$ 308.44 – $ 410.30
Article number | 6EP1336-3BA10 |
Product | SITOP PSU8200 |
Power supply, type | 24 V/20 A |
Input | |
type of the power supply network | 1-phase and 2-phase AC or DC |
supply voltage at AC | |
● minimum rated value | 120 V |
● maximum rated value | 230 V |
● initial value | 85 V; Derating of temperature necessary down to 50 °C at Vin < 100 V AC or DC |
● full-scale value | 275 V |
supply voltage | |
● 1 at AC rated value | |
● 2 at AC rated value | |
● at DC | 110 … 220 V |
input voltage | |
● 1 at AC | |
● 2 at AC | |
● at DC | 88 … 350 V |
design of input wide range input | Yes |
operating condition of the mains buffering | at Vin = 230 V |
buffering time for rated value of the output current in the event of power failure minimum | 20 ms |
operating condition of the mains buffering | at Vin = 230 V |
line frequency | |
● 1 rated value | 50 Hz |
● 2 rated value | 60 Hz |
line frequency | 45 … 65 Hz |
input current | |
● at rated input voltage 120 V | 4.6 A |
● at rated input voltage 230 V | 2.5 A |
current limitation of inrush current at 25 °C maximum | 20 A |
I2t value maximum | 5 A²·s |
fuse protection type | Yes |
● in the feeder | Recommended miniature circuit breaker at 1-phase operation: 10 A characteristic C; required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2711-1HD10 (UL 489) at 120 V or 3RV2711-1ED10 (UL 489) at 230 V |
Output | |
voltage curve at output | Controlled, isolated DC voltage |
output voltage at DC rated value | 24 V |
output voltage | |
● at output 1 at DC rated value | 24 V |
relative overall tolerance of the voltage | 3 % |
relative control precision of the output voltage | |
● on slow fluctuation of input voltage | 0.1 % |
● on slow fluctuation of ohm loading | 0.3 % |
residual ripple | |
● maximum | 100 mV |
● typical | 80 mV |
voltage peak | |
● maximum | 200 mV |
● typical | 100 mV |
adjustable output voltage | 24 … 28.8 V |
product function output voltage adjustable | Yes |
type of output voltage setting | via potentiometer |
display version for normal operation | Green LED for 24 V OK |
type of signal at output | Relay contact (NO contact, rating 60 V DC/ 0.3 A) for “24 V OK” |
behavior of the output voltage when switching on | No overshoot of Vout (soft start) |
response delay maximum | 1.5 s |
voltage increase time of the output voltage | |
● typical | 50 ms |
output current | |
● rated value | 20 A |
● rated range | 0 … 20 A; +60 … +70 °C: Derating 3%/K |
supplied active power typical | 480 W |
short-term overload current | |
● on short-circuiting during the start-up typical | |
● at short-circuit during operation typical | 60 A |
duration of overloading capability for excess current | |
● on short-circuiting during the start-up | |
● at short-circuit during operation | 25 ms |
constant overload current | |
● on short-circuiting during the start-up typical | 30 A |
product feature | |
● bridging of equipment | Yes; switchable characteristic |
number of parallel-switched equipment resources for increasing the power | 2 |
Efficiency | |
efficiency in percent | 93 % |
power loss [W] | |
● at rated output voltage for rated value of the output current typical | 42 W |
● during no-load operation maximum | |
Closed-loop control | |
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 0.5 % |
relative control precision of the output voltage load step of resistive load 50/100/50 % typical | 1 % |
setting time | |
● load step 50 to 100% typical | 1 ms |
● load step 100 to 50% typical | 1 ms |
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical | |
setting time | |
● load step 10 to 90% typical | |
● load step 90 to 10% typical | |
● maximum | 5 ms |
Protection and monitoring | |
design of the overvoltage protection | < 33 V |
● typical | 21.5 A |
property of the output short-circuit proof | Yes |
design of short-circuit protection | Alternatively, constant current characteristic approx. 23 A or latching shutdown |
enduring short circuit current RMS value | |
● typical | 23 A |
overcurrent overload capability in normal operation | overload capability 150 % Iout rated up to 5 s/min |
display version for overload and short circuit | LED yellow for “overload”, LED red for “latching shutdown” |
Safety | |
galvanic isolation between input and output | Yes |
galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
operating resource protection class | Class I |
leakage current | |
● maximum | 3.5 mA |
● typical | 1 mA |
protection class IP | IP20 |
Approvals | |
certificate of suitability | |
● CE marking | Yes |
● UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
● CSA approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
● cCSAus, Class 1, Division 2 | No |
● ATEX | No |
certificate of suitability | |
● IECEx | No |
● NEC Class 2 | No |
● ULhazloc approval | No |
● FM registration | No |
type of certification CB-certificate | Yes |
certificate of suitability | |
● EAC approval | Yes |
certificate of suitability shipbuilding approval | Yes |
shipbuilding approval | ABS, DNV GL |
Marine classification association | |
● American Bureau of Shipping Europe Ltd. (ABS) | Yes |
● French marine classification society (BV) | No |
● DNV GL | Yes |
● Lloyds Register of Shipping (LRS) | No |
● Nippon Kaiji Kyokai (NK) | No |
EMC | |
standard | |
● for emitted interference | EN 55022 Class B |
● for mains harmonics limitation | EN 61000-3-2 |
● for interference immunity | EN 61000-6-2 |
environmental conditions | |
ambient temperature | |
● during operation | -25 … +70 °C; With natural convection; startup tested starting from -40 °C nominal voltage |
● during transport | -40 … +85 °C |
● during storage | -40 … +85 °C |
environmental category according to IEC 60721 | Climate class 3K3, 5 … 95% no condensation |
Mechanics | |
type of electrical connection | screw-type terminals |
● at input | L, N, PE: 1 screw terminal each for 0.2 … 4 mm² single-core/finely stranded |
● at output | +, -: 2 screw terminals each for 0.2 … 4 mm² |
● for auxiliary contacts | 13, 14 (alarm signal): 1 screw terminal each for 0.14 … 1.5 mm² |
width of the enclosure | 90 mm |
height of the enclosure | 125 mm |
depth of the enclosure | 125 mm |
required spacing | |
● top | 50 mm |
● bottom | 50 mm |
● left | 0 mm |
● right | 0 mm |
net weight | 1.2 kg |
product feature of the enclosure housing can be lined up | Yes |
fastening method | Snaps onto DIN rail EN 60715 35×7.5/15 |
electrical accessories | Buffer module |
mechanical accessories | Device identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20 |
MTBF at 40 °C | 667 048 h |
other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
Article number | 6EP3334-8SB00-0AY0 |
Product | SITOP PSU8200 |
Input | |
type of the power supply network | 1-phase AC |
supply voltage at AC | |
● initial value | Automatic range selection |
supply voltage | |
● 1 at AC rated value | 120 V |
● 2 at AC rated value | 230 V |
input voltage | |
● 1 at AC | 85 … 132 V |
● 2 at AC | 170 … 264 V |
design of input wide range input | No |
operating condition of the mains buffering | at Vin = 120/230 V |
buffering time for rated value of the output current in the | 35 ms |
event of power failure minimum | |
operating condition of the mains buffering | at Vin = 120/230 V |
line frequency | |
● 1 rated value | 50 Hz |
● 2 rated value | 60 Hz |
line frequency | 47 … 63 Hz |
input current | |
● at rated input voltage 120 V | 4A |
● at rated input voltage 230 V | 1.9A |
current limitation of inrush current at 25 °C maximum | 10A |
I2t value maximum | 0.3 A²·s |
fuse protection type | T 6.3 A (not accessible) |
● in the feeder | Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V |
Output | |
voltage curve at output | Controlled, isolated DC voltage |
output voltage at DC rated value | 24v |
output voltage | |
● at output 1 at DC rated value | 24V |
relative overall tolerance of the voltage | 3% |
relative control precision of the output voltage | |
● on slow fluctuation of input voltage | 0.1% |
● on slow fluctuation of ohm loading | 0.3% |
residual ripple | |
● maximum | 50 mV |
voltage peak | |
● maximum | 200 mV |
adjustable output voltage | 24 … 28.8 V |
product function output voltage adjustable | Yes |
type of output voltage setting | via potentiometer; max. 240 W |
display version for normal operation | Green LED for 24 V OK |
type of signal at output | Relay contact (NO contact, rating 60 V DC/ 0.3 A) for “24 V OK” |
behavior of the output voltage when switching on | Overshoot of Vout approx. 3 % |
response delay maximum | 1.5 s |
voltage increase time of the output voltage | |
● typical | 70 ms |
output current | |
● rated value | 10A |
● rated range | 0 … 10 A; +60 … +70 °C: Derating 2%/K; as of Ua>24 V: 4% [Ia]/V [Ua]; at Ue<100 V/<200 V: 80% Ia rated |
supplied active power typical | 240 W |
short-term overload current | |
● at short-circuit during operation typical | 30 A |
duration of overloading capability for excess current | |
● at short-circuit during operation | 25 ms |
constant overload current | |
● on short-circuiting during the start-up typical product feature | 12 A |
● bridging of equipment | Yes; switchable characteristic |
number of parallel-switched equipment resources for increasing the power | 2 |
Efficiency | |
efficiency in percent | 94% |
power loss [W] | |
● at rated output voltage for rated value of the output current typical | 18 W |
● during no-load operation maximum | 1.5 W |
Closed-loop control | |
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical |
0.1% |
relative control precision of the output voltage load step of | 4% |
resistive load 50/100/50 % typical | |
setting time | |
● load step 50 to 100% typical | 0.25 ms |
● load step 100 to 50% typical | 0.5 ms |
relative control precision of the output voltage at load step | 4% |
of resistive load 10/90/10 % typical | |
setting time | |
● load step 10 to 90% typical | 0.25 ms |
● load step 90 to 10% typical | 0.5 ms |
● maximum | 1 ms |
Protection and monitoring | |
design of the overvoltage protection | < 33 V |
● typical | 12 A |
property of the output short-circuit proof | Yes |
design of short-circuit protection | Alternatively, constant current characteristic approx. 12 A or latching shutdown |
enduring short circuit current RMS value | |
● typical | 12 A |
overcurrent overload capability in normal operation | overload capability 150 % Iout rated up to 5 s/min |
display version for overload and short circuit | LED yellow for “overload”, LED red for “latching shutdown” |
Safety | |
galvanic isolation between input and output | Yes |
galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
operating resource protection class | Class I |
leakage current | |
● maximum | 3.4 mA |
● typical | 1 mA |
protection class IP | IP20 |
Approvals | |
certificate of suitability | |
● CE marking | Yes |
● UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
● CSA approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1) |
● cCSAus, Class 1, Division 2 | No |
● ATEX | No |
certificate of suitability | |
● IECEx | No |
● NEC Class 2 | No |
● ULhazloc approval | No |
● FM registration | No |
type of certification CB-certificate | Yes |
certificate of suitability | |
● EAC approval | Yes |
certificate of suitability shipbuilding approval | Yes |
shipbuilding approval | ABS, DNV GL |
Marine classification association | |
● American Bureau of Shipping Europe Ltd. (ABS) | Yes |
● French marine classification society (BV) | No |
● DNV GL | Yes |
● Lloyds Register of Shipping (LRS) | No |
● Nippon Kaiji Kyokai (NK) | No |
EMC | |
standard | |
● for emitted interference | EN 55022 Class B |
● for mains harmonics limitation | EN 61000-3-2 |
● for interference immunity | EN 61000-6-2 |
environmental conditions | |
ambient temperature | |
● during operation | -25 … +70 °C; With natural convection; startup tested starting from -40 °C nominal voltage |
● during transport | -40 … +85 °C |
● during storage | -40 … +85 °C |
environmental category according to IEC 60721 | Climate class 3K3, 5 … 95% no condensation |
Mechanics | |
type of electrical connection | screw-type terminals |
● at input | L, N, PE: 1 screw terminal each for 0.2 … 2.5 mm² single-core/finely stranded |
● at output | +, -: 2 screw terminals each for 0.2 … 2.5 mm² |
13, 14 (alarm signal): 1 screw terminal each for 0.14 … 1.5 mm²; 15, 16 (Remote): 1 screw terminal each for 0.14 … 1.5 mm² |
|
width of the enclosure | 55 mm |
height of the enclosure | 125 mm |
depth of the enclosure | 125 mm |
required spacing | |
● top | 50 mm |
● bottom | 50 mm |
● left | 0 mm |
● right | 0 mm |
net weight | 1kg |
product feature of the enclosure housing can be lined up | Yes |
fastening method | Snaps onto DIN rail EN 60715 35×7.5/15 |
electrical accessories | Buffer module |
mechanical accessories | Device identification label 20 mm × 7 mm, TI-grey 3RT2900-1SB20 |
MTBF at 40 °C | 1 292 102 h |
other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
Weight | N/A |
---|---|
Dimensions | N/A |
Model |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)