$ 95.48 – $ 124.74
Part number | 3RV5031-4DA10 | 3RV5031-4EA10 | 3RV5031-4FA10 | 3RV5031-4GA10 | 3RV5031-4HA10 |
product brand name | SIRIUS | SIRIUS | SIRIUS | SIRIUS | SIRIUS |
product designation | Circuit breaker | Circuit breaker | Circuit breaker | Circuit breaker | Circuit breaker |
design of the product | for motor protection | for motor protection | for motor protection | for motor protection | for motor protection |
product type designation | 3RV5 | 3RV5 | 3RV5 | 3RV5 | 3RV5 |
General technical data | |||||
size of the circuit-breaker | S2 | S2 | S2 | S2 | S2 |
power loss [W] total typical | 12 W | 15 W | 20 W | 20 W | 20 W |
insulation voltage with degree of pollution 3 at AC rated value | 690 V | 690 V | 690 V | 690 V | 690 V |
surge voltage resistance rated value | 6 kV | 6 kV | 6 kV | 6 kV | 6 kV |
shock resistance according to IEC 60068-2-27 | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms | 25g / 11 ms |
Substance Prohibitance (Date) | 7/1/2006 | 7/1/2006 | 7/1/2006 | 7/1/2006 | 7/1/2006 |
Ambient conditions | |||||
installation altitude at height above sea level maximum | 2 000 m | 2 000 m | 2 000 m | 2 000 m | 2 000 m |
ambient temperature | |||||
? during operation | -20 … +60 °C | -20 … +60 °C | -20 … +60 °C | -20 … +60 °C | -20 … +60 °C |
? during transport | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C | -50 … +80 °C |
relative humidity during operation | 10 … 95 % | 10 … 95 % | 10 … 95 % | 10 … 95 % | 10 … 95 % |
Main circuit | |||||
number of poles for main current circuit | 3 | 3 | 3 | 3 | 3 |
adjustable current response value current of the current-dependent overload release | 18 … 25 A | 22 … 32 A | 28 … 40 A | 36 … 45 A | 40 … 50 A |
operating voltage | |||||
rated value | 690 V | 690 V | 690 V | 690 V | 690 V |
at AC-3 rated value maximum | 690 V | 690 V | 690 V | 690 V | 690 V |
operating frequency rated value | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz | 50 … 60 Hz |
operational current rated value 25 A | 25 A | 32 A | 40 A | 45 A | 50 A |
operational current at AC-3 at 400 V rated value | 25 A | 32 A | 40 A | 45 A | 50 A |
operating frequency at AC-3 maximum | 15 1/h | 15 1/h | 15 1/h | 15 1/h | 15 1/h |
Protective and monitoring functions | |||||
trip class | CLASS 10 | CLASS 10 | CLASS 10 | CLASS 10 | CLASS 10 |
design of the overload release | thermal | thermal | thermal | thermal | thermal |
maximum short-circuit current breaking capacity (Icu) at AC at 400 V rated value | 50 kA | 50 kA | 50 kA | 50 kA | 50 kA |
operating short-circuit current breaking capacity (Ics) at AC at 400 V rated value | 25 kA | 25 kA | 25 kA | 25 kA | 25 kA |
response value current of instantaneous short-circuit trip unit | 325 A | 416 A | 520 A | 585 A | 650 A |
Short-circuit protection | |||||
product function short circuit protection | Yes | Yes | Yes | Yes | Yes |
design of the short-circuit trip | magnetic | magnetic | magnetic | magnetic | magnetic |
Installation/ mounting/ dimensions | |||||
mounting position | any | any | any | any | any |
fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN50022 |
height | 140 mm | 140 mm | 140 mm | 140 mm | 140 mm |
width | 55 mm | 55 mm | 55 mm | 55 mm | 55 mm |
depth | 149 mm | 149 mm | 149 mm | 149 mm | 149 mm |
required spacing for grounded parts | |||||
forwards | 140 mm | 140 mm | 140 mm | 140 mm | 140 mm |
backwards | 0 mm | 0 mm | 0 mm | 0 mm | 0 mm |
upwards | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm |
at the side | 30 mm | 30 mm | 30 mm | 30 mm | 30 mm |
downwards | 50 mm | 50 mm | 50 mm | 50 mm | 50 mm |
Connections/ Terminals | |||||
type of electrical connection | |||||
for main current circuit | screw-type terminals with box terminals | screw-type terminals with box terminals | screw-type terminals with box terminals | screw-type terminals with box terminals | screw-type terminals with box terminals |
arrangement of electrical connectors for main current circuit | Top and bottom | Top and bottom | Top and bottom | Top and bottom | Top and bottom |
type of connectable conductor cross-sections | |||||
for main contacts | |||||
— solid or stranded | 2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) | 2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) | 2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) | 2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) | 2x (0.75 … 25 mm²), 1x (0.75 … 35 mm²) |
— finely stranded with core end processing | 2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) | 2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) | 2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) | 2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) | 2x (0.75 … 16 mm²), 1x (0.75 … 25 mm²) |
at AWG cables for main contacts | 2x (18 … 2), 1x (18 … 2) | 2x (18 … 2), 1x (18 … 2) | 2x (18 … 2), 1x (18 … 2) | 2x (18 … 2), 1x (18 … 2) | 2x (18 … 2), 1x (18 … 2) |
tightening torque | |||||
for main contacts with screw-type terminals | 3 … 4.5 N·m | 3 … 4.5 N·m | 3 … 4.5 N·m | 3 … 4.5 N·m | 3 … 4.5 N·m |
Safety related data | |||||
protection class IP on the front according to IEC 60529 | IP20 | IP20 | IP20 | IP20 | IP20 |
touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front | finger-safe, for vertical contact from the front |
Weight | N/A |
---|---|
Dimensions | N/A |