$ 15.41 – $ 34.04Price range: $ 15.41 through $ 34.04
| Main | ||||
| Part Number |
CAD50B7C |
CAD50BDC |
CAD50CC7C |
CAD50E7C |
| Product Series | TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
| product name | TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
| product type | Control relay | Control relay | Control relay | Control relay |
| product short name | CAD | CAD | CAD | CAD |
| Application field of contactor | Control loop | Control loop | Control loop | Control loop |
| use category | DC-13 AC-15 AC-14 |
DC-13 AC-14 AC-15 |
AC-15 AC-14 DC-13 |
AC-14 AC-15 DC-13 |
| Loop contact type | 5 NO | 5 NO | 5 NO | 5 NO |
| Control circuit voltage | 24 V AC 50/60 Hz | 24 V DC | 36 V AC 50/60 Hz | 48 V AC 50/60 Hz |
| Additional information | ||||
| Rated working voltage [Ue] | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz |
| Mechanical life | 30 Mcycles | 30 Mcycles | 30 Mcycles | 30 Mcycles |
| operating frequency | 180 times/min | 180 times/min | 180 times/min | 180 times/min |
| action time | 12…22 ms coil energization and NO contact closure 4…12 ms coil discharge and NO opening |
50…55 ms coil energization and NO contact closure 6…14 ms coil discharge and NO opening |
12…22 ms coil energization and NO contact closure 4…12 ms coil discharge and NO opening |
12…22 ms coil energization and NO contact closure 4…12 ms coil discharge and NO opening |
| Control voltage limit | Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Running: 0.7…1.25 Uc Release: 0.1…0.25 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
| (~50Hz hold) power consumption (VA) | 8VA 50Hz 20°C) | N/A | 8VA 50Hz 20°C) | 8VA 50Hz 20°C) |
| (~50Hz pickup) power consumption (VA) | 70VA 50Hz 20°C) | 70VA 50Hz 20°C) | 70VA 50Hz 20°C) | |
| Conventional thermal current [Ith] | 10 A at <40 °C | 10 A at <40 °C | 10 A at <40 °C | 10 A at <40 °C |
| Rated making capacity [Irms] | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
| Rated short-time withstand current [Icw] | 100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
| Fuses for use with relays | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 |
| Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 |
| Insulation resistance | > 10 MΩ | > 10 MΩ | > 10 MΩ | > 10 MΩ |
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
| Minimum switching current [Imin] | 5 mA | 5 mA | 5 mA | 5 mA |
| Minimum switching capacity [U min] | 17V | 17V | 17V | 17V |
| non-overlapping time | 1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
| installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
| Wiring capacity | Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
| Tightening torque | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts |
| high | 77 mm | 77 mm | 77 mm | 77 mm |
| width | 45 mm | 45 mm | 45 mm | 45 mm |
| depth | 84 mm | 93 mm | 84 mm | 84 mm |
| Product Weight | 580g | 580g | 580g | 580g |
| environment | ||||
| Standards compliant | GB 14048.5 IEC 60947-5-1 |
IEC 60947-5-1 GB 14048.5 |
GB 14048.5 IEC 60947-5-1 |
IEC 60947-5-1 GB 14048.5 |
| certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
| quality mark | CE declaration | CE declaration | CE declaration | CE declaration |
| IP protection class | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 |
| Protective measures | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 |
| operating temperature | -40…70°C | -40…70°C | -40…70°C | -40…70°C |
| storage environment temperature | -60…80°C | -60…80°C | -60…80°C | -60…80°C |
| working altitude | 3000m | 3000m | 3000m | 3000m |
| Shock and vibration resistance | Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
| packaging unit | ||||
| Unit Type of Package 1 | PCE | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 | 1 |
| Package 1 Height | 8.0cm | 5.376 cm | 8cm | 8.0cm |
| Package 1 Width | 9.3 cm | 7.884 cm | 9.3 cm | 9.3 cm |
| Package 1 Length | 5.2 cm | 10.441 cm | 5.2 cm | 5.2 cm |
| Package 1 Weight | 357.88g | 510.0g | 334.4g | 385.4g |
| Unit Type of Package 2 | CAR | S02 | N/A | CAR |
| Number of Units in Package 2 | Twenty four | Twenty one | Twenty four | |
| Package 2 Height | 30.0cm | 15.0cm | 30.0cm | |
| Package 2 Width | 40.0cm | 30.0cm | 40.0cm | |
| Package 2 Length | 15.0cm | 40.0cm | 15.0cm | |
| Package 2 Weight | 8.639 kg | 11.2kg | 9.3 kg | |
| Unit Type of Package 3 | PAL | PAL | PAL | |
| Number of Units in Package 3 | 384 | 336 | 384 | |
| Package 3 Height | 60.0cm | 60.0cm | 60.0cm | |
| Package 3 Width | 80.0cm | 80.0cm | 80.0cm | |
| Package 3 Length | 75.0cm | 75.0cm | 75.0cm | |
| Package 3 Weight | 137.624 kg | 184.16kg | 148.194 kg | |
| contract warranty | ||||
| Warranty | 18 months | 18 months | 18 months | 18 months |
| Main | |||
| Part Number |
CAD50F7C |
CAD50M7C |
CAD50Q7C |
| Product Series | TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
| product name | TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
| product type | Control relay | Control relay | Control relay |
| product short name | CAD | CAD | CAD |
| Application field of contactor | Control loop | Control loop | Control loop |
| use category | DC-13 AC-14 AC-15 |
DC-13 AC-15 AC-14 |
AC-15 AC-14 DC-13 |
| Loop contact type | 5 NO | 5 NO | 5 NO |
| Control circuit voltage | 110V AC 50/60Hz | 230V AC 50/60Hz | 380 V AC 50/60 Hz |
| Additional information | |||
| Rated working voltage [Ue] | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz |
| Mechanical life | 30 Mcycles | 30 Mcycles | 30 Mcycles |
| operating frequency | 180 times/min | 180 times/min | 180 times/min |
| action time | 12…22 ms coil energization and NO contact closure 4…12 ms coil discharge and NO opening |
12…22 ms coil energization and NO contact closure 4…12 ms coil discharge and NO opening |
12…22 ms coil energization and NO contact closure 4…12 ms coil discharge and NO opening |
| Control voltage limit | Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
| (~50Hz hold) power consumption (VA) | 8VA 50Hz 20°C) | 8VA 50Hz 20°C) | 8VA 50Hz 20°C) |
| (~50Hz pickup) power consumption (VA) | 70VA 50Hz 20°C) | 70VA 50Hz 20°C) | 70VA 50Hz 20°C) |
| Conventional thermal current [Ith] | 10 A at <40 °C | 10 A at <40 °C | 10 A at <40 °C |
| Rated making capacity [Irms] | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
| Rated short-time withstand current [Icw] | 100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
| Fuses for use with relays | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 |
| Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 |
| Insulation resistance | > 10 MΩ | > 10 MΩ | > 10 MΩ |
| Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
| Minimum switching current [Imin] | 5 mA | 5 mA | 5 mA |
| Minimum switching capacity [U min] | 17V | 17V | 17V |
| non-overlapping time | 1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
| installation method | DIN rail installation base plate installation |
DIN rail installation base plate installation |
Chassis mounting rail installation |
| Wiring capacity | Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
| Tightening torque | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts |
| high | 77 mm | 77 mm | 77 mm |
| width | 45 mm | 45 mm | 45 mm |
| depth | 84 mm | 84 mm | 84mm |
| Product Weight | 580g | 580g | 580g |
| environment | |||
| Standards compliant | GB 14048.5 IEC 60947-5-1 |
GB 14048.5 IEC 60947-5-1 |
IEC 60947-5-1 GB 14048.5 |
| certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
| quality mark | CE declaration | CE declaration | CE declaration |
| IP protection class | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 |
| Protective measures | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 |
| operating temperature | -40…70°C | -40…70°C | -40…70°C |
| storage environment temperature | -60…80°C | -60…80°C | -60…80°C |
| working altitude | 3000m | 3000m | 3000m |
| Shock and vibration resistance | Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
| packaging unit | |||
| Unit Type of Package 1 | PCE | PCE | PCE |
| Number of Units in Package 1 | 1 | 1 | 1 |
| Package 1 Height | 5.211 cm | 5.13cm | 8.0cm |
| Package 1 Width | 7.865 cm | 7.67cm | 9.3 cm |
| Package 1 Length | 9.446 cm | 9.28cm | 5.2 cm |
| Package 1 Weight | 341.0g | 349.0g | 370.21g |
| Unit Type of Package 2 | S02 | S02 | CAR |
| Number of Units in Package 2 | Twenty four | Twenty four | Twenty four |
| Package 2 Height | 15.0cm | 15.0cm | 30.0cm |
| Package 2 Width | 30.0cm | 30.0cm | 40.0cm |
| Package 2 Length | 40.0cm | 40.0cm | 15.0cm |
| Package 2 Weight | 8.73kg | 8.762kg | 8.935 kg |
| Unit Type of Package 3 | PAL | PAL | PAL |
| Number of Units in Package 3 | 384 | 384 | 384 |
| Package 3 Height | 60.0cm | 60.0cm | 60.0cm |
| Package 3 Width | 80.0cm | 80.0cm | 80.0cm |
| Package 3 Length | 75.0cm | 75.0cm | 75.0cm |
| Package 3 Weight | 142.64kg | 145.728 kg | 142.36kg |
| contract warranty | |||
| Warranty | 18 month | 18 months | 18 months |