SIMATIC S7-300 – CPU317T-3 PN/DP – Siemens PLC
$ 8,688.14
SKU: 6ES7317-7TK10-0AB0
The CPU 317T-3 PN/DP is used primarily in machines where a control with a large program memory coincides with high processing speed and motion control requirements.
Siemens PLC S7-300 Product Specifications:
Article number | 6ES7317-7TK10-0AB0 | |
CPU317T-3 PN/DP, 1024KB | ||
General information | ||
HW functional status | 1 | |
Firmware version | CPU: V3.2; integrated technology V4.1.5 | |
Product function | ||
● Isochronous mode | Yes; Via PROFIBUS DP or PROFINET interface | |
Engineering with | ||
● Programming package | STEP 7 V5.5 SP2 or higher and S7-Technology option package V4.2 SP3 | |
Supply voltage | ||
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 19.2 V | |
permissible range, upper limit (DC) | 28.8 V | |
external protection for power supply lines (recommendation) | 2 A min. | |
Load voltage L+ | ||
● Rated value (DC) | 24 V | |
● Reverse polarity protection | Yes | |
Digital outputs | ||
— Rated value (DC) | 24 V; 2L+ | |
— Reverse polarity protection | No; 2L+ | |
Input current | ||
Current consumption (rated value) | 1 050 mA | |
Current consumption (in no-load operation), typ. | 230 mA | |
Inrush current, typ. | 6.5 A | |
I²t | 1 A²·s | |
Power loss | ||
Power loss, typ. | 7.5 W | |
Memory | ||
Work memory | ||
● integrated | 1 024 kbyte | |
● expandable | No | |
Load memory | ||
● Plug-in (MMC) | Yes | |
● Plug-in (MMC), max. | 8 Mbyte | |
● Data management on MMC (after last programming), min. | 10 y | |
Backup | ||
● present | Yes; Guaranteed by MMC (maintenance-free) | |
● without battery | Yes; Program and data | |
CPU processing times | ||
for bit operations, typ. | 0.025 µs | |
for word operations, typ. | 0.03 µs | |
for fixed point arithmetic, typ. | 0.04 µs | |
for floating point arithmetic, typ. | 0.16 µs | |
CPU-blocks | ||
Number of blocks (total) | 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | |
DB | ||
● Number, max. | 2 048; Number range: 1 to 16000 | |
● Size, max. | 64 kbyte | |
FB | ||
● Number, max. | 2 048; Number range: 0 to 7999 | |
● Size, max. | 64 kbyte | |
FC | ||
● Number, max. | 2 048; Number range: 0 to 7999 | |
● Size, max. | 64 kbyte | |
OB | ||
● Number, max. | see instruction list | |
● Size, max. | 64 kbyte | |
● Number of free cycle OBs | 1; OB 1 | |
● Number of time alarm OBs | 1; OB 10 | |
● Number of delay alarm OBs | 2; OB 20, 21 | |
● Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 | |
● Number of process alarm OBs | 1; OB 40 | |
● Number of DPV1 alarm OBs | 3; OB 55, 56, 57 | |
● Number of isochronous mode OBs | 1; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously) | |
● Number of technology synchronous alarm OBs | 1; OB 65 | |
● Number of startup OBs | 1; OB 100 | |
● Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) | |
● Number of synchronous error OBs | 2; OB 121, 122 | |
Nesting depth | ||
● per priority class | 16 | |
● additional within an error OB | 4 | |
Counters, timers and their retentivity | ||
S7 counter | ||
● Number | 512 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 511 | |
— preset | Z 0 to Z 7 | |
Counting range | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 999 | |
IEC counter | ||
● present | Yes | |
● Type | SFB | |
● Number | Unlimited (limited only by RAM capacity) | |
S7 times | ||
● Number | 512 | |
Retentivity | ||
— adjustable | Yes | |
— lower limit | 0 | |
— upper limit | 511 | |
— preset | No retentivity | |
Time range | ||
— lower limit | 10 ms | |
— upper limit | 9 990 s | |
IEC timer | ||
● present | Yes | |
● Type | SFB | |
● Number | Unlimited (limited only by RAM capacity) | |
Data areas and their retentivity | ||
Retentive data area (incl. timers, counters, flags), max. | 256 kbyte | |
Flag | ||
● Size, max. | 4 096 byte | |
● Retentivity available | Yes; From MB 0 to MB 4 095 | |
● Retentivity preset | MB 0 to MB 15 | |
● Number of clock memories | 8; 1 memory byte | |
Data blocks | ||
● Retentivity adjustable | Yes; via non-retain property on DB | |
● Retentivity preset | Yes | |
Local data | ||
● per priority class, max. | 32 768 byte; Max. 2048 bytes per block | |
Address area | ||
I/O address area | ||
● Inputs | 8 192 byte | |
● Outputs | 8 192 byte | |
of which distributed | ||
— Inputs | 8 192 byte | |
— Outputs | 8 192 byte | |
Process image | ||
● Inputs | 8 192 byte | |
● Outputs | 8 192 byte | |
● Inputs, adjustable | 8 192 byte | |
● Outputs, adjustable | 8 192 byte | |
● Inputs, default | 256 byte | |
● Outputs, default | 256 byte | |
Default addresses of the integrated channels | ||
— Digital inputs | 66 | |
— Digital outputs | 66 | |
Subprocess images | ||
● Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes | |
Digital channels | ||
● Inputs | 65 536 | |
— of which central | 256 | |
● Outputs | 65 536 | |
— of which central | 256 | |
Analog channels | ||
● Inputs | 4 096 | |
— of which central | 64 | |
● Outputs | 4 096 | |
— of which central | 64 | |
Hardware configuration | ||
Number of expansion units, max. | 0 | |
Number of DP masters | ||
● integrated | 2; 1 DP and 1 DP (drive) | |
● via CP | 2; for DP | |
Number of operable FMs and CPs (recommended) | ||
● FM | 8 | |
● CP, PtP | 8 | |
● CP, LAN | 8 | |
Rack | ||
● Racks, max. | 1 | |
● Modules per rack, max. | 8 | |
Time of day | ||
Clock | ||
● Hardware clock (real-time) | Yes | |
● retentive and synchronizable | Yes | |
● Backup time | 6 wk; At 40 °C ambient temperature | |
● Deviation per day, max. | 10 s; Typ.: 2 s | |
● Behavior of the clock following POWER-ON | Clock continues running after POWER OFF | |
● Behavior of the clock following expiry of backup period | the clock continues at the time of day it had when power was switched off | |
Operating hours counter | ||
● Number | 4 | |
● Number/Number range | 0 to 3 | |
● Range of values | 0 to 2^31 hours (when using SFC 101) | |
● Granularity | 1 h | |
● retentive | Yes; Must be restarted at each restart | |
Clock synchronization | ||
● supported | Yes | |
● to MPI, master | Yes | |
● to MPI, slave | Yes | |
● to DP, master | Yes | |
● to DP, slave | Yes; Only time-of-day slave | |
● in AS, master | Yes | |
● in AS, slave | Yes | |
● on Ethernet via NTP | Yes; As client | |
Digital inputs | ||
Number of digital inputs | 4 | |
● of which inputs usable for technological functions | 4 | |
Input characteristic curve in accordance with IEC 61131, type 1 | Yes | |
Number of simultaneously controllable inputs | ||
horizontal installation | ||
— up to 40 °C, max. | 4 | |
— up to 60 °C, max. | 4 | |
vertical installation | ||
— up to 40 °C, max. | 4 | |
Input voltage | ||
● Rated value (DC) | 24 V | |
● for signal “0” | -3 to +5V | |
● for signal “1” | +15 to +30 V | |
Input current | ||
● for signal “1”, typ. | 7 mA | |
Input delay (for rated value of input voltage) | ||
for technological functions | ||
— at “0” to “1”, max. | 10 µs; Typical | |
— at “1” to “0”, max. | 10 µs; Typical | |
Cable length | ||
● shielded, max. | 1 000 m | |
Digital outputs | ||
Number of digital outputs | 8 | |
● of which high-speed outputs | 8 | |
Functions | for technology functions, e.g. high-speed cam switch signals | |
Short-circuit protection | Yes | |
● Response threshold, typ. | 1 A | |
Limitation of inductive shutdown voltage to | 48 V | |
Controlling a digital input | No | |
Switching capacity of the outputs | ||
● on lamp load, max. | 5 W | |
Load resistance range | ||
● lower limit | 48 Ω | |
● upper limit | 4 kΩ | |
Output voltage | ||
● for signal “0”, max. | 3 V; (2L+) | |
● for signal “1”, min. | Rated voltage -2.5 V | |
Output current | ||
● for signal “1” rated value | 0.5 A | |
● for signal “1” permissible range for 0 to 60 °C, min. | 5 mA | |
● for signal “1” permissible range for 0 to 60 °C, max. | 0.6 A | |
● for signal “0” residual current, max. | 0.3 mA | |
Parallel switching of two outputs | ||
● for uprating | No | |
● for redundant control of a load | No | |
Switching frequency | ||
● with resistive load, max. | 100 Hz | |
● with inductive load, max. | 0.2 Hz; According to IEC 60947-5-1, DC-13 | |
● on lamp load, max. | 100 Hz | |
Total current of the outputs (per group) | ||
horizontal installation | ||
— up to 40 °C, max. | 4 A | |
— up to 60 °C, max. | 3 A | |
all other mounting positions | ||
— up to 40 °C, max. | 4 A | |
Integrated high-speed cams | ||
● Switching accuracy (+/-) | 70 µs | |
Cable length | ||
● shielded, max. | 1 000 m | |
Analog inputs | ||
Number of analog inputs | 0 | |
Analog outputs | ||
Number of analog outputs | 0 | |
Encoder | ||
Connectable encoders | ||
● 2-wire sensor | No | |
Interfaces | ||
Number of industrial Ethernet interfaces | 1 | |
Number of PROFINET interfaces | 1 | |
Number of RS 485 interfaces | 2 | |
Number of RS 422 interfaces | 0 | |
1. Interface | ||
Interface type | Integrated RS 485 interface | |
Isolated | Yes | |
Interface types | ||
● RS 485 | Yes | |
● Output current of the interface, max. | 200 mA | |
Protocols | ||
● MPI | Yes | |
● PROFIBUS DP master | Yes | |
● PROFIBUS DP slave | Yes | |
● Point-to-point connection | No | |
MPI | ||
● Transmission rate, max. | 12 Mbit/s | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— Global data communication | Yes | |
— S7 basic communication | Yes | |
— S7 communication | Yes | |
— S7 communication, as client | No; but via CP and loadable FB | |
— S7 communication, as server | Yes | |
PROFIBUS DP master | ||
● Transmission rate, max. | 12 Mbit/s | |
● Number of DP slaves, max. | 124 | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— Global data communication | No | |
— S7 basic communication | Yes; I blocks only | |
— S7 communication | Yes | |
— S7 communication, as client | No | |
— S7 communication, as server | Yes | |
— Equidistance | Yes | |
— Isochronous mode | Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO | |
— SYNC/FREEZE | Yes | |
— Activation/deactivation of DP slaves | Yes | |
— Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 | |
— Direct data exchange (slave-to-slave communication) | Yes; as subscriber | |
— DPV1 | Yes | |
Address area | ||
— Inputs, max. | 8 kbyte | |
— Outputs, max. | 8 kbyte | |
User data per DP slave | ||
— Inputs, max. | 244 byte | |
— Outputs, max. | 244 byte | |
PROFIBUS DP slave | ||
● Transmission rate, max. | 12 Mbit/s | |
● automatic baud rate search | Yes; only with passive interface | |
● Address area, max. | 32 | |
● User data per address area, max. | 32 byte | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes; Only with active interface | |
— Global data communication | No | |
— S7 basic communication | No | |
— S7 communication | Yes | |
— S7 communication, as client | No | |
— S7 communication, as server | Yes; Connection configured on one side only | |
— Direct data exchange (slave-to-slave communication) | Yes | |
— DPV1 | No | |
Transfer memory | ||
— Inputs | 244 byte | |
— Outputs | 244 byte | |
2. Interface | ||
Interface type | Integrated RS 485 interface | |
Isolated | Yes | |
Interface types | ||
● RS 485 | Yes | |
● Output current of the interface, max. | 200 mA | |
Protocols | ||
● MPI | No | |
● PROFIBUS DP master | Yes; DP(DRIVE)-Master | |
● PROFIBUS DP slave | No | |
● Point-to-point connection | No | |
PROFIBUS DP master | ||
● Transmission rate, max. | 12 Mbit/s | |
● Number of DP slaves, max. | 64 | |
Services | ||
— PG/OP communication | No | |
— Routing | No | |
— Global data communication | No | |
— S7 basic communication | No | |
— S7 communication | No | |
— Equidistance | Yes | |
— Isochronous mode | Yes | |
— SYNC/FREEZE | No | |
— Activation/deactivation of DP slaves | Yes | |
— DPV1 | No | |
Address area | ||
— Inputs, max. | 1 024 byte | |
— Outputs, max. | 1 024 byte | |
User data per DP slave | ||
— Inputs, max. | 244 byte | |
— Outputs, max. | 244 byte | |
PROFIBUS DP slave | ||
● GSD file | http://support.automation.siemens.com in Product Support area | |
● Transmission rate, max. | 12 Mbit/s | |
3. Interface | ||
Interface type | PROFINET | |
Isolated | Yes | |
automatic detection of transmission rate | Yes; 10/100 Mbit/s | |
Autonegotiation | Yes | |
Autocrossing | Yes | |
Change of IP address at runtime, supported | Yes | |
Interface types | ||
● RJ 45 (Ethernet) | Yes | |
● Number of ports | 2 | |
● integrated switch | Yes | |
Protocols | ||
● MPI | No | |
● PROFINET IO Controller | Yes; Also simultaneously with IO-Device functionality | |
● PROFINET IO Device | Yes; Also simultaneously with IO Controller functionality | |
● PROFIBUS DP master | No | |
● PROFIBUS DP slave | No | |
● Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP | |
● Web server | Yes | |
● Media redundancy | Yes | |
PROFINET IO Controller | ||
● Transmission rate, max. | 100 Mbit/s | |
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 | |
— Isochronous mode | Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO | |
— Shared device | Yes | |
— Prioritized startup | Yes | |
— Number of IO devices with prioritized startup, max. | 32 | |
— Number of connectable IO Devices, max. | 128 | |
— Of which IO devices with IRT, max. | 64 | |
— of which in line, max. | 64 | |
— Number of connectable IO Devices for RT, max. | 128 | |
— of which in line, max. | 128 | |
— Activation/deactivation of IO Devices | Yes | |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 | |
— IO Devices changing during operation (partner ports), supported | Yes | |
— Number of IO Devices per tool, max. | 8 | |
— Device replacement without swap medium | Yes | |
— Send cycles | 250 µs, 500 µs, 1 ms, 2 ms, 4 ms | |
— Updating time | 250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, technical Data” for more details) | |
Address area | ||
— Inputs, max. | 8 kbyte | |
— Outputs, max. | 8 kbyte | |
— User data consistency, max. | 1 024 byte | |
PROFINET IO Device | ||
Services | ||
— PG/OP communication | Yes | |
— Routing | Yes | |
— S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 | |
— Isochronous mode | No | |
— IRT | Yes | |
— PROFIenergy | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device | |
— Shared device | Yes | |
— Number of IO Controllers with shared device, max. | 2 | |
Transfer memory | ||
— Inputs, max. | 1 440 byte; Per IO Controller with shared device | |
— Outputs, max. | 1 440 byte; Per IO Controller with shared device | |
Submodules | ||
— Number, max. | 64 | |
— User data per submodule, max. | 1 024 byte | |
Open IE communication | ||
● Number of connections, max. | 16 | |
● Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 | |
● Keep-alive function, supported | Yes | |
Protocols | ||
PROFIsafe | No | |
Redundancy mode | ||
Media redundancy | ||
— Switchover time on line break, typ. | 200 ms; PROFINET MRP | |
— Number of stations in the ring, max. | 50 | |
Open IE communication | ||
● TCP/IP | Yes; via integrated PROFINET interface and loadable FBs | |
— Number of connections, max. | 16 | |
— Data length for connection type 01H, max. | 1 460 byte | |
— Data length for connection type 11H, max. | 32 768 byte | |
— several passive connections per port, supported | Yes | |
● ISO-on-TCP (RFC1006) | Yes; via integrated PROFINET interface and loadable FBs | |
— Number of connections, max. | 16 | |
— Data length, max. | 32 768 byte | |
● UDP | Yes; via integrated PROFINET interface and loadable FBs | |
— Number of connections, max. | 16 | |
— Data length, max. | 1 472 byte | |
Web server | ||
● supported | Yes | |
● User-defined websites | Yes | |
● Number of HTTP clients | 5 | |
communication functions / header | ||
PG/OP communication | Yes | |
Data record routing | Yes | |
Global data communication | ||
● supported | Yes | |
● Number of GD loops, max. | 8 | |
● Number of GD packets, max. | 8 | |
● Number of GD packets, transmitter, max. | 8 | |
● Number of GD packets, receiver, max. | 8 | |
● Size of GD packets, max. | 22 byte | |
● Size of GD packet (of which consistent), max. | 22 byte | |
S7 basic communication | ||
● supported | Yes | |
● User data per job, max. | 76 byte | |
● User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) | |
S7 communication | ||
● supported | Yes | |
● as server | Yes | |
● as client | Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB | |
● User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) | |
S5 compatible communication | ||
● supported | Yes; via CP and loadable FC | |
Number of connections | ||
● overall | 32 | |
● usable for PG communication | 31 | |
— reserved for PG communication | 1 | |
— adjustable for PG communication, min. | 1 | |
— adjustable for PG communication, max. | 31 | |
● usable for OP communication | 31 | |
— reserved for OP communication | 1 | |
— adjustable for OP communication, min. | 1 | |
— adjustable for OP communication, max. | 31 | |
● usable for S7 basic communication | 30 | |
— reserved for S7 basic communication | 0 | |
— adjustable for S7 basic communication, min. | 0 | |
— adjustable for S7 basic communication, max. | 30 | |
● usable for S7 communication | 16 | |
— reserved for S7 communication | 0 | |
— adjustable for S7 communication, min. | 0 | |
— adjustable for S7 communication, max. | 16 | |
● total number of instances, max. | 32 | |
● usable for routing | X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. | |
S7 message functions | ||
Number of login stations for message functions, max. | 32; Depending on the configured connections for PG/OP and S7 basic communication | |
Process diagnostic messages | Yes | |
simultaneously active Alarm-S blocks, max. | 300 | |
Test commissioning functions | ||
Status block | Yes; Up to 2 simultaneously | |
Single step | Yes | |
Number of breakpoints | 4; without continuation | |
Status/control | ||
● Status/control variable | Yes | |
● Variables | Inputs, outputs, memory bits, DB, times, counters | |
● Number of variables, max. | 30 | |
— of which status variables, max. | 30 | |
— of which control variables, max. | 14 | |
Forcing | ||
● Forcing | Yes | |
● Forcing, variables | Inputs, outputs | |
● Number of variables, max. | 10 | |
Diagnostic buffer | ||
● present | Yes | |
● Number of entries, max. | 500 | |
— adjustable | No | |
— of which powerfail-proof | 100; Only the last 100 entries are retained | |
● Number of entries readable in RUN, max. | 499 | |
— adjustable | Yes; From 10 to 499 | |
— preset | 10 | |
Service data | ||
● can be read out | Yes | |
Interrupts/diagnostics/status information | ||
Alarms | No | |
Diagnostics function | No | |
Diagnostics indication LED | ||
● Status indicator digital input (green) | Yes | |
● Status indicator digital output (green) | Yes | |
Potential separation | ||
Potential separation digital inputs | ||
● between the channels and backplane bus | Yes | |
Potential separation digital outputs | ||
● between the channels and backplane bus | Yes | |
Isolation | ||
Isolation tested with | 500 V DC | |
Ambient conditions | ||
Ambient temperature during operation | ||
● min. | 0 °C | |
● max. | 60 °C | |
configuration / header | ||
Configuration software | ||
● STEP 7 | Yes; STEP 7 V5.5 SP2 or higher and S7-Technology option package V4.2 SP3 | |
configuration / programming / header | ||
● Command set | see instruction list | |
● Nesting levels | 8 | |
● System functions (SFC) | see instruction list | |
● System function blocks (SFB) | see instruction list | |
Programming language | ||
— LAD | Yes | |
— FBD | Yes | |
— STL | Yes | |
— SCL | Yes | |
— CFC | Yes | |
— GRAPH | Yes | |
— HiGraph® | Yes | |
Know-how protection | ||
● User program protection/password protection | Yes | |
● Block encryption | Yes; With S7 block Privacy | |
Dimensions | ||
Width | 120 mm | |
Height | 125 mm | |
Depth | 130 mm | |
Weights | ||
Weight, approx. | 640 g |
Weight | 0.713 kg |
---|---|
Dimensions | 13.1 × 15.1 × 13.1 cm |