TeSys Deca – LC1D – 3 Poles (3NO) Contactor, 205A – Schneider Contactors & Reversing Contactors

$ 222.86$ 240.24

SKU: N/A

Specifications

Main
Part Number LC1D205E5C LC1D205E7C LC1D205F5C LC1D205F7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
use category AC-1AC
-3
AC-1AC
-3
AC-1AC
-3
AC-1AC
-3
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 48V AC 50Hz 48 V AC 50/60 Hz 110V AC 50Hz 110V AC 50/60Hz
Additional information
Motor power (kW) 100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
protection cap None None None None
Conventional thermal current [Ith] 275 A at <40 °C for power circuits 275 A at <40 °C for power circuits 275 A at <40 °C for power circuits 275 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
Fuses for use with relays 200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
average impedance 0.33 mΩ – Ith 275 A 50 Hz for power circuits 0.33 mΩ – Ith 275 A 50 Hz for power circuits 0.33 mΩ – Ith 275 A 50 Hz for power circuits 0.33 mΩ – Ith 275 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947
Mechanical life 8 Mcycles 8 Mcycles 8 Mcycles 8 Mcycles
Electrical life 0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50 Hz AC at 50/60 Hz AC at 50 Hz AC at 50/60 Hz
Control voltage limit 0.85…1.15 Uc -5…55 °C operating 50 Hz
0.35…0.55 Uc -5…55 °C releasing 50 Hz
0.35…0.55 Uc -5…55 °C release 50/60 Hz
0.85…1.15 Uc -5…55 °C run 50/60 Hz
0.85…1.15 Uc -5…55 °C operating 50 Hz
0.35…0.55 Uc -5…55 °C releasing 50 Hz
0.35…0.55 Uc -5…55 °C release 50/60 Hz
0.85…1.15 Uc -5…55 °C run 50/60 Hz
(~50Hz pickup) power consumption (VA) 805VA 50Hz (0.320°C) 805 VA 50 Hz 0.3 20 °C)
970 VA 60 Hz 0.3 20 °C)
805VA 50Hz (0.320°C) 805 VA 50 Hz 0.3 20 °C)
970 VA 60 Hz 0.3 20 °C)
(~50Hz hold) power consumption (VA) 55VA 50Hz (0.320°C) 55 VA 50 Hz 0.3 20 °C)
66 VA 60 Hz 0.3 20 °C)
55VA 50Hz (0.320°C) 55 VA 50 Hz 0.3 20 °C)
66 VA 60 Hz 0.3 20 °C)
heat dissipation 18…24W 18…24W 18…24W 18…24W
action time 20…35 ms closed
7…15 ms open
20…35 ms closed
7…15 ms open
20…35 ms closed
7…15 ms open
20…35 ms closed
7…15 ms open
operating frequency 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C
Wiring capacity Power circuit: busbar terminal 2 Cable option: solid busbar cross-section: 25 x 3 mm
Power circuit: cable with lug1 150 mm² Cable option:
stranded wire with wire terminal 150 mm² Cable selection: Stranded wire with wire terminals
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminals
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminals
Control circuit: Bolt Fastening cable selection: hard wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal Power
circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Tightening torque Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Auxiliary contact type Does not contain Does not contain Does not contain Does not contain
installation method DIN rail installation
base plate installation
Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
environment
standard GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
certified product CCC
CE
CCC
CE
CCC
CE
CCC
CE
IP protection class IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None 3000 m None
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
high 174 mm 174 mm 174 mm 174 mm
width 168.5 mm 168.5mm 168.5mm 168.5mm
depth 181 mm 181 mm 181 mm 181 mm
Product Weight 5.2kg 5.2kg 5.2kg 5.2kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 21cm 21.0cm 21.0cm 21.0cm
Package 1 Width 22cm 22.0cm 22.0cm 22.0cm
Package 1 Length 23.5cm 23.5cm 23.5cm 23.5cm
Package 1 Weight 5000g 5101.0g 5101.0g 5081.0g
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

main information
Part Number LC1D205M5C LC1D205M7C LC1D205Q5C LC1D205Q7C
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
Product Series TeSys Deca TeSys Deca TeSys Deca TeSys Deca
product type Contactor Contactor Contactor Contactor
product short name LC1D LC1D LC1D LC1D
Application field of contactor Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to AC loads with power factor greater than or equal to 0.95
Applied to non-inductive or slightly inductive loads, resistance furnaces
Applied to non-inductive or micro-inductive loads, and
resistance furnaces to AC loads with a power factor greater than or equal to 0.95
use category AC-3AC
-1
AC-3AC
-1
AC-3AC
-1
AC-1AC
-3
number of poles 3P 3P 3P 3P
Rated working voltage [Ue] Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Power circuit: <= 1000 V AC 25…400 Hz
Power circuit: <= 460 V DC
Rated operating current [Ie] 275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
275 A 40 °C) at <= 440 V AC AC-1 for power circuits
205 A 40 °C) at <= 440 V AC AC-3 for power circuits
[Uc] control circuit voltage 230V AC 50Hz 230V AC 50/60Hz 380V AC 50Hz 380 V AC 50/60 Hz
Additional information
Motor power (kW) 100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
100 kW at 1000 V AC 50/60 Hz (AC-3)
63 kW at 220/240 V AC 50/60 Hz (AC-3)
110 kW at 380/400 V AC 50/60 Hz (AC-3)
110 kW at 415 V AC 50/60 Hz (AC-3)
110 kW at 440 V AC 50/60 Hz (AC-3)
129 kW at 500 V AC 50/60 Hz (AC-3)
129 kW at 660/690 V AC 50/60 Hz (AC-3)
model LC1D LC1D LC1D LC1D
Loop contact type 3 NO 3 NO 3 NO 3 NO
protection cap None None None None
Conventional thermal current [Ith] 275 A at <40 °C for power circuits 275 A at <40 °C for power circuits 275 A at <40 °C for power circuits 275 A at <40 °C for power circuits
Rated short-time withstand current [Icw] 1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
1500 A at <40 °C – 10 s for power circuit
920 A at <40 °C – 30 s for power circuit
740 A at <40 °C – 1 min for power circuit
500 A at <40 °C – 3 minutes for power circuit
400 A at <40 °C – 10 minutes for power circuit
Fuses for use with relays 200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
200 A aM at <= 440 V for power circuits
315 A gG at <= 440 V for power circuits
average impedance 0.33 mΩ – Ith 275 A 50 Hz for power circuits 0.33 mΩ – Ith 275 A 50 Hz for power circuits 0.33 mΩ – Ith 275 A 50 Hz for power circuits 0.33 mΩ – Ith 275 A 50 Hz for power circuits
Rated insulation voltage [Ui] Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1 Power circuit: 1000 V conforming to IEC 60947-4-1
Overvoltage category III III III III
pollution level 3 3 3 3
Rated impulse withstand voltage [Uimp] 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947 8 kV according to IEC 60947
Mechanical life 8 Mcycles 8 Mcycles 8 Mcycles 8 Mcycles
Electrical life 0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
0.55 Mcycles 275 A AC-1 Ue <= 440 V
1.1 Mcycles 170 A AC-3 Ue <= 440 V
1 Mcycles 118 A AC-3 Ue 660/690 V
Control loop characteristics AC at 50 Hz AC at 50/60 Hz AC at 50 Hz AC at 50/60 Hz
Control voltage limit 0.85…1.15 Uc -5…55 °C operating 50 Hz
0.35…0.55 Uc -5…55 °C releasing 50 Hz
0.35…0.55 Uc -5…55 °C release 50/60 Hz
0.85…1.15 Uc -5…55 °C run 50/60 Hz
0.85…1.15 Uc -5…55 °C operating 50 Hz
0.35…0.55 Uc -5…55 °C releasing 50 Hz
0.35…0.55 Uc -5…55 °C release 50/60 Hz
0.85…1.15 Uc -5…55 °C run 50/60 Hz
(~50Hz pickup) power consumption (VA) 805VA 50Hz (0.320°C) 805 VA 50 Hz 0.3 20 °C)
970 VA 60 Hz 0.3 20 °C)
805VA 50Hz (0.320°C) 805 VA 50 Hz 0.3 20 °C)
970 VA 60 Hz 0.3 20 °C)
(~50Hz hold) power consumption (VA) 55VA 50Hz (0.320°C) 55 VA 50 Hz 0.3 20 °C)
66 VA 60 Hz 0.3 20 °C)
55VA 50Hz (0.320°C) 55 VA 50 Hz 0.3 20 °C)
66 VA 60 Hz 0.3 20 °C)
heat dissipation 18…24W 18…24W 18…24W 18…24W
action time 20…35 ms closed
7…15 ms open
20…35 ms close
130 ms break
20…35 ms closed
7…15 ms open
20…35 ms closed
7…15 ms open
operating frequency 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C 2400 cycles/h at <55 °C
Wiring capacity Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire without wire terminal
Control circuit: Bolt fastening Cable selection: Flexible wire with wire terminal
Power circuit: Bus terminal Cable selection: Hard wire without wire terminal Busbar Cross-section: 25 x 3 mm Power
circuit:
Cable with
lugs Cable selection: single-strand hard wire without wire terminal
Tightening torque Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Power circuit: 18 Nm Via busbar terminals
Power circuit: 18 Nm Via cable connector
Control circuit: 1.2 Nm Via bolt fastening
Auxiliary contact type Does not contain Does not contain Does not contain Does not contain
installation method Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
Chassis mounting
rail installation
environment
standard IEC 60947-4-1
GB 14048.4
GB 14048.4
IEC 60947-4-1
GB 14048.4
IEC 60947-4-1
IEC 60947-4-1
GB 14048.4
certified product CCC
CE
CCC
CE
CCC
CE
CCC
CE
IP protection class IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529 IP20 front panel with LA9F conforming to IEC 60529
Protective measures TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30 TH conforms to IEC 60068-2-30
ambient air temperature -40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
-40…60 °C operation
60…70 °C with derating
-60…80 °C storage
working altitude 3000 m None 3000 m None 3000 m None 3000 m None
Shock and vibration resistance Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
Shock resistance with contacts open (2 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance for 11 ms with contacts closed (15 gn) conforming to IEC 60068-2-27
Shock resistance with contacts closed (5 gn (5…300 Hz)) conforming to IEC 60068-2-6
Shock resistance 11 ms contact opening (7 gn) conforming to IEC 60068-2-27
high 174 mm 174 mm 174 mm 174 mm
width 168.5mm 168.5mm 168.5mm 168.5mm
depth 181 mm 181 mm 181 mm 181 mm
Product Weight 5.2kg 5.2kg 5.2kg 5.2kg
packaging unit
Unit Type of Package 1 PCE PCE PCE PCE
Number of Units in Package 1 1 1 1 1
Package 1 Height 21.9 cm 21.7cm 22.4 cm 21.221 cm
Package 1 Width 23.2 cm 21.7cm 21.9 cm 22.361 cm
Package 1 Length 22.2 cm 23.3 cm 23.4 cm 23.622 cm
Package 1 Weight 4.967kg 4.859 kg 4.952 kg 4.961 kg
Unit Type of Package 2 PAL PAL PAL PAL
Number of Units in Package 2 12 12 12 12
Package 2 Height 42.0cm 42.0cm 42.0cm 42.0cm
Package 2 Width 60.0cm 60.0cm 60.0cm 60.0cm
Package 2 Length 80.0cm 80.0cm 80.0cm 80.0cm
Package 2 Weight 95.364 kg 95.706 kg 95.274 kg 93.6 kg
contract warranty
Warranty 18 months 18 months 18 months 18 months

 

Weight N/A
Dimensions N/A

Related products