$ 200.10 – $ 498.41Price range: $ 200.10 through $ 498.41
Today, in an increasing number of applications in plant and machinery construction, individual automation and drive solutions are demanded that automate simple motion sequences with low associated requirements.
The compact SINAMICSÂ V20, the basic performance converter, offers a simple and cost-effective drive solution for these types of applications. SINAMICSÂ V20 sets itself apart with its quick commissioning times, ease of operation, robustness and cost-efficiency.
With nine frame sizes, it covers a power range extending from 0.12Â kW to 30Â kW (0.16Â hp to 40Â hp).
SINAMICS V20 keeps engineering and commissioning costs as well as those in operation as low as possible. To increase energy efficiency, the converter is equipped with a control technique to achieve optimum energy efficiency through automatic flux reduction. Not only this, it displays the actual energy consumption and has additional, integrated energy-saving functions. This allows energy consumption to be slashed drastically.
| SINAMICSÂ V20 | |
| Article Number |
|
| Power range | 230Â VÂ 1Â AC: 0.12Â …Â 3Â kW (0.16Â …Â 4Â hp) |
| 400Â V 3Â AC: Â 0.37Â …Â 30Â kW (0.5Â …Â 40Â hp) | |
| Offset factor cos φ | ≥0.95 |
| Power factor λ | 0.72 |
| Line voltage | 230Â VÂ 1Â AC: 200Â …Â 240Â VÂ 1Â AC (-15Â …Â +10Â %)Â 1) |
| 400Â VÂ 3Â AC: 380Â …Â 480Â VÂ 3Â ACÂ (-15Â …Â +10Â %) | |
| Maximum output voltage | 100Â % of input voltage |
| Line frequency | 50Â Hz/60Â Hz |
| Line system configuration | TN, TT, TT grounded line supply |
| IT for | |
| 230Â VÂ 1Â AC unfiltered devices, frame sizes FSAA, FSAB, FSAC, and FSAD | |
| 400Â VÂ 3Â AC unfiltered devices | |
| Overload capability | |
| Up to 15Â kW | High overload (HO): |
| 150Â %Â IHÂ for 60Â s within a cycle time of 300Â s. | |
| From 18.5Â kW | Low overload (LO): |
| 110Â %Â ILÂ for 60Â s within a cycle time of 300Â s. | |
| High overload (HO): | |
| 150Â %Â IHÂ for 60Â s within a cycle time of 300Â s. | |
| Output frequency | 0Â …Â 550Â Hz, resolution: 0.01Â Hz |
| Pulse frequency | 2Â …Â 16Â kHz |
| Efficiency | 95Â …Â 98Â % |
| According to IECÂ 61800-9-2 | |
| Efficiency class | IE2 |
| According to IECÂ 61800-9-2 | |
| Programmable fixed frequency setpoints | 16 |
| Analog inputs | AI1: bipolar current/voltage mode |
| AI2: unipolar current/voltage mode | |
| can be used as digital inputs | |
| Resolution | 12Â bit |
| Analog output | AO1 current output |
| 0 … 20 mA | |
| Digital inputs | DI1Â …Â DI4: isolated; for 400Â V converters with optional SINAMICSÂ V20 I/OÂ Extension Module two additional digital inputs DI5 and DI6 |
| PNP/NPN selectable via terminal | |
| Input current, max. | 15Â mA |
| Digital outputs | DO1: transistor output |
| DO2: relay output; for 400Â V converters with optional SINAMICSÂ V20 I/OÂ Extension Module two additional digital outputs (relay outputs) DO3 and DO4 | |
| 250Â VÂ AC 0.5Â A with resistive load | |
| 30Â VÂ DC 0.5Â A with resistive load | |
| Integrated interface | |
| Type | RS485 |
| Protocols | USS, Modbus RTU |
| Extension interface | SINAMICSÂ V20 BOP Interface, SINAMICSÂ V20 Smart Access, SINAMICSÂ V20Â Parameter Loader, SINAMICSÂ V20 I/OÂ Extension Module (cannot be operated simultaneously with SINAMICSÂ V20 Parameter Loader) |
| Control methods | |
| V/f linear/square/multi-point | ✓ |
| V/f with flux current control (FCC) | ✓ |
| Functions | |
| Easy to use | |
| Automatic restart | ✓ |
| Parameter cloning | ✓ |
| Drive data sets (DDS) | ✓ (3) |
| Command data sets (CDS) | ✓ (3) |
| JOG | ✓ |
| Pre-configured connection macros and application macros | ✓ |
| Simple parameter-based menu on internal or external SINAMICS V20 BOP | ✓ |
| Simple text menu for setup | ✓ |
| USS | ✓ |
| Modbus RTU | ✓ |
| Motor frequency display scaling | ✓ |
| Customization of parameter defaults | ✓ |
| Energy consumption monitoring | ✓ |
| List of modified parameters | ✓ |
| Converter status in case of a fault | ✓ |
| Application | |
| Keep Running Mode | ✓ |
| Flying restart | ✓ |
| PID controller | ✓ |
| Kinetic buffering (Vdc_min controller) | ✓ |
| Skippable frequency bandwidth | 4 |
| Braking functions | |
| DC braking | ✓ |
| Compound braking | ✓ |
| Dynamic braking | ✓ |
| 2-wire/3-wire control | ✓ |
| Mechanical holding brake control | ✓ |
| Super torque mode | ✓ |
| Hammer start mode | ✓ |
| Blockage clearing mode | ✓ |
| Hibernation mode | ✓ |
| Motor staging | ✓ |
| Multi-pump control 2) | ✓ |
| (for 400Â V converters with optional SINAMICSÂ V20 I/OÂ Extension Module) | |
| Dual ramp parameterizable | ✓ |
| Wobble function | ✓ |
| BICO function | ✓ |
| Slip compensation | ✓ |
| Protection | |
| DC link voltage control | ✓ |
| Load torque monitoring | ✓ |
| Phase loss detection | ✓ |
| Cavitation protection | ✓ |
| Condensation protection | ✓ |
| Frost protection | ✓ |
| Control | |
| ECO mode | ✓ |
| Vdc_max controller | ✓ |
| Imax controller | ✓ |
| Programmable V/f coordinates | ✓ |
| Flexible voltage boost | ✓ |
| 50/60 Hz adaptation | ✓ |
| 1)Â Single-phase devices can also be connected to two phases of a 3-phase 230 V power supply system. You can find more information here: | |
| General technical specifications | ||||||||||
| Degree of protection | IP20 | |||||||||
| Mounting | Wall mounting, side-by-side mounting, push-through mounting for FSB, FSC, FSD, and FSE | |||||||||
| Ambient temperature | ||||||||||
| Operation | -10 … +40 °C (14 … 104 °F) without derating | |||||||||
| 40 … 60 °C (104 … 140 °F) with derating | ||||||||||
| Storage | -40 … +70 °C (-40 … +158 °F) | |||||||||
| Relative humidity | 95Â % (non-condensing) | |||||||||
| Cooling | ||||||||||
| FSAA, FSAB, FSA up to 0.75Â kW | Convection cooling | |||||||||
| FSAC, FSAD, FSA, FSB, FSC, FSD, FSE | Power electronics cooled using heat sinks with external fan | |||||||||
| Installation altitude | Up to 4000Â m (13124Â ft) above sea level | |||||||||
| 1000 … 4000Â m: (3281 … 13124Â ft): output current derating | ||||||||||
| 2000 … 4000Â m (6562 … 13124Â ft): input voltage derating | ||||||||||
| Motor cable length | ||||||||||
| Unshielded | ||||||||||
| FSAA to FSD | 50Â m (164Â ft) | |||||||||
| FSE | 100Â m (328 ft) | |||||||||
| Shielded | ||||||||||
| FSAA to FSD | 25Â m (82Â ft) | |||||||||
| FSE | 50Â m (164Â ft) | |||||||||
| Longer motor cables with an additional output reactor | ||||||||||
| 230Â VÂ 1Â AC | 200Â m (656Â ft) (shielded and unshielded) | |||||||||
| 400Â VÂ 3Â AC | 150 m (492 ft) (shielded and unshielded) for frame sizes FSA to FSD | |||||||||
| 200/300Â m (656Â ft/984Â ft) (shielded/unshielded) for frame size FSE | ||||||||||
| Vibration load | ||||||||||
| Transport | 5Â …Â 9Â Hz: Deflection, 3.5Â mm | |||||||||
| 9 … 200 Hz: Vibration 1 × g | ||||||||||
| Vibration class: 2M3 | ||||||||||
| Operation | Area of application IIa | |||||||||
| 10Â …Â 58Â Hz: Deflection, 0.075Â mm (0.003 in) | ||||||||||
| 58 … 200 Hz: Vibration 1 × g | ||||||||||
| Shock load | ||||||||||
| Operation | Area of application II | |||||||||
| Peak acceleration: 5 × g | ||||||||||
| Duration of shock: 30Â ms | ||||||||||
| FSAA | FSAB | FSAC | FSAD | FSA | FSA | FSB | FSC | FSD | FSE | |
| without fan | without fan | with 1Â fan | with 1Â fan | without fan | with 1Â fan | with 1Â fan | with 1Â fan | with 2Â fans | with 2Â fans | |
| Dimensions | ||||||||||
| Width in mm (in) | 68 (2.68) | 68 (2.68) | 90.8 (3.57) | 136.6 (5.38) | 90 (3.54) | 90 (3.54) | 140 (5.51) | 184 (7.24) | 240 (9.45) | 245 (9.65) |
| Height in mm (in) | 142 (5.59) | 142 (5.59) | 160.9 (6.33) | 176.5 (6.95) | 150 (5.91) | 166 (6.54) | 160 (6.3) | 182 (7.17) | 206.5 (8.13) | 264.5 (10.41) |
| Depth in mm (in) | 107.8 (4.24) | 127.8 (5.03) | 147 (5.79) | 158.8 (6.25) | 145.5 (5.73) | 145.5 (5.73) | 164.5 (6.48) | 169 (6.65) | 172.5 (6.79) | 209 (8.23) |
| Weight, approx. | ||||||||||
| 230Â VÂ 1Â AC | ||||||||||
| Without integrated line filter | 0.6 kg (1.32 lb) | 0.8 kg (1.76 lb) | 1.2 kg (2.65 lb) | 1.9 kg (4.19 lb) | – | – | – | – | – | – |
| With integrated line filter Category C1 | 0.7 kg (1.54 lb) | 0.9 kg (1.98 lb) | 1.4 kg (3.09 lb) | 2.2 kg (4.85 lb) | – | – | – | – | – | – |
| 400Â VÂ 3Â AC | ||||||||||
| Without integrated line filter | – | – | – | – | 0.9 kg (1.98 lb) | 1 kg (2.21 lb) | 1.6 kg (3.53 lb) | 2.4 kg (5.29 lb) | 3.9 kg (8.60 lb) | 6.4 kg (14.1 lb) |
| With integrated line filter Category C3 | – | – | – | – | 1 kg (2.21 lb) | 1.1 kg (2.43 lb) | 1.8 kg (3.97 lb) | 2.6 kg (5.73 lb) | 4.3 kg (9.48 lb) | 7 kg (15.4 lb) |
| Mounting clearance, min. | ||||||||||
| Top | 100Â mm (3.94Â in) | |||||||||
| Bottom | 100Â mm (3.94Â in) | |||||||||
| 85Â mm (3.35Â in) for fan-cooled FSA | ||||||||||
| Side | 0Â mm | |||||||||
| Certificates of suitability | cULus, CE, UKCA, RCM, KC | |||||||||
| Environmental classes | Pollution class: 3S2 | |||||||||
| Gas class: 3C2 (SO2, H2S) | ||||||||||
| Climate class: 3K3 | ||||||||||
| CE marking, according to | European Low-Voltage Directive (EN 61800‑5‑1/EN 60204-1), ecodesign requirements of the EU Directive 2019/1781 and European EMC Directive (EN 61800‑3) | |||||||||
| UL marking, according to | UL508C | |||||||||
| EMC standards, radiated emissions and disturbance voltage (conducted emissions) | ||||||||||
| EN 61800‑3 Category C1, 1st environment (residential, commercial) | 230 V 1 AC with integrated line filter or unfiltered with external line filter, shielded cables | |||||||||
| FSAA, FSAB, and FSAD: ≤5 m (16.4 ft) | ||||||||||
| FSAC: ≤10 m (32.8 ft) | ||||||||||
| EN 61800‑3 Category C2, 1st environment (residential, commercial) | 400 V 3 AC without integrated line filter, with external line filter, shielded cables | |||||||||
| FSA 1) to FSE ≤25 m (82 ft) | ||||||||||
| EN 61800‑3 Category C3, 2nd environment (industrial) | 400 V 3 AC with integrated line filter, shielded cables | |||||||||
| FSA: ≤10 m (32.8 ft) | ||||||||||
| FSB to FSD: ≤25 m (82 ft) | ||||||||||
| FSE: ≤50 m (164 ft) | ||||||||||
| Note | The EMC product standard EN 61800‑3 does not apply directly to a frequency converter but to a PDS (Power Drive System), which covers the complete circuitry, motor and cables in addition to the converter. The converters themselves are in general not subject to marking in accordance with the EMC directive. | |||||||||