SIRIUS 3RV2 – Motor Starter Protectors – Siemens Motor Starter Protectors

USD $ 86.94

SKU: N/A

Siemens 3RV2 Motor Starter Protectors Product Specifications:

Part Number 3RV2011-1JA10 3RV2011-1HA20
product brand name SIRIUS SIRIUS
product designation Circuit breaker Circuit breaker
design of the product For motor protection For motor protection
product type designation 3RV2 3RV2
General technical data
size of the circuit-breaker S00 S00
size of contactor can be combined company-specific S00,S0 S00,S0
product extension auxiliary switch Yes Yes
power loss [W] for rated value of the current
● at AC in hot operating state 9.25 W 9.25 W 9.25 W
● at AC in hot operating state per pole 3.1 W 3.1W 3.1W
insulation voltage with degree of pollution 3 at AC rated value 690 V 690 V
surge voltage resistance rated value 6 kV 6 kV 6 kV
shock resistance according to IEC 60068-2-27 25g / 11 ms 25g / 11 ms
mechanical service life (operating cycles)
● of the main contacts typical 100 000 100 000
● of auxiliary contacts typical 100 000 100 000
electrical endurance (operating cycles) typical 100 000 100 000
type of protection according to ATEX directive
2014/34/EU
Ex II (2) GD Ex II (2) GD
certificate of suitability according to ATEX directive
2014/34/EU
DMT 02 ATEX F 001 DMT 02 ATEX F 001
reference code according to IEC 81346-2 Q Q
Substance Prohibitance (Date) 10/01/2009 10/1/2009 10/1/2009
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
● during operation  -20 … +60 °C  -20 … +60 °C
● during storage  -50 … +80 °C  -50 … +80 °C
● during transport  -50 … +80 °C  -50 … +80 °C
relative humidity during operation  10 … 95 %  10 … 95 %
Main circuit
number of poles for main current circuit 3 3
adjustable current response value current of the
current-dependent overload release
7 … 10 A 5.5 … 8 A
operating voltage
● rated value 20 … 690 V 20 … 690 V
● at AC-3 rated value maximum 690 V 690 V
● at AC-3e rated value maximum 690 V 690 V
operating frequency rated value 50 … 60 Hz 50 … 60 Hz
operational current rated value 10 A 8 A
operational current
● at AC-3 at 400 V rated value 10 A 8 A
● at AC-3e at 400 V rated value 10 A 8 A
operating power
● at AC-3
— at 230 V rated value 2.2 kW 1.5 kW
— at 400 V rated value 4 kW 3 kW
— at 500 V rated value 5.5 kW 4 kW
— at 690 V rated value 7.5 kW 5.5 kW
● at AC-3e
— at 230 V rated value 2.2 kW 1.5 kW
— at 400 V rated value 4 kW 3 kW
— at 500 V rated value 5.5 kW 4 kW
— at 690 V rated value 7.5 kW 5.5 kW
operating frequency
● at AC-3 maximum 15 1/h 15 1/h
● at AC-3e maximum 15 1/h 15 1/h
Auxiliary circuit
number of NC contacts for auxiliary contacts 0
number of NO contacts for auxiliary contacts 0 0
number of CO contacts for auxiliary contacts 0 0
product function
● ground fault detection No No No
● phase failure detection Yes Yes Yes
trip class CLASS 10 CLASS 10
design of the overload release thermal thermal
maximum short-circuit current breaking capacity (Icu)
● at AC at 240 V rated value 100 kA 100 kA
● at AC at 400 V rated value 100 kA 100 kA 100 kA
● at AC at 500 V rated value 42 kA 42 kA 42 kA
● at AC at 690 V rated value 6 kA 6 kA 6 kA
operating short-circuit current breaking capacity (Ics)
at AC
● at 240 V rated value 100 kA 100 kA 100 kA
● at 400 V rated value 100 kA 100 kA 100 kA
● at 500 V rated value 42 kA 42 kA 42 kA
● at 690 V rated value 4 kA 4 kA 6 kA
response value current of instantaneous short-circuit trip
unit
130 A 104 A
UL/CSA ratings
full-load current (FLA) for 3-phase AC motor
● at 480 V rated value 10 A 10 A 8 A
● at 600 V rated value 10 A 10 A 8 A
yielded mechanical performance [hp]
● for single-phase AC motor
— at 110/120 V rated value 0.5 hp 0.33 hp
— at 230 V rated value 1.5 hp 1 hp
● for 3-phase AC motor
— at 200/208 V rated value 2 hp 2 hp
— at 220/230 V rated value 3 hp 2 hp
— at 460/480 V rated value 5 hp 5 hp
— at 575/600 V rated value 10 hp 5 hp
Short-circuit protection
product function short circuit protection Yes Yes
design of the short-circuit trip magnetic magnetic
design of the fuse link for IT network for short-circuit
protection of the main circuit
● at 400 V gL/gG 50 A gL/gG 50 A
● at 500 V gL/gG 40 A gL/gG 40 A
● at 690 V gL/gG 40 A gL/gG 35 A
Installation/ mounting/ dimensions
mounting position any any
fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN
60715
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN
60715
height 97 mm 106 mm
width 45 mm 45 mm
depth 97 mm 97 mm
required spacing
● with side-by-side mounting at the side 0 mm 0 mm
● for grounded parts at 400 V
— downwards 30 mm 30 mm
— upwards 30 mm 30 mm
— at the side 9 mm 9 mm
● for live parts at 400 V
— downwards 30 mm 30 mm
— upwards 30 mm 30 mm
— at the side 9 mm 9 mm
● for live parts at 500 V
— downwards 30 mm 30 mm
— upwards 30 mm 30 mm
— at the side 9 mm 9 mm
● for grounded parts at 690 V
— downwards 50 mm 50 mm
— upwards 50 mm 50 mm
— backwards 0 mm 0 mm
— at the side 30 mm 30 mm
— forwards 0 mm 0 mm
● for live parts at 690 V
— downwards 50 mm 50 mm
— upwards 50 mm 50 mm
— backwards 0 mm 0 mm
— at the side 30 mm 30 mm
— forwards 0 mm 0 mm
Connections/ Terminals
type of electrical connection
● for main current circuit screw-type terminals spring-loaded terminals
arrangement of electrical connectors for main current circuit Top and bottom Top and bottom
type of connectable conductor cross-sections
● for main contacts
— solid or stranded 2x (0,75 … 2,5 mm²), 2x 4 mm² 2x (0,5 … 4 mm²)
— finely stranded with core end processing 2x (0.5 … 1.5 mm²) 2x (0.5 … 2.5 mm²)
— finely stranded without core end processing 2x (0.75 … 2.5 mm²) 2x (0.5 … 2.5 mm²)
● at AWG cables for main contacts 2x (18 … 14), 2x 12 2x (20 … 12)
tightening torque
● for main contacts with screw-type terminals 0.8 … 1.2 N·m N/A
design of screwdriver shaft Diameter 5 to 6 mm Diameter 3 mm
size of the screwdriver tip Pozidriv size 2 3,0 x 0,5 mm
design of the thread of the connection screw
● for main contacts M3 N/A
Safety related data
B10 value
● with high demand rate according to SN 31920 5000 5000
proportion of dangerous failures
● with low demand rate according to SN 31920 50% 50%
● with high demand rate according to SN 31920 50% 50%
failure rate [FIT]
● with low demand rate according to SN 31920 50 FIT 51 FIT
T1 value for proof test interval or service life according to
IEC 61508
10 a 10 a
protection class IP on the front according to IEC
60529
IP20 IP20
touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front finger-safe, for vertical contact from the front
display version for switching status Handle Handle
Weight N/A
Dimensions N/A