$ 32.34 – $ 120.78
Main | ||||
Part Number | LC1D40AB7C | LC1D40ACC7C | LC1D40AE7C | LC1D40AF7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 24 V AC 50/60 Hz | 36 V AC 50/60 Hz | 48 V AC 50/60 Hz | 110V AC 50/60Hz |
Additional information | ||||
Motor power (kW) | 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
average impedance | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 6 Mcycles | 6 Mcycles | 6 Mcycles | 6 Mcycles |
Electrical life | 1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
heat dissipation | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz |
action time | 4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Tightening torque | Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
environment | ||||
standard | GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
high | 122mm | 122mm | 122mm | 122mm |
width | 55mm | 55mm | 55mm | 55mm |
depth | 120 mm | 120 mm | 120 mm | 120 mm |
Product Weight | 0.85 kg | 0.85 kg | 0.85 kg | 0.85 kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 6.366 cm | 6.271 cm | 6.245 cm | 6.046 cm |
Package 1 Width | 13.405 cm | 13.848 cm | 13.747 cm | 13.663 cm |
Package 1 Length | 15.071 cm | 15.315 cm | 15.707 cm | 15.316 cm |
Package 1 Weight | 940.0g | 931.0g | 950.0g | 950.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 10 | 10 | 10 | 10 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 9.86kg | 9.841 kg | 9.91kg | 9.881kg |
Unit Type of Package 3 | PAL | PAL | PAL | PAL |
Number of Units in Package 3 | 160 | 160 | 160 | 160 |
Package 3 Height | 75.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 160.864 kg | 160.864 kg | 160.864 kg | 160.864 kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number | LC1D40AM7 | LC1D40AM7C | LC1D40AQ7C | LC1D40B7C |
Product Series | TeSys TeSys Deca |
TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D | LC1D |
Application field of contactor | Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 60 A 60 °C) at <= 440 V AC AC-1 for power circuit 40 A 60 °C) at <= 440 V AC AC-3 for power circuit 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 230V AC 50/60Hz | 230V AC 50/60Hz | 380 V AC 50/60 Hz | 24 V AC 50/60 Hz |
Additional information | ||||
Motor power (kW) | 18.5 kW at 380…400 V AC 50/60 Hz (AC-3) 11 kW at 220…230 V AC 50/60 Hz (AC-3) 22 kW at 415.. .440 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 30 kW at 660…690 V AC 50/60 Hz (AC-3 ) 9 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380…400 V AC 50/60 Hz (AC-3e) 11 kW at 220…230 V AC 50/60 Hz (AC-3e) 22 kW at 415…440 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 30 kW at 660…690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
Motor Power | 5 hp at 230/240 V AC 50/60 Hz for 1-phase motors 10 hp at 230/240 V AC 50/60 Hz for 3-phase motors 30 hp at 575/600 V AC 50/60 Hz For 3-phase motors 10 hp at 200/208 V AC 50/60 Hz For 3-phase motors 3 hp at 115 V AC 50/60 Hz For 1-phase motors 30 hp at 460/480 V AC 50/ 60 Hz for 3-phase motors |
|||
model | LC1D | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO | 3 NO |
Contactor Compatibility Features | M2 | |||
protection cap | Bring | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
Rated making capacity [Irms] | 140 A AC for signal circuits according to IEC 60947-5-1 250 A DC for signal circuits according to IEC 60947-5-1 800 A at 440 V for power circuits according to IEC 60947 |
|||
Rated breaking capacity | 800 A at 440 V for power circuits conforming to IEC 60947 | |||
Rated short-time withstand current [Icw] | 320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
320 A at <40 °C – 10 s for power circuit 720 A at <40 °C – 1 s for power circuit 72 A at <40 °C – 10 min for power circuit 165 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
240 A at <40 °C – 10 s for power circuit 380 A at <40 °C – 1 s for power circuit 50 A at <40 °C – 10 min for power circuit 120 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
average impedance | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits |
power consumption per pole | 2.4W AC-3 5.4W AC-1 2.4W AC-3e |
|||
Rated insulation voltage [Ui] | Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Signal circuit: 690 V conforming to IEC 60947-1 Signaling circuit: 600 V CSA certified Signaling circuit: 600 V UL certified Power circuit: 690 V conforming to IEC 60947-4-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Power circuit: 690 V conforming to IEC 60947-4-1 Signal circuit: 690 V conforming to IEC 60947-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III | III |
pollution level | 3 | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 6 Mcycles | 6 Mcycles | 6 Mcycles | 6 Mcycles |
Electrical life | 1.4 Mcycles 60 A AC-1 <= 440 V at Ue 1.5 Mcycles 40 A AC-3 Ue <= 440 V 1.5 Mcycles 40 A AC-3e <= 440 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz standard | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…70 °C Release AC 50/60 Hz 0.8…1.1 Uc -40…60 °C Run AC 50 Hz 0.85…1.1 Uc -40…60 °C Run AC 60 Hz 1…1.1 Uc 60…70 °C Operation AC 50/60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
140 VA 60 Hz 0.75 20 °C) 160 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
13 VA 60 Hz 0.3 20 °C) 15 VA 50 Hz 0.3 20 °C) |
26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
heat dissipation | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 4…5 W at 50/60 Hz | 6…10 W at 50/60 Hz |
action time | 4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
4…19 ms open 12…26 ms close |
20…26 ms close 8…12 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: screw-on2 1…2.5 mm² Cable option: flexible cord with wire terminal Control circuit: screw-on1 1…4 mm² Cable option: flexible cable without cable terminal Control circuit: screw-on2 1…4 mm² cable option: flexible without cable terminals Control circuit: screw-on1 1…4 mm² cable option: flexible cable with cable terminal control circuit: screw-on1 1…4 mm² cable option : Hard wire without wire terminal Control circuit: Bolt fastening2 1…4 mm² Cable option: Hard wire without wire terminal Power circuit: EverLink BTR terminal1 1…35 mm² Cable option: Flexible wire without Wire terminal power circuit: EverLink BTR terminal 2 1…25 mm² Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 1 1…35 mm² Cable selection: flexible cord with wire terminal power circuit : EverLink BTR terminal block 2 1…25 mm² Cable option: flexible wire with wire terminal Power circuit: EverLink BTR terminal block 1 1…35 mm² Cable option: rigid without wire terminal Power circuit: EverLink BTR terminal block 2 1…25 mm² Cable option: solid without cable terminals |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Power circuit: EverLink BTR terminal 1 1…35 mm² lug outer diameter Ø: 16.5 mm Cable selection: flexible cord without wire terminal Power circuit: EverLink BTR terminal 2 1…25 mm² lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord without wire terminals Power circuit: EverLink BTR terminal 2 1…35 mm² Lug outer diameter Ø: 16.5 mm Cable selection: Flexible cord with wire terminals Power circuit: EverLink BTR terminal 1 …25 mm² O.D. of lug: 16.5 mm Cable option : flexible wire with wire terminal Terminal Power circuit: EverLink BTR terminal block 1…25 mm² Lug outer diameter Ø: 16.5 mm Cable selection: hard wire without wire terminal Control circuit: screw fastening 1…4 mm² Cable selection: flexible wire without wire Wire terminal Control circuit: Bolt tight 1…2.5 mm² Cable option: Flexible wire with wire terminal Control circuit: Screw tight 1…4 mm² Cable option: Solid without wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal |
Tightening torque | Control circuit: 1.7 Nm via screwdriver Ø 6 flat control circuit: 1.7 Nm via screwdriver No. 2 Phillips screw power circuit: 8 Nm via EverLink BTR terminal block cable 25…35 mm² hexagonal 4 mm power circuit : 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagonal 4 mm control circuit: 1.7 Nm via screwdriver pozidriv No 2 power circuit: 2.5 Nm via screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm Via bolt fastening with screwdriver Ø 6 Flat control circuit: 1.7 Nm Via bolt fastening with screwdriver No. 2 Phillips screw Power circuit: 8 Nm Via EverLink BTR terminal block Cable 35 mm² Hexagonal 4 mm Power circuit: 6 Nm by bolting hexagon 10 mm screw: M6 power circuit: 5 Nm via EverLink BTR terminal block cable 1…25 mm² hexagon 4 mm control circuit: 1.7 Nm by bolting with screwdriver pozidriv No 2 |
Control circuit: 1.7 Nm via screwdriver No. 2 Phillips screw power supply circuit: 2.5 Nm via screwdriver Ø 6…8 mm slotted control circuit: 2.5 Nm via screwdriver Ø 6 flat power supply Circuit: 1.7 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5 Power circuit: 2.5 Nm Via cable connector with screwdriver No. 2 Phillips screw: M5 2.5 Nm |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching voltage | 17 V for signal return | |||
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
DIN rail installation base plate installation |
DIN rail installation base plate installation |
Chassis mounting rail installation |
environment | ||||
standard | CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 IEC 60335-1 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
IEC 60947-4-1 GB 14048.4 |
certified product | CCC GOST UL CSA |
CCC CE UKCA |
CCC CE UKCA |
CCC UKCA CE |
IP protection class | IP20 front panel complies with screwed | IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 IP2x front panel for coil circuits conforming to IEC 60529 |
IP2x front panel for main circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
climate tolerance | Complies with IACS E10 for exposure to hot flashes Complies with IEC 60947-1 Annex Q category D for exposure to hot flashes |
|||
ambient air temperature | -40…60 °C 60…70 °C with derating |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 0…3000m | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-1 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
flame retardant | V1 complies with UL 94 | |||
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) shock resistance with contacts closed (4 gn (5…300 Hz)) shock resistance with contacts closed (15 gn (11ms)) Shock performance Contact opening (10 gn (11ms)) |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27 |
high | 122mm | 122mm | 122mm | 127mm |
width | 55mm | 55mm | 55mm | 75 mm |
depth | 120 mm | 120 mm | 120 mm | 119mm |
Product Weight | 0.85 kg | 0.85 kg | 0.85 kg | 1.4kg |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 6.2 cm | 6.27cm | 6.22cm | 14.2 cm |
Package 1 Width | 13.5cm | 13.49 cm | 13.49 cm | 11.1 cm |
Package 1 Length | 15.2 cm | 15.07cm | 15.05cm | 14.5cm |
Package 1 Weight | 915.0g | 973.89g | 982.09g | 1328.54g |
Unit Type of Package 2 | S02 | S02 | S02 | S03 |
Number of Units in Package 2 | 10 | 10 | 10 | 12 |
Package 2 Height | 15.0cm | 15.0cm | 15.0cm | 30.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 9.776 kg | 9.871kg | 9.97kg | 16.5 kg |
Unit Type of Package 3 | P06 | PAL | PAL | P06 |
Number of Units in Package 3 | 160 | 160 | 160 | 96 |
Package 3 Height | 77.0cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 80.0cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 60.0cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 164.9 kg | 160.864 kg | 160.864 kg | 142.0 kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | |||
Part Number | LC1D40F7C | LC1D40Q7C | LC1D40M7C |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
Product Series | TeSys Deca | TeSys Deca | TeSys Deca |
product type | Contactor | Contactor | Contactor |
product short name | LC1D | LC1D | LC1D |
Application field of contactor | Applied to AC loads with power factor greater than or equal to 0.95 Applied to non-inductive or slightly inductive loads, resistance furnaces |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
Applied to non-inductive or micro-inductive loads, and resistance furnaces to AC loads with a power factor greater than or equal to 0.95 |
use category | AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
AC-4 AC-1 AC-3 AC-3e |
number of poles | 3P | 3P | 3P |
Rated working voltage [Ue] | Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Power circuit: <= 690 V AC 25…400 Hz Power circuit: <= 300 V DC |
Rated operating current [Ie] | 40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
40 A 60 °C) at <= 440 V AC AC-3 for power circuits 60 A 60 °C) at <= 440 V AC AC-1 for power circuits 40 A 60 °C) at< = 440 V AC AC-3e for power circuit |
[Uc] control circuit voltage | 110V AC 50/60Hz | 380 V AC 50/60 Hz | 230V AC 50/60Hz |
Additional information | |||
Motor power (kW) | 18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 18.5 kW at 380/ 400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC-3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at… at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC -3e) |
18.5 kW at 380/400 V AC 50/60 Hz (AC-3) 22 kW at 500 V AC 50/60 Hz (AC-3) 11 kW at 220/240 V AC 50/60 Hz (AC-3) 22 kW at 415/440 V AC 50/60 Hz (AC-3) 30 kW at 660/690 V AC 50/60 Hz (AC-3) 9 kW at 400 V AC 50/60 Hz (AC-4) 18.5 kW at 380/400 V AC 50/60 Hz (AC-3e) 22 kW at 500 V AC 50/60 Hz (AC-3e) 11 kW at… at 220/240 V AC 50/60 Hz (AC-3e) 22 kW at 415/440 V AC 50/60 Hz (AC-3e) 30 kW at 660/690 V AC 50/60 Hz (AC -3e) |
model | LC1D | LC1D | LC1D |
Loop contact type | 3 NO | 3 NO | 3 NO |
protection cap | None | None | None |
Conventional thermal current [Ith] | 10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
10 A at <60 °C for signal circuits 60 A at <60 °C for power circuits |
Rated short-time withstand current [Icw] | 240 A at <40 °C – 10 s for power circuit 380 A at <40 °C – 1 s for power circuit 50 A at <40 °C – 10 min for power circuit 120 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
240 A at <40 °C – 10 s for power circuit 380 A at <40 °C – 1 s for power circuit 50 A at <40 °C – 10 min for power circuit 120 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
240 A at <40 °C – 10 s for power circuit 380 A at <40 °C – 1 s for power circuit 50 A at <40 °C – 10 min for power circuit 120 A at <40 °C – 1 minute for power circuit 100 A – 1 s for signal circuit 120 A – 500 ms for signal circuit 140 A – 100 ms for signal circuit |
Fuses for use with relays | 10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
10 A gG for signal circuits according to IEC 60947-5-1 80 A gG at <= 690 V for power circuits type 1 80 A gG for power circuits for type 2 at <= 690 V |
average impedance | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits | 1.5 mΩ – Ith 60 A 50 Hz for power circuits |
Rated insulation voltage [Ui] | Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Signal circuit: 690 V conforming to IEC 60947-1 Power circuit: 1000 V conforming to IEC 60947-4-1 |
Overvoltage category | III | III | III |
pollution level | 3 | 3 | 3 |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Safety and reliability level | B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
B10d = Contactor for 1369863 nominal loads according to EN/ISO 13849-1 B10d = Contactor for 20000000 mechanical loads according to EN/ISO 13849-1 |
Mechanical life | 6 Mcycles | 6 Mcycles | 6 Mcycles |
Electrical life | 1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
1.6 Mcycles 40 A AC-3 Ue <= 440 V 1.6 Mcycles 33 A AC-3 Ue 660/690 V 1.4 Mcycles 60 A AC-1 Ue <= 440 V 1.6 Mcycles 40 A AC-3e Ue <= 440 V at 1.6 Mcycles 33 A AC-3e at 660/690 V at Ue |
Control loop characteristics | AC at 50/60 Hz | AC at 50/60 Hz | AC at 50/60 Hz |
Surge Suppression Module | No built-in surge suppression module | No built-in surge suppression module | No built-in surge suppression module |
Control voltage limit | 0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
0.3…0.6 Uc -40…60 °C release 50/60 Hz 0.8…1.1 Uc -40…60 °C run 50 Hz 0.85…1.1 Uc -40…60 °C run 60 Hz |
(~50Hz pickup) power consumption (VA) | 245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
245 VA 60 Hz 0.75 20 °C) 245 VA 50 Hz 0.75 20 °C) |
(~50Hz hold) power consumption (VA) | 26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
26 VA 60 Hz 0.3 20 °C) 26 VA 50 Hz 0.3 20 °C) |
heat dissipation | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz | 6…10 W at 50/60 Hz |
action time | 20…26 ms close 8…12 ms break |
20…26 ms close 8…12 ms break |
20…26 ms close 8…12 ms break |
operating frequency | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C | 3600 cycles/h at <60 °C |
Wiring capacity | Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal |
Control circuit: Bolt fastening1 1…4 mm² Cable selection: Flexible cord without wire terminals Control circuit: Bolt fastening2 1…4 mm² Cable selection: Flexible cord without wire terminal Control circuit: Bolt fastening 2 1…2.5 mm² cable option: flexible cable with wire terminals control circuit: screw-on1 1…4 mm² cable option: rigid without cable terminal control circuit: screw-on2 1…4 mm² cable option Type: Solid without wire terminals Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable selection: Flexible wire without wire terminals Power circuit: Bolt fastening2 2.5…16 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord without wire terminal Power circuit: screw fastening1 2.5…25 mm² Lug outer diameter Ø: 13 mm Cable option: flexible cord with wire terminal Power circuit : Bolt fastening2 2.5…10 mm² Lug O.D. Ø: 13 mm Cable option: Flexible cord with wire terminal Power circuit: Bolt fastening1 2.5…25 mm² Lug O.D. Ø: 13 mm Cable option: Solid wire without wire terminal Power circuit: screw fastened2 2.5…16 mm² lug outer diameter Ø: 13 mm Cable selection: rigid wire without wire terminal Control circuit: screw fastened1 1…2.5 mm² Cable optional Type: flexible wire with wire terminal |
Tightening torque | Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5 Power circuit: 5 Nm Via cable connector with screwdriver No 2 Phillips screw: M5 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5 Power circuit: 5 Nm Via cable connector with screwdriver No 2 Phillips screw: M5 |
Control circuit: 1.2 Nm via screwdriver Ø 6 flat control circuit: 1.2 Nm via screwdriver No 2 Phillips screw Power circuit: 5 Nm via screwdriver Ø 6…8 mm Slotted power supply Circuit: 5 Nm Via cable connector with screwdriver Ø 8 slotted screw: M5 Power circuit: 5 Nm Via cable connector with screwdriver No 2 Phillips screw: M5 |
Auxiliary contact type | 1 NO + 1 NC | 1 NO + 1 NC | 1 NO + 1 NC |
Auxiliary contact type | Type Mechanical connection 1 NO + 1 NC conforming to IEC 60947-5-1 Type mirrored with main contact status 1 NC conforming to IEC 60947-4-1 |
1 NO + 1 NC | 1 NO + 1 NC |
Signal loop frequency | 25…400Hz | 25…400Hz | 25…400Hz |
Minimum switching current [Imin] | 5 mA for signal loop | 5 mA for signal loop | 5 mA for signal loop |
Insulation resistance | > 10 MΩ for signal loops | > 10 MΩ for signal loops | > 10 MΩ for signal loops |
non-overlapping time | 1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
1.5 ms between de-energized NC and NO contacts 1.5 ms between energized NC and NO contacts |
installation method | Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
environment | |||
standard | IEC 60947-4-1 GB 14048.4 |
GB 14048.4 IEC 60947-4-1 |
GB 14048.4 IEC 60947-4-1 |
certified product | CCC UKCA CE |
CCC UKCA CE |
CCC UKCA CE |
IP protection class | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 | IP2x front panel for main circuits conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 | TH conforms to IEC 60068-2-30 |
ambient air temperature | -40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
-40…60 °C operation 60…70 °C with derating -60…80 °C storage |
working altitude | 3000 m None | 3000 m None | 3000 m None |
Fire resistance and abnormal high temperature resistance | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 | 850 °C conforming to IEC 60695-2-11 |
Shock and vibration resistance | Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27 |
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock resistance with contacts closed ( 4 gn (5…300 Hz)) conforming to IEC 60068-2-6 Shock performance 11 ms with contacts open (8 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms with contacts closed (10 gn) conforming to IEC 60068-2-27 |
high | 127mm | 127mm | 127mm |
width | 75 mm | 75 mm | 75 mm |
depth | 119 mm | 119mm | 119mm |
Product Weight | 1.4kg | 1.4kg | 1.4kg |
packaging unit | |||
Unit Type of Package 1 | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 |
Package 1 Height | 10.23cm | 10.437 cm | 10.1 cm |
Package 1 Width | 13.936 cm | 13.892 cm | 14.2 cm |
Package 1 Length | 14.167 cm | 14.154 cm | 14.45cm |
Package 1 Weight | 1.321kg | 1.321kg | 1.331kg |
Unit Type of Package 2 | S03 | S03 | S03 |
Number of Units in Package 2 | 12 | 12 | 12 |
Package 2 Height | 30.0cm | 30.0cm | 30.0cm |
Package 2 Width | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 16.431kg | 16.48kg | 16.591kg |
Unit Type of Package 3 | P06 | P06 | P06 |
Number of Units in Package 3 | 96 | 96 | 96 |
Package 3 Height | 75.0cm | 75.0cm | 75.0cm |
Package 3 Width | 60.0cm | 60.0cm | 60.0cm |
Package 3 Length | 80.0cm | 80.0cm | 80.0cm |
Package 3 Weight | 141.448kg | 141.84 kg | 142.728kg |
contract warranty | |||
Warranty | 18 months | 18 months | 18 months |
Weight | N/A |
---|---|
Dimensions | N/A |