Main | ||||
Part Number |
CAD32B7C |
CAD32BDC |
CAD32E7C |
CAD32F7C |
Product Series | TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
product name | TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
product type | Control relay | Control relay | Control relay | Control relay |
product short name | CAD | CAD | CAD | CAD |
Application field of contactor | Control loop | Control loop | Control loop | Control loop |
use category | AC-14 AC-15 DC-13 |
AC-14 DC-13 AC-15 |
AC-15 DC-13 AC-14 |
AC-14 DC-13 AC-15 |
Loop contact type | 3 NO + 2 NC | 3 NO + 2 NC | 3 NO + 2 NC | 3 NO + 2 NC |
Control circuit voltage | 24 V AC 50/60 Hz | 24 V DC | 48 V AC 50/60 Hz | 110V AC 50/60Hz |
Additional information | ||||
Rated working voltage [Ue] | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz |
Mechanical life | 30 Mcycles | 30 Mcycles | 30 Mcycles | 30 Mcycles |
operating frequency | 180 times/min | 180 times/min | 180 times/min | 180 times/min |
action time | 12…22 ms Coil energizes and NO contact closes 4…12 ms Coil discharges and NO opens 4…19 ms Coil energizes and NC contacts open 6…17 ms Coil deenergizes and NC closure |
50…55 ms Coil energizes and NO contact closes 6…14 ms Coil discharges and NO opens 35…45 ms Coil energizes and NC contacts open 20 ms Coil deenergizes and NC closes |
12…22 ms Coil energizes and NO contact closes 4…12 ms Coil discharges and NO opens 4…19 ms Coil energizes and NC contacts open 6…17 ms Coil deenergizes and NC closure |
12…22 ms Coil energizes and NO contact closes 4…12 ms Coil discharges and NO opens 4…19 ms Coil energizes and NC contacts open 6…17 ms Coil deenergizes and NC closure |
Control voltage limit | Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Running: 0.7…1.25 Uc Release: 0.1…0.25 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
(~50Hz hold) power consumption (VA) | 8VA 50Hz 20°C) | N/A | 8VA 50Hz 20°C) | 8VA 50Hz 20°C) |
(~50Hz pickup) power consumption (VA) | 70VA 50Hz 20°C) | 70VA 50Hz 20°C) | 70VA 50Hz 20°C) | |
Conventional thermal current [Ith] | 10 A at <40 °C | 10 A at <40 °C | 10 A at <40 °C | 10 A at <40 °C |
Rated making capacity [Irms] | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
Rated short-time withstand current [Icw] | 100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
Fuses for use with relays | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 |
Rated insulation voltage [Ui] | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 |
Insulation resistance | > 10 MΩ | > 10 MΩ | > 10 MΩ | > 10 MΩ |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Minimum switching current [Imin] | 5 mA | 5 mA | 5 mA | 5 mA |
Minimum switching capacity [U min] | 17V | 17V | 17V | 17V |
non-overlapping time | 1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
Wiring capacity | Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Tightening torque | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts |
high | 77 mm | 77 mm | 77 mm | 77 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 84 mm | 93 mm | 84 mm | 84 mm |
Product Weight | 580g | 580g | 580g | 580g |
environment | ||||
Standards compliant | IEC 60947-5-1 GB 14048.5 |
GB 14048.5 IEC 60947-5-1 |
IEC 60947-5-1 GB 14048.5 |
IEC 60947-5-1 GB 14048.5 |
certified product | CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
quality mark | CE declaration | CE declaration | CE declaration | CE declaration |
IP protection class | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 |
operating temperature | -40…70°C | -40…70°C | -40…70°C | -40…70°C |
storage environment temperature | -60…80°C | -60…80°C | -60…80°C | -60…80°C |
working altitude | 3000m | 3000m | 3000m | 3000m |
Shock and vibration resistance | Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5.185 cm | 5.12cm | 5.24cm | 5.8cm |
Package 1 Width | 7.895 cm | 7.754 cm | 7.77cm | 8.3 cm |
Package 1 Length | 9.453 cm | 10.091 cm | 9.28cm | 9.6cm |
Package 1 Weight | 350.0g | 522g | 355.0g | 356.0g |
Unit Type of Package 2 | S02 | CAR | S02 | S02 |
Number of Units in Package 2 | Twenty four | Twenty one | Twenty four | Twenty four |
Package 2 Height | 15cm | 30cm | 15cm | 15cm |
Package 2 Width | 30cm | 40cm | 30cm | 30cm |
Package 2 Length | 40cm | 15cm | 40cm | 40cm |
Package 2 Weight | 8.91kg | 11410g | 8.95kg | 8.873kg |
Unit Type of Package 3 | PAL | PAL | PAL | PAL |
Number of Units in Package 3 | 384 | 336 | 384 | 384 |
Package 3 Height | 60cm | 60cm | 60cm | 60cm |
Package 3 Width | 80.0cm | 80cm | 80cm | 80cm |
Package 3 Length | 75cm | 75cm | 75cm | 75cm |
Package 3 Weight | 144.448kg | 182560g | 137.836kg | 145.344kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |
Main | ||||
Part Number |
CAD32FD |
CAD32FDC |
CAD32M7C |
CAD32MDC |
Product Series | TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
TeSys TeSys Deca |
product name | TeSys CAD | TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
TeSys CAD TeSys Deca |
product type | Control relay | Control relay | Control relay | Control relay |
product short name | CAD | CAD | CAD | CAD |
Application field of contactor | Control loop | Control loop | Control loop | Control loop |
Additional information | ||||
use category | AC-15 DC-13 AC-14 |
DC-13 AC-14 AC-15 |
AC-14 AC-15 DC-13 |
AC-15 AC-14 DC-13 |
Loop contact type | 3 NO + 2 NC | 3 NO + 2 NC | 3 NO + 2 NC | 3 NO + 2 NC |
Rated working voltage [Ue] | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz | <= 690 V AC 25…400 Hz |
Control loop characteristics | DC standard | N/A | ||
Control circuit voltage | 110VDC | 110VDC | 230V AC 50/60Hz | 230V DC |
Rated impulse withstand voltage [Uimp] | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 | 6 kV according to IEC 60947 |
Conventional thermal current [Ith] | 10 A at <60 °C | 10 A at <40 °C | 10 A at <40 °C | 10 A at <40 °C |
Rated making capacity [Irms] | 140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1 |
Rated short-time withstand current [Icw] | 100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
100 A – 1 s 120 A – 500 ms 140 A – 100 ms |
Fuses for use with relays | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 | 10 A gG conforming to IEC 60947-5-1 |
Rated insulation voltage [Ui] | 600 V UL Listed 600 V CSA Listed 690 V Conforms to IEC 60947-5-1 |
690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 | 690 V conforming to IEC 60947-5-1 |
installation method | DIN rail installation base plate installation |
Chassis mounting rail installation |
Chassis mounting rail installation |
DIN rail installation base plate installation |
Wiring capacity | Bolt fastening1 Cable 1…4 mm² flexible without bolt fastening2 Cable 1…4 mm² flexible without bolt fastening1 Cable 1…4 mm² flexible with bolt fastening2 Cable 1…2.5 mm² flexible with bolt fastening Screw fastening1 cable 1…4 mm² solid without screw fastening2 cable 1…4 mm² solid without screw fastening |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Screw-on1 1…4 mm² Cable option: Flexible without cable terminal Screw-on2 1…4 mm² Cable option: Flexible without cable terminal Screw-on1 1…4 mm² Cable option: Flexible wire with screw terminal 2 1…2.5 mm² Cable selection: flexible wire with screw terminal 1 1…4 mm² Cable selection: solid wire without screw terminal 2 1 …4 mm² Cable option: Solid without wire terminals |
Tightening torque | 1.2 Nm Screwdriver No. 2 for screw tightening Phillips screw 1.2 Nm Screwdriver Ø 6 for screw tightening Flat 1.2 Nm Screwdriver pozidriv No. 2 for screw tightening |
1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts | 1.7 Nm tightened with bolts |
Control voltage limit | 0.1…0.25 Uc -40…70 °C release DC 0.7…1.25 Uc -40…60 °C run DC 1…1.25 Uc 60…70 °C run DC |
Running: 0.7…1.25 Uc Release: 0.1…0.25 Uc |
Operation: 0.8…1.1 Uc Operation at 50 Hz : 0.85…1.1 Uc Release at 60 Hz: 0.3…0.6 Uc |
Running: 0.7…1.25 Uc Release: 0.1…0.25 Uc |
action time | 53…72 ms coil energization and NO contact closure 16…24 ms coil discharge and NO opening 47…63 ms coil energization and NC contact opening 15…25 ms coil de-energization and NC closure |
50…55 ms Coil energizes and NO contact closes 6…14 ms Coil discharges and NO opens 35…45 ms Coil energizes and NC contacts open 20 ms Coil deenergizes and NC closes |
12…22 ms Coil energizes and NO contact closes 4…12 ms Coil discharges and NO opens 4…19 ms Coil energizes and NC contacts open 6…17 ms Coil deenergizes and NC closure |
50…55 ms Coil energizes and NO contact closes 6…14 ms Coil discharges and NO opens 35…45 ms Coil energizes and NC contacts open 20 ms Coil deenergizes and NC closes |
Mechanical life | 30 Mcycles | 30 Mcycles | 30 Mcycles | 30 Mcycles |
operating frequency | 180 times/min | 180 times/min | 180 times/min | 180 times/min |
time constant | 28ms | N/A | ||
Surge power (W) | 5.4W (20°C) | |||
Holding power consumption(W) | 5.4 W at 20 °C | |||
Minimum switching voltage | 17V | |||
Minimum switching current [Imin] | 5 mA | 5 mA | 5 mA | 5 mA |
non-overlapping time | 1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
1.5 ms between energized NC and NO contacts 1.5 ms between de-energized NC and NO contacts |
Insulation resistance | > 10 MΩ | > 10 MΩ | > 10 MΩ | > 10 MΩ |
Shock and vibration resistance | Shock resistance control relay open: 10 gn (11ms) according to IEC 60068-2-27 Shock resistance control relay closed: 15 gn (11ms) according to IEC 60068-2-27 shock resistance control relay open: 2 gn (5.. .300 Hz) conforming to IEC 60068-2-6 Shock resistance Control relay closed: 4 gn (5…300 Hz) conforming to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
Shock resistance 11 ms control relay open (10 gn) conforming to IEC 60068-2-27 Shock resistance 11 ms control relay closing (15 gn) conforming to IEC 60068-2-27 Shock resistance control relay open (2 gn (5.. .300 Hz)) according to IEC 60068-2-6 shock resistance control relay closed (4 gn (5…300 Hz)) according to IEC 60068-2-6 |
high | 77 mm | 77 mm | 77 mm | 77 mm |
width | 45 mm | 45 mm | 45 mm | 45 mm |
depth | 93 mm | 93 mm | 84mm | 93 mm |
Product Weight | 0.58 kg | 580g | 580g | 580g |
environment | ||||
standard | BS 4794 EN 60947-5 IEC 60947-5-1 NF C 63-140 VDE 0660 IEC 60335-1 |
N/A | ||
certified product | CSA UL UKCA |
CCC CE UKCA |
CCC CE UKCA |
CCC CE UKCA |
IP protection class | IP2x front panel according to VDE 0106 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 | IP2x front panel conforming to IEC 60529 |
Protective measures | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 | TH conforms to IEC 60068 |
ambient temperature | -40…60 °C 60…70 °C with derating |
N/A | ||
storage environment temperature | -60…80°C | -60…80°C | -60…80°C | -60…80°C |
working altitude | 0…3000m | 3000m | 3000m | 3000m |
packaging unit | ||||
Unit Type of Package 1 | PCE | PCE | PCE | PCE |
Number of Units in Package 1 | 1 | 1 | 1 | 1 |
Package 1 Height | 5cm | 5.9cm | 4.98cm | 5.381 cm |
Package 1 Width | 9.2 cm | 8.0cm | 7.95cm | 8.016 cm |
Package 1 Length | 11.2 cm | 10.7cm | 9.22cm | 10.37cm |
Package 1 Weight | 515g | 519.0g | 360.61g | 480.0g |
Unit Type of Package 2 | S02 | S02 | S02 | S02 |
Number of Units in Package 2 | 15 | Twenty one | Twenty four | Twenty one |
Package 2 Height | 15cm | 15.0cm | 15.0cm | 15.0cm |
Package 2 Width | 30cm | 30.0cm | 30.0cm | 30.0cm |
Package 2 Length | 40cm | 40.0cm | 40.0cm | 40.0cm |
Package 2 Weight | 8.255 kg | 11.306kg | 8.785 kg | 10.761kg |
Unit Type of Package 3 | P06 | PAL | PAL | PAL |
Number of Units in Package 3 | 120 | 336 | 384 | 336 |
Package 3 Height | 77cm | 60.0cm | 60.0cm | 60.0cm |
Package 3 Width | 80cm | 80.0cm | 80.0cm | 80.0cm |
Package 3 Length | 60cm | 75.0cm | 75.0cm | 75.0cm |
Package 3 Weight | 74.66 kg | 180.352kg | 140.627 kg | 178.895kg |
contract warranty | ||||
Warranty | 18 months | 18 months | 18 months | 18 months |