$ 2,804.62
The CP 443-1 offers communication options with
| Article number | 6GK7443-1EX30-0XE0 | |
| product type designation | CP 443-1 | |
| transfer rate | ||
| transfer rate | ||
| ● at the 1st interface | 10 … 100 Mbit/s | |
| interfaces | ||
| number of interfaces according to Industrial Ethernet | 2 | |
| number of electrical connections | ||
| ● at the 1st interface according to Industrial Ethernet | 2 | |
| type of electrical connection | ||
| ● at the 1st interface according to Industrial Ethernet | RJ45 port | |
| design of the removable storage | ||
| ● C-PLUG | No | |
| supply voltage, current consumption, power loss | ||
| type of voltage of the supply voltage | DC | |
| supply voltage 1 from backplane bus | 5 V | |
| relative symmetrical tolerance at DC | ||
| ● at 5 V | 5 % | |
| consumed current | ||
| ● from backplane bus at DC at 5 V typical | 1.4 A | |
| power loss [W] | 7.25 W | |
| ambient conditions | ||
| ambient temperature | ||
| ● during operation | 0 … 60 °C | |
| ● during storage | -40 … +70 °C | |
| ● during transport | -40 … +70 °C | |
| relative humidity | ||
| ● at 25 °C without condensation during operation maximum | 95 % | |
| protection class IP | IP20 | |
| design, dimensions and weights | ||
| module format | Compact module S7-400 single width | |
| width | 25 mm | |
| height | 290 mm | |
| depth | 210 mm | |
| net weight | 0.7 kg | |
| product features, product functions, product components general | ||
| number of units | ||
| ● per CPU maximum | 14 | |
| ● note | max. 4 as PN IO ctrl. | |
| performance data open communication | ||
| number of possible connections for open communication by means of SEND/RECEIVE blocks maximum | 64 | |
| data volume | ||
| ● as user data per ISO connection for open communication by means of SEND/RECEIVE blocks maximum | 8 Kibyte | |
| ● as user data per ISO on TCP connection for open communication by means of SEND/RECEIVE blocks maximum | 8 Kibyte | |
| ● as user data per TCP connection for open communication by means of SEND/RECEIVE blocks maximum | 8 Kibyte | |
| ● as user data per UDP connection for open IE communication by means of SEND/RECEIVE blocks maximum | 2 Kibyte | |
| number of possible connections for open communication | ||
| ● by means of T blocks maximum | 64 | |
| data volume | ||
| ● as user data per ISO on TCP connection for open communication by means of T blocks maximum | 1 452 byte | |
| performance data S7 communication | ||
| number of possible connections for S7 communication | ||
| ● maximum | 128; when using several CPUs | |
| ● with PG connections maximum | 2 | |
| performance data multi-protocol mode | ||
| number of active connections with multi-protocol mode | 128 | |
| performance data PROFINET communication as PN IO controller | ||
| product function PROFINET IO controller | Yes | |
| number of PN IO devices on PROFINET IO controller operable total | 128 | |
| number of PN IO IRT devices on PROFINET IO controller operable | 64 | |
| number of external PN IO lines with PROFINET per rack | 4 | |
| data volume | ||
| ● as user data for input variables as PROFINET IO controller maximum | 4 Kibyte | |
| ● as user data for output variables as PROFINET IO controller maximum | 4 Kibyte | |
| ● as user data for input variables per PN IO device as PROFINET IO controller maximum | 1 433 byte | |
| ● as user data for output variables per PN IO device as PROFINET IO controller maximum | 1 433 byte | |
| ● as user data for input variables per PN IO device for each sub-module as PROFINET IO controller maximum | 240 byte | |
| ● as user data for output variables per PN IO device for each sub-module as PROFINET IO controller maximum | 240 byte | |
| product functions management, configuration, engineering | ||
| product function MIB support | Yes | |
| protocol is supported | ||
| ● SNMP v1 | Yes | |
| ● DCP | Yes | |
| ● LLDP | Yes | |
| configuration software | ||
| ● required | STEP 7 V5.5 SP3 or higher / STEP 7 Professional V12 (TIA Portal) or higher | |
| product functions diagnostics | ||
| product function web-based diagnostics | Yes | |
| product functions switch | ||
| product feature switch | Yes | |
| product function | ||
| ● switch-managed | No | |
| ● with IRT PROFINET IO switch | Yes | |
| ● configuration with STEP 7 | Yes | |
| product functions redundancy | ||
| product function | ||
| ● ring redundancy | Yes | |
| ● redundancy manager | Yes | |
| protocol is supported Media Redundancy Protocol (MRP) | Yes | |
| product functions security | ||
| product function | ||
| ● password protection for Web applications | No | |
| ● ACL – IP-based | Yes | |
| ● ACL – IP-based for PLC/routing | No | |
| ● switch-off of non-required services | Yes | |
| ● blocking of communication via physical ports | Yes | |
| ● log file for unauthorized access | No | |
| product functions time | ||
| product function SICLOCK support | Yes | |
| product function pass on time synchronization | Yes | |
| protocol is supported | ||
| ● NTP | Yes | |
| ● SIMATIC time synchronization (SIMATIC Time) | Yes | |
| standards, specifications, approvals hazardous environments | ||
| certificate of suitability CCC for hazardous zone according to GB standard | Yes | |