SITOP Smart – PSU100S – Siemens Power Supply

$ 407.00

SKU: 6EP1336-2BA10

Specifications

Part Number 6EP1336-2BA10
Input
type of the power supply network 1-phase AC
supply voltage at AC Automatic range selection
● initial value
supply voltage 120 V
● 1 at AC rated value
● 2 at AC rated value 230 V
input voltage 85 … 132 V
● 1 at AC
● 2 at AC 176 … 264 V
design of input wide range input No
overvoltage overload capability 2.3 × Vin rated, 1.3 ms
operating condition of the mains buffering at Vin = 120/230 V
buffering time for rated value of the output current in the event of power failure minimum 20 ms
operating condition of the mains buffering at Vin = 120/230 V
line frequency 50 Hz
● 1 rated value
● 2 rated value 60 Hz
line frequency 47 … 63 Hz
input current 7.5 A
● at rated input voltage 120 V
● at rated input voltage 230 V 3.5 A
current limitation of inrush current at 25 °C maximum 11:00 AM
I2t value maximum 10 A²·s
fuse protection type T 10 A (not accessible)
● in the feeder Recommended miniature circuit breaker: from 10 A characteristic C or circuit-breaker 3RV2411-1JA10 (120 V) or 3RV2411-1FA10 (230 V)
Output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage 24 V
● at output 1 at DC rated value
relative overall tolerance of the voltage 3%
relative control precision of the output voltage 0.50%
● on slow fluctuation of input voltage
● on slow fluctuation of ohm loading 1%
residual ripple 150 mV
● maximum
voltage peak 240 mV
● maximum
adjustable output voltage 24 … 28 V
product function output voltage adjustable Yes
type of output voltage setting via potentiometer; max. 480 W
 display version for normal operation Green LED for 24 V OK
 type of signal at output Relay contact (NO contact, rating 50 V DC/ 0.3 A) for “24 V OK”
 behavior of the output voltage when switching on No overshoot of Vout (soft start)
response delay maximum 1.5 s
 voltage increase time of the output voltage
●         typical 50 ms
●         maximum 500 ms
output current
●         rated value 20 A
●         rated rangesupplied active power typical short-term overload current 0 … 20 A; 24 A up to +45°C; +60 … +70 °C: Derating 5%/K
supplied active power typical 480 W
short-term overload current
●         on short-circuiting during the start-up typical 35 A
●         at short-circuit during operation typical 35 A
duration of overloading capability for excess current
●         on short-circuiting during the start-up typical 100 ms
●         at short-circuit during operation 100 ms
product feature
●         bridging of equipment Yes
number of parallel-switched equipment resources for increasing the power 2
Efficiency
efficiency in percent 90%
power loss [W] 53 W
● at rated output voltage for rated value of the output current typical
Closed-loop control
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical 1%
relative control precision of the output voltage load step of resistive load 50/100/50 % typical 3%
setting time 10 ms
● maximum
Protection and monitoring
design of the overvoltage protection Yes, according to EN 60950-1
response value current limitation typical 21 A
property of the output short-circuit proof Yes
design of short-circuit protection Electronic shutdown, automatic restart
enduring short circuit current RMS value 7:00 AM
● maximum
overcurrent overload capability in normal operation overload capability 150 % Iout rated up to 5 s/min
display version for overload and short circuit
Safety
galvanic isolation between input and output Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection class Class I
leakage current 3.5 mA
● maximum
● typical 1 mA
protection class IP IP20
Approvals
certificate of suitability Yes
● CE marking
● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259, cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
● cCSAus, Class 1, Division 2 No
● ATEX No
certificate of suitability No
● IECEx
● NEC Class 2 No
●         ULhazloc approval No
●         FM registration No
type of certification CB-certificate Yes
 certificate of suitability
●         EAC approval Yes
certificate of suitability shipbuilding approval Yes
 shipbuilding approval DNV GL
Marine classification association
●         American Bureau of Shipping Europe Ltd. (ABS) No
●         French marine classification society (BV) No
●         DNV GL Yes
●         Lloyds Register of Shipping (LRS) No
● Nippon Kaiji Kyokai (NK) No
EMC
standard EN 55022 Class B
● for emitted interference
● for mains harmonics limitation EN 61000-3-2
● for interference immunity EN 61000-6-2
environmental conditions
ambient temperature 0 … 70 °C; with natural convection
● during operation
● during transport -40 … +85 °C
● during storage -40 … +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 … 95% no condensation
Mechanics
type of electrical connection screw-type terminals
● at input L1, N, PE: 1 screw terminal each for 0.2 … 4 mm² single-core/finely stranded
● at output +, -: 2 screw terminals each for 0.2 … 4 mm²
● for auxiliary contacts 13, 14 (alarm signal): 1 screw terminal each for 0.14 … 1.5 mm²
width of the enclosure 115 mm
height of the enclosure 145 mm
depth of the enclosure 150 mm
required spacing 50 mm
● top
● bottom 50 mm
● left 0 mm
● right 0 mm
net weight 2.4 kg
product feature of the enclosure housing can be lined up Yes
fastening method Snaps onto DIN rail EN 60715 35×7.5/15
electrical accessories Buffer module
mechanical accessories Device identification label 20 mm × 7 mm, pale turquoise 3RT19001SB20
MTBF at 40 °C 1 778 916 h
other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)
Weight 2.4 kg
Dimensions 15.0 × 11.5 × 14.5 cm