| product name | 3RT2024-1AG24 |
| product brand name | SIRIUS |
| product designation | Power contactor |
| product type designation | 3RT2 |
| General technical data | |
| size of contactor | S0 |
| product extension | No |
| ● function module for communication | |
| ● auxiliary switch | No |
| power loss [W] for rated value of the current | 0.9 W |
| ● at AC in hot operating state | |
| ● at AC in hot operating state per pole | 0.3 W |
| ● without load current share typical | 7.9 W |
| insulation voltage | 690 V |
| ● of main circuit with degree of pollution 3 rated value | |
| ● of auxiliary circuit with degree of pollution 3 rated value | 690 V |
| surge voltage resistance | 6 kV |
| ● of main circuit rated value | |
| ● of auxiliary circuit rated value | 6 kV |
| maximum permissible voltage for safe isolation between coil and main contacts according to EN 60947-1 | 400 V |
| shock resistance at rectangular impulse | 7,5g / 5 ms, 4,7g / 10 ms |
| ● at AC | |
| shock resistance with sine pulse | 11,8g / 5 ms, 7,4g / 10 ms |
| ● at AC | |
| mechanical service life (operating cycles) | 10 000 000 |
| ● of contactor typical | |
| ● of the contactor with added electronically optimized auxiliary switch block typical | 5 000 000 |
| ● of the contactor with added auxiliary switch block typical | 10 000 000 |
| reference code according to IEC 81346-2 | Q |
| Substance Prohibitance (Date) | 10/1/2009 |
| Ambient conditions | |
| installation altitude at height above sea level maximum | 2 000 m |
| ambient temperature | -25 … +60 °C |
| ● during operation | |
| ● during storage | -55 … +80 °C |
| relative humidity minimum | 10% |
| relative humidity at 55 °C according to IEC 60068-2-30 maximum | 95% |
| Main circuit | |
| number of poles for main current circuit | 3 |
| number of NO contacts for main contacts | 3 |
| operating voltage | |
| ? at AC-3 rated value maximum | 690 V |
| ? at AC-3e rated value maximum | 690 V |
| operational current | |
| ? at AC-1 at 400 V at ambient temperature 40 °C rated value | 40 A |
| ? at AC-1 | |
| — up to 690 V at ambient temperature 40 °C rated value | 40 A |
| — up to 690 V at ambient temperature 60 °C rated value | 35 A |
| ? at AC-3 | |
| — at 400 V rated value | 12A |
| — at 500 V rated value | 12A |
| — at 690 V rated value | 9A |
| ? at AC-3e | |
| — at 400 V rated value | 12A |
| — at 500 V rated value 12A | 12A |
| — at 690 V rated value 9A | 9A |
| ? at AC-4 at 400 V rated value | 12.5 A |
| ? at AC-5a up to 690 V rated value x | 12.5 A |
| ? at AC-5b up to 400 V rated value | 9.9 A |
| ? at AC-6a | |
| — up to 230 V for current peak value n=20 rated value | 11.4 A |
| — up to 400 V for current peak value n=20 rated value | 11.4 A |
| — up to 500 V for current peak value n=20 rated value | 11.3 A |
| — up to 690 V for current peak value n=20 rated value | 9A |
| ? at AC-6a | 2.9 A |
| — up to 230 V for current peak value n=30 rated value | 7.6 A |
| — up to 400 V for current peak value n=30 rated value | 7.6 A |
| — up to 500 V for current peak value n=30 rated value | 7.6 A |
| — up to 690 V for current peak value n=30 rated value | 7.6 A |
| minimum cross-section in main circuit at maximum AC-1 rated value | 10 mm² |
| operational current for approx. 200000 operating | |
| cycles at AC-4 | |
| ? at 400 V rated value | 5.5 A |
| ? at 690 V rated value | 5.5 A |
| operational current | |
| ? at 1 current path at DC-1 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 4.5 A |
| — at 220 V rated value | 1A |
| — at 440 V rated value | 0.4 A |
| — at 600 V rated value | 0.25 A |
| ? with 2 current paths in series at DC-1 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 35 A |
| — at 220 V rated value | 5A |
| — at 440 V rated value | 1A |
| — at 600 V rated value | 0.8 A |
| ? with 3 current paths in series at DC-1 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 35 A |
| — at 220 V rated value | 35 A |
| — at 440 V rated value | 2.9 A |
| — at 600 V rated value | 1.4 A |
| ? at 1 current path at DC-3 at DC-5 | |
| — at 24 V rated value | 20 A |
| — at 220 V rated value | 1A |
| — at 440 V rated value | 0.09 A |
| — at 600 V rated value | 0.06 A |
| ? with 2 current paths in series at DC-3 at DC-5 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 15 A |
| — at 220 V rated value | 3A |
| — at 440 V rated value | 0.27 A |
| — at 600 V rated value | 0.16 A |
| ? with 3 current paths in series at DC-3 at DC-5 | |
| — at 24 V rated value | 35 A |
| — at 110 V rated value | 35 A |
| — at 220 V rated value | 10A |
| — at 440 V rated value | 0.6 A |
| — at 600 V rated value | 0.6 A |
| operating power | |
| ? at AC-3 | |
| — at 230 V rated value | 3 kW |
| — at 400 V rated value | 5.5 kW |
| — at 500 V rated value 5.5 kW | 5.5 kW |
| — at 690 V rated value | 7.5 kW |
| ? at AC-3e | |
| — at 230 V rated value | 3 kW |
| — at 400 V rated value | 5.5 kW |
| — at 500 V rated value | 5.5 kW |
| — at 690 V rated value | 7.5 kW |
| operating power for approx. 200000 operating cycles at AC-4 | |
| ? at 400 V rated value | 2.6 kW |
| ? at 690 V rated value | 4.6 kW |
| operating apparent power at AC-6a | |
| ? up to 230 V for current peak value n=20 rated value | 4.5 kVA |
| ? up to 400 V for current peak value n=20 rated value | 7.8 kVA |
| ? up to 500 V for current peak value n=20 rated value | 9.8 kVA |
| ? up to 690 V for current peak value n=20 rated value | 10.7 kVA |
| operating apparent power at AC-6a | |
| ? up to 230 V for current peak value n=30 rated value | 3 kVA |
| ? up to 400 V for current peak value n=30 rated value | 5.2 kVA |
| ? up to 500 V for current peak value n=30 rated value | 6.5 kVA |
| ? up to 690 V for current peak value n=30 rated value | 9 kVA |
| short-time withstand current in cold operating state | |
| up to 40 °C | |
| ? limited to 1 s switching at zero current maximum | 210 A; Use minimum cross-section acc. to AC-1 rated value |
| ? limited to 5 s switching at zero current maximum | 210 A; Use minimum cross-section acc. to AC-1 rated value |
| ? limited to 10 s switching at zero current maximum | 170 A; Use minimum cross-section acc. to AC-1 rated value |
| ? limited to 30 s switching at zero current maximum | 126 A; Use minimum cross-section acc. to AC-1 rated value |
| ? limited to 60 s switching at zero current maximum | 105 A; Use minimum cross-section acc. to AC-1 rated value |
| no-load switching frequency | |
| ? at AC | 5 000 1/h |
| operating frequency | |
| ? at AC-1 maximum | 1 000 1/h |
| ? at AC-2 maximum | 1 000 1/h |
| ? at AC-3 maximum | 1 000 1/h |
| ? at AC-3e maximum | 1 000 1/h |
| ? at AC-4 maximum | 300 1/h |
| Control circuit/ Control | |
| type of voltage of the control supply voltage | AC |
| control supply voltage at AC | |
| ? at 50 Hz rated value | 110 V |
| ? at 60 Hz rated value | 110 V |
| operating range factor control supply voltage rated | |
| value of magnet coil at AC | |
| ? at 50 Hz | 0.8 … 1.1 |
| ? at 60 Hz | 0.85 … 1.1 |
| apparent pick-up power of magnet coil at AC | |
| ? at 50 Hz | 68 VA |
| ? at 60 Hz | 67 VA |
| inductive power factor with closing power of the coil | |
| ? at 50 Hz | 0.72 |
| ? at 60 Hz | 0.74 |
| apparent holding power of magnet coil at AC | |
| ? at 50 Hz | 7.9 VA |
| ? at 60 Hz | 6.5 VA |
| inductive power factor with the holding power of the coil | |
| ? at 50 Hz | 0.25 |
| ? at 60 Hz | 0.28 |
| closing delay | |
| ? at AC | 8 … 40 ms |
| opening delay | |
| ? at AC | 4 … 16 ms |
| arcing time | 10 … 10 ms |
| control version of the switch operating mechanism | Standard A1 – A2 |
| Auxiliary circuit | |
| number of NC contacts for auxiliary contacts instantaneous contact | 2 |
| number of NO contacts for auxiliary contacts instantaneous contact | 2 |
| operational current at AC-12 maximum | 10:00 AM |
| operational current at AC-15 | 6:00 AM |
| ● at 230 V rated value | |
| ● at 400 V rated value | 3:00 AM |
| ● at 500 V rated value | 2:00 AM |
| ● at 690 V rated value | 1:00 AM |
| operational current at DC-12 | 10:00 AM |
| ● at 24 V rated value | |
| ● at 48 V rated value | 6:00 AM |
| ● at 60 V rated value | 6:00 AM |
| ● at 110 V rated value | 3:00 AM |
| ● at 125 V rated value | 2:00 AM |
| ● at 220 V rated value | 1:00 AM |
| ● at 600 V rated value | 0.15 A |
| operational current at DC-13 | 6:00 AM |
| ● at 24 V rated value | |
| ● at 48 V rated value | 2:00 AM |
| ● at 60 V rated value | 2:00 AM |
| ● at 110 V rated value | 1:00 AM |
| ● at 125 V rated value | 0.9 A |
| ● at 220 V rated value | 0.3 A |
| ● at 600 V rated value | 0.1 A |
| contact reliability of auxiliary contacts | 1 faulty switching per 100 million (17 V, 1 mA) |
| UL/CSA ratings | |
| full-load current (FLA) for 3-phase AC motor | 11:00 AM |
| ● at 480 V rated value | |
| ● at 600 V rated value | 11:00 AM |
| yielded mechanical performance [hp] ● for single-phase AC motor | 1 hp |
| — at 110/120 V rated value | |
| — at 230 V rated value | 2 hp |
| ● for 3-phase AC motor | 3 hp |
| — at 200/208 V rated value | |
| — at 220/230 V rated value | 3 hp |
| — at 460/480 V rated value | 7.5 hp |
| — at 575/600 V rated value | 10 hp |
| contact rating of auxiliary contacts according to UL | A600 / Q600 |
| Short-circuit protection | |
| design of the fuse link | gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA) |
| ● for short-circuit protection of the main circuit | |
| — with type of coordination 1 required | |
| — with type of assignment 2 required | gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA) |
| ● for short-circuit protection of the auxiliary switch required | gG: 10 A (500 V, 1 kA) |
| Installation/ mounting/ dimensions | |
| mounting position | +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
| fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 |
| ● side-by-side mounting | Yes |
| height | 85 mm |
| width | 45 mm |
| depth | 141 mm |
| required spacing | 10 mm |
| ● with side-by-side mounting | |
| — forwards | |
| — upwards | 10 mm |
| — downwards | 10 mm |
| — at the side | 0 mm |
| ● for grounded parts | 10 mm |
| — forwards | |
| — upwards | 10 mm |
| — at the side | 6 mm |
| — downwards | 10 mm |
| ● for live parts — forwards | 10 mm |
| — upwards | 10 mm |
| — downwards | 10 mm |
| — at the side | 6 mm |
| Connections/ Terminals | |
| type of electrical connection | screw-type terminals |
| ● for main current circuit | |
| ● for auxiliary and control circuit | screw-type terminals |
| ● at contactor for auxiliary contacts | Screw-type terminals |
| ● of magnet coil | Screw-type terminals |
| type of connectable conductor cross-sections ● for main contacts | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
| — solid | |
| — solid or stranded | 2x (1 … 2.5 mm²), 2x (2.5 … 10 mm²) |
| — finely stranded with core end processing | 2x (1 … 2.5 mm²), 2x (2.5 … 6 mm²), 1x 10 mm² |
| ● at AWG cables for main contacts | 2x (16 … 12), 2x (14 … 8) |
| connectable conductor cross-section for main contacts | 1 … 10 mm² |
| ● solid | |
| ● stranded | 1 … 10 mm² |
| ● finely stranded with core end processing | 1 … 10 mm² |
| connectable conductor cross-section for auxiliary contacts | 0.5 … 2.5 mm² |
| ● solid or stranded | |
| ● finely stranded with core end processing | 0.5 … 2.5 mm² |
| type of connectable conductor cross-sections ● for auxiliary contacts | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
| — solid or stranded | |
| — finely stranded with core end processing | 2x (0.5 … 1.5 mm²), 2x (0.75 … 2.5 mm²) |
| ● at AWG cables for auxiliary contacts | 2x (20 … 16), 2x (18 … 14) |
| AWG number as coded connectable conductor cross section | 16 … 8 |
| ● for main contacts | |
| ● for auxiliary contacts | 20 … 14 |
| Safety related data | |
| product function | |
| ● mirror contact according to IEC 60947-4-1 | Yes No |
| ● positively driven operation according to IEC 60947-5-1 | 450 000 |
| B10 value with high demand rate according to SN 31920 proportion of dangerous failures | 40% |
| ● with low demand rate according to SN 31920 | 73% |
| ● with high demand rate according to SN 31920failure rate [FIT] with low demand rate according to SN 31920 | 100 FIT |
| T1 value for proof test interval or service life according to IEC 61508 protection class IP on the front according to IEC | 20 a IP20 |
| 60529 touch protection on the front according to IEC 60529 suitability for use | finger-safe, for vertical contact from the front |
| ● safety-related switching OFF | Yes |