Contact Us:
sales@inosaki.com

TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 300A – Schneider Contactors & Reversing Contactors

$ 395.12$ 423.50

Specifications

Main
Part Number LC1D300M5C LC1D300E7C LC1D300F7C
Product Series TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor
product short name LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-3AC
-1
AC-1AC
-3
AC-1AC
-3
number of poles 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 400 A 40 °C) at <= 440 V AC AC-1 for power circuits
300 A 40 °C) at <= 440 V AC AC-3 for power circuits
400 A 40 °C) at <= 440 V AC AC-1 for power circuits
300 A 40 °C) at <= 440 V AC AC-3 for power circuits
400 A 40 °C) at <= 440 V AC AC-1 for power circuits
300 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 230V AC 50Hz 48 V AC 50/60 Hz 110V AC 50/60Hz
Additional information
Motor power (kW) 100 kW at 220/240 V AC 50/60 Hz (AC-3)
160 kW at 380/400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 660/690 V AC 50 /60 Hz (AC-3)
160 kW at 1000 V AC 50/60 Hz (AC-3)
100 kW at 220/240 V AC 50/60 Hz (AC-3)
160 kW at 380/400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 660/690 V AC 50 /60 Hz (AC-3)
160 kW at 1000 V AC 50/60 Hz (AC-3)
100 kW at 220/240 V AC 50/60 Hz (AC-3)
160 kW at 380/400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 660/690 V AC 50 /60 Hz (AC-3)
160 kW at 1000 V AC 50/60 Hz (AC-3)
model LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO
protection cap None None None
Conventional thermal current [Ith] 400 A at <40 °C for power circuits 400 A at <40 °C for power circuits 400 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 2650 A at <40 °C – 10 s for power circuit
1800 A at <40 °C – 30 s for power circuit
1300 A at <40 °C – 1 min for power circuit
900 A at <40 °C – 3 minutes for power circuit
750 A at <40 °C – 10 minutes for power circuit
2650 A at <40 °C – 10 s for power circuit
1800 A at <40 °C – 30 s for power circuit
1300 A at <40 °C – 1 min for power circuit
900 A at <40 °C – 3 minutes for power circuit
750 A at <40 °C – 10 minutes for power circuit
2650 A at <40 °C – 10 s for power circuit
1800 A at <40 °C – 30 s for power circuit
1300 A at <40 °C – 1 min for power circuit
900 A at <40 °C – 3 minutes for power circuit
750 A at <40 °C – 10 minutes for power circuit
Fuses for use with relays 400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
average impedance 0.28 mΩ – Ith 400 A 50 Hz for power circuits 0.28 mΩ – Ith 400 A 50 Hz for power circuits 0.28 mΩ – Ith 400 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III
pollution level 3 3 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947
Mechanical life 8 Mcycles 8 Mcycles 8 Mcycles
Electrical life 0.5 Mcycles 400 A AC-1 Ue <= 440 V
1 Mcycles 300 A AC-3 Ue <= 440 V
0.9 Mcycles 220 A AC-3 Ue 660/690 V
0.5 Mcycles 400 A AC-1 Ue <= 440 V
1 Mcycles 300 A AC-3 Ue <= 440 V
0.9 Mcycles 220 A AC-3 Ue 660/690 V
0.5 Mcycles 400 A AC-1 Ue <= 440 V
1 Mcycles 300 A AC-3 Ue <= 440 V
0.9 Mcycles 220 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50 Hz AC at 50/60 Hz AC at 50/60 Hz
Control voltage limit 0.35…0.55 Uc -5…55 °C release 40…400 Hz
0.85…1.15 Uc -5…55 °C run 40…400 Hz
0.35…0.55 Uc -5…55 °C release 40…400 Hz
0.85…1.15 Uc -5…55 °C run 40…400 Hz
0.35…0.55 Uc -5…55 °C release 40…400 Hz
0.85…1.15 Uc -5…55 °C run 40…400 Hz
(~50Hz pickup) power consumption (VA) 650VA 50Hz (0.920°C) 805 VA 50 Hz 0.3 20 °C)
970 VA 60 Hz 0.3 20 °C)
650 VA 50 Hz 0.9 20 °C)
650 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 10VA 50Hz (0.920°C) 10VA 50Hz 0.9 20°C)
10VA 60Hz 0.9 20°C)
10VA 50Hz 0.9 20°C)
10VA 60Hz 0.9 20°C)
heat dissipation 8W 8W 8W
action time 40…65 ms closed
100…170 ms open
40…65 ms closed
100…170 ms open
40…65 ms closed
100…170 ms open
operating frequency 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Tightening torque Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Auxiliary contact type Does not contain Does not contain Does not contain
installation method Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
environment
standard IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
CCC
CE
CCC
CE
IP protection class IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance for 11 ms contact Heads open (6 gn) conforming to IEC 60068-2-27
Shock resistance Contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance for 11 ms contact Heads open (6 gn) conforming to IEC 60068-2-27
Shock resistance Contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance for 11 ms contact Heads open (6 gn) conforming to IEC 60068-2-27
Shock resistance Contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
high 206 mm 206 mm 206 mm
width 213mm 213 mm 213 mm
depth 219 mm 219 mm 219 mm
Product Weight 9.35kg 9.35kg 9.35kg
packaging unit
Unit Type of Package 1 PCE PCE PCE
Number of Units in Package 1 1 1 1
Package 1 Height 26.0cm 26.0cm 26.0cm
Package 1 Width 25.0cm 25.0cm 25.0cm
Package 1 Length 30.0cm 30.0cm 30.0cm
Package 1 Weight 9600.0g 9600.0g 9600.0g
Unit Type of Package 2 P06 P06 P06
Number of Units in Package 2 10 10 10
Package 2 Height 67.0cm 67.0cm 67.0cm
Package 2 Width 60.0cm 60.0cm 60.0cm
Package 2 Length 80.0cm 80.0cm 80.0cm
Package 2 Weight 106.0 kg 106.0 kg 106.0 kg
contract warranty
Warranty 18 months 18 months 18 months

 

Main
Part Number LC1D300M7C LC1D300Q7C
Product Series TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca
product type Contactor Contactor
product short name LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-1AC
-3
AC-1AC
-3
number of poles 3P 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 400 A 40 °C) at <= 440 V AC AC-1 for power circuits
300 A 40 °C) at <= 440 V AC AC-3 for power circuits
400 A 40 °C) at <= 440 V AC AC-1 for power circuits
300 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 230V AC 50/60Hz 380 V AC 50/60 Hz
Additional information
Motor power (kW) 100 kW at 220/240 V AC 50/60 Hz (AC-3)
160 kW at 380/400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 660/690 V AC 50 /60 Hz (AC-3)
160 kW at 1000 V AC 50/60 Hz (AC-3)
100 kW at 220/240 V AC 50/60 Hz (AC-3)
160 kW at 380/400 V AC 50/60 Hz (AC-3)
180 kW at 415 V AC 50/60 Hz (AC-3)
200 kW at 440 V AC 50/60 Hz (AC-3)
200 kW at 500 V AC 50/60 Hz (AC-3)
220 kW at 660/690 V AC 50 /60 Hz (AC-3)
160 kW at 1000 V AC 50/60 Hz (AC-3)
model LC1D LC1D
Loop contact type 3 NO 3 NO
protection cap None None
Conventional thermal current [Ith] 400 A at <40 °C for power circuits 400 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 2650 A at <40 °C – 10 s for power circuit
1800 A at <40 °C – 30 s for power circuit
1300 A at <40 °C – 1 min for power circuit
900 A at <40 °C – 3 minutes for power circuit
750 A at <40 °C – 10 minutes for power circuit
2650 A at <40 °C – 10 s for power circuit
1800 A at <40 °C – 30 s for power circuit
1300 A at <40 °C – 1 min for power circuit
900 A at <40 °C – 3 minutes for power circuit
750 A at <40 °C – 10 minutes for power circuit
Fuses for use with relays 400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
400 A aM at <= 440 V for power circuits
500 A gG at <= 440 V for power circuits
average impedance 0.28 mΩ – Ith 400 A 50 Hz for power circuits 0.28 mΩ – Ith 400 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III
pollution level 3 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947 8 kV according to IEC 60947
Mechanical life 8 Mcycles 8 Mcycles
Electrical life 0.5 Mcycles 400 A AC-1 Ue <= 440 V
1 Mcycles 300 A AC-3 Ue <= 440 V
0.9 Mcycles 220 A AC-3 Ue 660/690 V
0.5 Mcycles 400 A AC-1 Ue <= 440 V
1 Mcycles 300 A AC-3 Ue <= 440 V
0.9 Mcycles 220 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50/60 Hz AC at 50/60 Hz
Control voltage limit 0.35…0.55 Uc -5…55 °C release 40…400 Hz
0.85…1.15 Uc -5…55 °C run 40…400 Hz
0.35…0.55 Uc -5…55 °C release 40…400 Hz
0.85…1.15 Uc -5…55 °C run 40…400 Hz
(~50Hz pickup) power consumption (VA) 650 VA 50 Hz 0.9 20 °C)
650 VA 60 Hz 0.9 20 °C)
650 VA 50 Hz 0.9 20 °C)
650 VA 60 Hz 0.9 20 °C)
(~50Hz hold) power consumption (VA) 10VA 50Hz 0.9 20°C)
10VA 60Hz 0.9 20°C)
10VA 50Hz 0.9 20°C)
10VA 60Hz 0.9 20°C)
heat dissipation 8W 8W
action time 40…65 ms closed
100…170 ms open
40…65 ms closed
100…170 ms open
operating frequency 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Solid wire without wire terminals Power
circuit: Bus bar terminals
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Cable with lug Cable selection: Stranded wire with wire Wire terminals
Control circuit: Bolt fastening Cable selection: Single solid wire without wire terminals
Power circuit: Bus terminal
Tightening torque Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Control circuit: 1.2 Nm Power circuit via bolt fastening : 35 Nm
Power circuit via busbar terminals: 35 Nm via cable connector
Auxiliary contact type Does not contain Does not contain
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
environment
standard GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
CCC
CE
IP protection class IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance for 11 ms contact Heads open (6 gn) conforming to IEC 60068-2-27
Shock resistance Contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance for 11 ms contact Heads open (6 gn) conforming to IEC 60068-2-27
Shock resistance Contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
high 206 mm 206 mm
width 213mm 213 mm
depth 219 mm 219 mm
Product Weight 9.35kg 9.35kg
packaging unit
Unit Type of Package 1 PCE PCE
Number of Units in Package 1 1 1
Package 1 Height 25.8 cm 25.156 cm
Package 1 Width 24.5cm 25.938 cm
Package 1 Length 30.1 cm 30.213 cm
Package 1 Weight 9.0 kg 9.181 kg
Unit Type of Package 2 PAL PAL
Number of Units in Package 2 10 10
Package 2 Height 46.0cm 46.0cm
Package 2 Width 60.0cm 60.0cm
Package 2 Length 80.0cm 80.0cm
Package 2 Weight 93.39 kg 94.1kg
contract warranty
Warranty 18 months 18 months

 

Additional information

Weight N/A
Dimensions N/A

Related Products

SICK_sensor_Plug-connectors-and-cables_YF2A14-100VB3XLEAX
Schneider_Safety Switches_XCSPR751
INOSAKI-SICK-Photoelectric-Sensors_WL9G-3P2432
IDS Camera IDS imaging ueye camera
M2
$ 5.19 - $ 5.39
panasonic FPΣ Expansion unit
Select your currency