 Uc -5…55 °C run 40…400 Hz
0.3…0.5 Uc -5…55 °C release 40…400 Hz
0.85…1.1 Uc -5…55 °C run 40…400 Hz
0.3…0.5 Uc -5…55 °C release 40…400 Hz
0.85…1.1 Uc -5…55 °C run 40…400 Hz
(~50Hz pickup) power consumption (VA) 1075 VA 50 Hz 0.9 20 °C)
1075 VA 60 Hz 0.9 20 °C)
1075VA 50Hz (0.920°C) 1075 VA 50 Hz 0.9 20 °C)
1075 VA 60 Hz 0.9 20 °C)
1075 VA 50 Hz 0.9 20 °C)
1075 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 15 VA 50 Hz 0.9 20 °C)
15 VA 60 Hz 0.9 20 °C)
15VA 50Hz (0.920°C) 15 VA 50 Hz 0.9 20 °C)
15 VA 60 Hz 0.9 20 °C)
15 VA 50 Hz 0.9 20 °C)
15 VA 60 Hz 0.9 20 °C)
heat dissipation 14W 14W 14W 14W
action time 100…170 ms open
40…75 ms close
100…170 ms open
40…75 ms close
100…170 ms open
40…75 ms close
100…170 ms open
40…75 ms close
operating frequency 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Solid wire without wire terminals Power
circuit: Bus bar terminals
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Tightening torque Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Auxiliary contact type Does not contain Does not contain Does not contain Does not contain
installation method Rail installation Rail installation Rail installation Rail installation
environment
standard IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
CCC
CE
CCC
CE
CCC
CE
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None 3000 m None
Shock and vibration resistance Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5 gn) …300 Hz)) conforming to IEC 60068-2-6
shock resistance contact opening (1.5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5 gn) …300 Hz)) conforming to IEC 60068-2-6
shock resistance contact opening (1.5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5 gn) …300 Hz)) conforming to IEC 60068-2-6
shock resistance contact opening (1.5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance 11 ms with contacts open (6 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5 gn) …300 Hz)) conforming to IEC 60068-2-6
shock resistance contact opening (1.5 gn (5…300 Hz)) conforming to IEC 60068-2-6
high 206 mm 206 mm 206 mm 206 mm
width 213 mm 213mm 213 mm 213 mm
depth 219 mm 219 mm 219 mm 219 mm
Product Weight 10.05kg 10.05kg 10.05kg 10.05kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 26.0cm 26.0cm 26.0cm 25.0cm
Package 1 Width 25.0cm 25.0cm 24.9 cm 25.0cm
Package 1 Length 30.0cm 30.0cm 29.3 cm 30.0cm
Package 1 Weight 9444.0 g 9444.0 g 9.182kg 9.11kg
Unit Type of Package 2 P06 P06 PAL PAL
Number of Units in Package 2 10 10 10 10
Package 2 Height 67.0cm 67.0cm 46.0cm 46.0cm
Package 2 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 2 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 2 Weight 104.44kg 104.44kg 95.84kg 94.34kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Additional information

Weight N/A
Dimensions N/A

Related Products

Omron_Switch Mode Power Supply_S8FS-C03505J
PEPPERLFUCHS_Sensor-Actuator Cables_V1-W-5M-PUR
CY-111B
Festo_Actuator-specific accessories_DADB-S1-40-S176-250
QS18VN6DBQ8
Flat Washer M(8)
$ 8.76 - $ 14.08
Select your currency