$ 4,351.55
The CPU 319-3 PN/DP is the fastest S7-300 CPU with a large program memory. It is used in plants containing distributed automation structures in addition to centralized I/O. It is used, for example, as central controller in production lines or as machine controller with high processing speed demands.
Its quantity framework makes it optimally suitable for use of SIMATIC engineering tools.
Article number | 6ES7318-3EL01-0AB0 |
CPU319-3 PN/DP, 2 MB | |
General information | |
HW functional status | 1 |
Firmware version | V3.2 |
Product function | |
● Isochronous mode | Yes; Via 2nd PROFIBUS DP or PROFINET interface |
Engineering with | |
● Programming package | STEP 7 V5.5 or higher |
Supply voltage | |
Rated value (DC) | 24 V |
permissible range, lower limit (DC) | 19.2 V |
permissible range, upper limit (DC) | 28.8 V |
external protection for power supply lines (recommendation) | 2 A min. |
Mains buffering | |
● Mains/voltage failure stored energy time | 5 ms |
● Repeat rate, min. | 1 s |
Input current | |
Current consumption (rated value) | 1 250 mA |
Current consumption (in no-load operation), typ. | 500 mA |
Inrush current, typ. | 4 A |
I²t | 1.2 A²·s |
Power loss | |
Power loss, typ. | 14 W |
Memory | |
Work memory | |
● integrated | 2 048 kbyte |
● expandable | No |
Load memory | |
● Plug-in (MMC) | Yes |
● Plug-in (MMC), max. | 8 Mbyte |
● Data management on MMC (after last programming), min. | 10 y |
Backup | |
● present | Yes |
● without battery | Yes |
CPU processing times | |
for bit operations, typ. | 0.004 µs |
for word operations, typ. | 0.01 µs |
for fixed point arithmetic, typ. | 0.01 µs |
for floating point arithmetic, typ. | 0.04 µs |
CPU-blocks | |
Number of blocks (total) | 4 096; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB | |
● Number, max. | 4 096; Number range: 1 to 16000 |
● Size, max. | 64 kbyte |
FB | |
● Number, max. | 4 096; Number range: 0 to 7999 |
● Size, max. | 64 kbyte |
FC | |
● Number, max. | 4 096; Number range: 0 to 7999 |
● Size, max. | 64 kbyte |
OB | |
● Size, max. | 64 kbyte |
● Number of free cycle OBs | 1; OB 1 |
● Number of time alarm OBs | 1; OB 10 |
● Number of delay alarm OBs | 2; OB 20, 21 |
● Number of cyclic interrupt OBs | 4; OB 32, 33, 34, 35 (OB 35: smallest settable clock pulse = 500 µs) |
● Number of process alarm OBs | 1; OB 40 |
● Number of DPV1 alarm OBs | 3; OB 55, 56, 57 |
● Number of isochronous mode OBs | 1; OB 61 |
● Number of startup OBs | 1; OB 100 |
● Number of asynchronous error OBs | 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) |
● Number of synchronous error OBs | 2; OB 121, 122 |
Nesting depth | |
● per priority class | 16 |
● additional within an error OB | 4 |
Counters, timers and their retentivity | |
S7 counter | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | Z 0 to Z 7 |
Counting range | |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 999 |
IEC counter | |
● present | Yes |
● Type | SFB |
● Number | Unlimited (limited only by RAM capacity) |
S7 times | |
● Number | 2 048 |
Retentivity | |
— adjustable | Yes |
— lower limit | 0 |
— upper limit | 2 047 |
— preset | No retentivity |
Time range | |
— lower limit | 10 ms |
— upper limit | 9 990 s |
IEC timer | |
● present | Yes |
● Type | SFB |
● Number | Unlimited (limited only by RAM capacity) |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 700 kbyte |
Flag | |
● Size, max. | 8 192 byte |
● Retentivity available | Yes; From MB 0 to MB 8 191 |
● Retentivity preset | MB 0 to MB 15 |
● Number of clock memories | 8; 1 memory byte |
Data blocks | |
● Retentivity adjustable | Yes; via non-retain property on DB |
● Retentivity preset | Yes |
Local data | |
● per priority class, max. | 32 768 byte; Max. 2048 bytes per block |
Address area | |
I/O address area | |
● Inputs | 8 192 byte |
● Outputs | 8 192 byte |
of which distributed | |
— Inputs | 8 192 byte |
— Outputs | 8 192 byte |
Process image | |
● Inputs | 8 192 byte |
● Outputs | 8 192 byte |
● Inputs, adjustable | 8 192 byte |
● Outputs, adjustable | 8 192 byte |
● Inputs, default | 256 byte |
● Outputs, default | 256 byte |
Subprocess images | |
● Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes |
Digital channels | |
● Inputs | 65 536 |
— of which central | 1 024 |
● Outputs | 65 536 |
— of which central | 1 024 |
Analog channels | |
● Inputs | 4 096 |
— of which central | 256 |
● Outputs | 4 096 |
— of which central | 256 |
Hardware configuration | |
Number of DP masters | |
● integrated | 2 |
● via CP | 4 |
Number of operable FMs and CPs (recommended) | |
● FM | 8 |
● CP, PtP | 8 |
● CP, LAN | 10 |
Rack | |
● Racks, max. | 4 |
● Modules per rack, max. | 8 |
Time of day | |
Clock | |
● Hardware clock (real-time) | Yes |
● retentive and synchronizable | Yes |
● Backup time | 6 wk; At 40 °C ambient temperature |
● Deviation per day, max. | 10 s; Typ.: 2 s |
● Behavior of the clock following POWER-ON | Clock continues running after POWER OFF |
● Behavior of the clock following expiry of backup period | the clock continues at the time of day it had when power was switched off |
Operating hours counter | |
● Number | 4 |
● Number/Number range | 0 to 3 |
● Range of values | 0 to 2^31 hours (when using SFC 101) |
● Granularity | 1 h |
● retentive | Yes; Must be restarted at each restart |
Clock synchronization | |
● supported | Yes |
● to MPI, master | Yes |
● to MPI, slave | Yes |
● to DP, master | Yes; With DP slave only slave clock |
● to DP, slave | Yes |
● in AS, master | Yes |
● in AS, slave | Yes |
● on Ethernet via NTP | Yes; As client |
Digital inputs | |
Number of digital inputs | 0 |
Digital outputs | |
Number of digital outputs | 0 |
Analog inputs | |
Number of analog inputs | 0 |
Analog outputs | |
Number of analog outputs | 0 |
Interfaces | |
Number of industrial Ethernet interfaces | 1; 2 ports (switch) RJ45 |
Number of PROFINET interfaces | 1; 2 ports (switch) RJ45 |
Number of RS 485 interfaces | 2; Combined MPI / PROFIBUS DP and PROFIBUS DP |
Number of RS 422 interfaces | 0 |
1. Interface | |
Interface type | Integrated RS 485 interface |
Isolated | Yes |
Interface types | |
● RS 485 | Yes |
● Output current of the interface, max. | 150 mA |
Protocols | |
● MPI | Yes |
● PROFIBUS DP master | Yes |
● PROFIBUS DP slave | Yes; A DP slave at both interfaces simultaneously is not possible |
● Point-to-point connection | No |
MPI | |
● Transmission rate, max. | 12 Mbit/s |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | Yes |
— S7 basic communication | Yes |
— S7 communication | Yes |
— S7 communication, as client | No; but via CP and loadable FB |
— S7 communication, as server | Yes |
PROFIBUS DP master | |
● Transmission rate, max. | 12 Mbit/s |
● Number of DP slaves, max. | 124 |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | Yes; I blocks only |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes |
— Equidistance | Yes |
— Isochronous mode | No |
— SYNC/FREEZE | Yes |
— Activation/deactivation of DP slaves | Yes |
— Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 |
— Direct data exchange (slave-to-slave communication) | Yes; as subscriber |
— DPV1 | Yes |
Address area | |
— Inputs, max. | 8 kbyte |
— Outputs, max. | 8 kbyte |
User data per DP slave | |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
PROFIBUS DP slave | |
● Transmission rate, max. | 12 Mbit/s |
● automatic baud rate search | Yes; only with passive interface |
● Address area, max. | 32 |
● User data per address area, max. | 32 byte |
Services | |
— PG/OP communication | Yes |
— Routing | Yes; with interface active |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes; Connection configured on one side only |
— Direct data exchange (slave-to-slave communication) | Yes |
— DPV1 | No |
Transfer memory | |
— Inputs | 244 byte |
— Outputs | 244 byte |
2. Interface | |
Interface type | Integrated RS 485 interface |
Isolated | Yes |
Interface types | |
● RS 485 | Yes |
● Output current of the interface, max. | 200 mA |
Protocols | |
● MPI | No |
● PROFINET IO Controller | No |
● PROFINET IO Device | No |
● PROFINET CBA | No |
● PROFIBUS DP master | Yes |
● PROFIBUS DP slave | Yes; A DP slave at both interfaces simultaneously is not possible |
● Open IE communication | No |
● Web server | No |
PROFIBUS DP master | |
● Transmission rate, max. | 12 Mbit/s |
● Number of DP slaves, max. | 124 |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— Global data communication | No |
— S7 basic communication | Yes; I blocks only |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes; Connection configured on one side only |
— Equidistance | Yes |
— Isochronous mode | Yes; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously) |
— SYNC/FREEZE | Yes |
— Activation/deactivation of DP slaves | Yes |
— Number of DP slaves that can be simultaneously activated/deactivated, max. | 8 |
— Direct data exchange (slave-to-slave communication) | Yes; as subscriber |
— DPV1 | Yes |
Address area | |
— Inputs, max. | 8 kbyte |
— Outputs, max. | 8 kbyte |
User data per DP slave | |
— Inputs, max. | 244 byte |
— Outputs, max. | 244 byte |
PROFIBUS DP slave | |
● GSD file | The latest GSD file is available at: http://www.siemens.com/profibus-gsd |
● Transmission rate, max. | 12 Mbit/s |
● automatic baud rate search | Yes; only with passive interface |
● Address area, max. | 32 |
● User data per address area, max. | 32 byte |
Services | |
— PG/OP communication | Yes |
— Routing | Yes; with interface active |
— Global data communication | No |
— S7 basic communication | No |
— S7 communication | Yes |
— S7 communication, as client | No |
— S7 communication, as server | Yes; Connection configured on one side only |
— Direct data exchange (slave-to-slave communication) | Yes |
— DPV1 | No |
Transfer memory | |
— Inputs | 244 byte |
— Outputs | 244 byte |
3. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes; 10/100 Mbit/s |
Autonegotiation | Yes |
Autocrossing | Yes |
Change of IP address at runtime, supported | Yes |
Interface types | |
● RJ 45 (Ethernet) | Yes |
● Number of ports | 2 |
● integrated switch | Yes |
Protocols | |
● MPI | No |
● PROFINET IO Controller | Yes; Also simultaneously with I-Device functionality |
● PROFINET IO Device | Yes; Also simultaneously with IO Controller functionality |
● PROFINET CBA | Yes |
● PROFIBUS DP master | No |
● PROFIBUS DP slave | No |
● Open IE communication | Yes; Via TCP/IP, ISO on TCP, and UDP |
● Web server | Yes |
● Media redundancy | Yes |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
— Isochronous mode | Yes; OB 61 – isochronous mode is possible either on DP or PROFINET IO (not simultaneously) |
— Shared device | Yes |
— Prioritized startup | Yes |
— Number of IO devices with prioritized startup, max. | 32 |
— Number of connectable IO Devices, max. | 256 |
— Of which IO devices with IRT, max. | 64 |
— of which in line, max. | 64 |
— Number of IO Devices with IRT and the option “high flexibility” | 256 |
— of which in line, max. | 61 |
— Number of connectable IO Devices for RT, max. | 256 |
— of which in line, max. | 256 |
— Activation/deactivation of IO Devices | Yes |
— Number of IO Devices that can be simultaneously activated/deactivated, max. | 8 |
— IO Devices changing during operation (partner ports), supported | Yes |
— Number of IO Devices per tool, max. | 8 |
— Device replacement without swap medium | Yes |
— Send cycles | 250 μs, 500 μs,1 ms; 2 ms, 4 ms (not in the case of IRT with “high flexibility” option) |
— Updating time | 250 µs to 512 ms (depending on the operating mode, see Manual “S7-300 CPU 31xC and CPU 31x, technical Data” for more details) |
Address area | |
— Inputs, max. | 8 kbyte |
— Outputs, max. | 8 kbyte |
— User data consistency, max. | 1 024 byte |
PROFINET IO Device | |
Services | |
— PG/OP communication | Yes |
— Routing | Yes |
— S7 communication | Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 |
— Isochronous mode | No |
— IRT | Yes |
— PROFIenergy | Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device |
— Shared device | Yes |
— Number of IO Controllers with shared device, max. | 2 |
Transfer memory | |
— Inputs, max. | 1 440 byte; Per IO Controller with shared device |
— Outputs, max. | 1 440 byte; Per IO Controller with shared device |
Submodules | |
— Number, max. | 64 |
— User data per submodule, max. | 1 024 byte |
PROFINET CBA | |
● acyclic transmission | Yes |
● cyclic transmission | Yes |
Open IE communication | |
● Number of connections, max. | 32 |
● Local port numbers used at the system end | 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 |
● Keep-alive function, supported | Yes |
Protocols | |
PROFIsafe | No |
Redundancy mode | |
Media redundancy | |
— Switchover time on line break, typ. | 200 ms; PROFINET MRP |
— Number of stations in the ring, max. | 50 |
Open IE communication | |
● TCP/IP | Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. | 32 |
— Data length for connection type 01H, max. | 1 460 byte |
— Data length for connection type 11H, max. | 32 768 byte |
— several passive connections per port, supported | Yes |
● ISO-on-TCP (RFC1006) | Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. | 32 |
— Data length, max. | 32 768 byte |
● UDP | Yes; via integrated PROFINET interface and loadable FBs |
— Number of connections, max. | 32 |
— Data length, max. | 1 472 byte |
Web server | |
● supported | Yes |
● User-defined websites | Yes |
● Number of HTTP clients | 5 |
communication functions / header | |
PG/OP communication | Yes |
Data record routing | Yes |
Global data communication | |
● supported | Yes |
● Number of GD loops, max. | 8 |
● Number of GD packets, max. | 8 |
● Number of GD packets, transmitter, max. | 8 |
● Number of GD packets, receiver, max. | 8 |
● Size of GD packets, max. | 22 byte |
● Size of GD packet (of which consistent), max. | 22 byte |
S7 basic communication | |
● supported | Yes |
● User data per job, max. | 76 byte |
● User data per job (of which consistent), max. | 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication | |
● supported | Yes |
● as server | Yes |
● as client | Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB |
● User data per job, max. | See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
S5 compatible communication | |
● supported | Yes; via CP and loadable FC |
communication functions / PROFINET CBA (with set target communication load) / header | |
● Setpoint for the CPU communication load | 20 % |
● number of remote connection partners / with PROFINET CBA | 32 |
● number of technological functions / with PROFINET CBA / for master or slave | 50 |
● number of connections / with PROFINET CBA / for master or slave / total | 3 000 |
● data volume / of the input variables / with PROFINET CBA / for master or slave | 24 000 byte |
● data volume / of the output variables / with PROFINET CBA / for master or slave | 24 000 byte |
● number of internal and PROFIBUS interconnections / with PROFINET CBA / maximum | 1 000 |
● data volume / of internal and PROFIBUS interconnections / with PROFINET CBA / for master or slave | 8 000 byte |
● data volume / with PROFINET CBA / per connection / maximum | 1 400 byte |
performance data / PROFINET CBA / remote interconnection / with acyclic transfer / header | |
— update time / of the remote interconnections / in the case of acyclic transmission / with PROFINET CBA | 200 ms |
— number of remote connections to input variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 100 |
— number of remote connections to output variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 100 |
— data volume / as user data for remote interconnections with input variables / in the case of acyclic transmission / with PROFINET CBA | 3 200 byte |
— data volume / as user data for remote interconnections with output variables / in the case of acyclic transmission / with PROFINET CBA | 3 200 byte |
— data volume / as user data for remote interconnections / in the case of acyclic transmission / with PROFINET CBA / per connection / maximum | 1 400 byte |
performance data / PROFINET CBA / remote interconnection / with cyclic transfer / header | |
— update time / of the remote interconnections / with cyclical transfer / with PROFINET CBA | 1 ms |
— number of remote connections to input variables / with PROFINET CBA / with cyclic transfer / maximum | 300 |
— number of remote connections to output variables / with cyclical transfer / with PROFINET CBA / maximum | 300 |
— data volume / as user data for remote interconnections with input variables / with cyclical transfer / with PROFINET CBA / maximum | 4 800 byte |
— data volume / as user data for remote interconnections with output variables / with cyclical transfer / with PROFINET CBA / maximum | 4 800 byte |
— data volume / as user data for remote interconnections / with cyclical transfer / with PROFINET CBA / per connection / maximum | 450 byte |
performance data / PROFINET CBA / HMI variables via PROFINET / acyclic / header | |
— number of connectable HMI stations / for HMI variables / in the case of acyclic transmission / with PROFINET CBA | 3; 2x PN OPC/1x iMap |
— update time / of the HMI variables / in the case of acyclic transmission / with PROFINET CBA | 500 ms |
— number of HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 600 |
— data volume / as user data for HMI variables / in the case of acyclic transmission / with PROFINET CBA / maximum | 9 600 byte |
performance data / PROFINET CBA / PROFIBUS proxy functionality / header | |
— product function / with PROFINET CBA / PROFIBUS proxy functionality | Yes |
— number of coupled PROFIBUS devices / with PROFIBUS functionality | 32 |
— data volume / with PROFIBUS proxy functionality / with PROFINET CBA / per connection / maximum | 240 byte; Slave-dependent |
Number of connections | |
● overall | 32 |
● usable for PG communication | 31 |
— reserved for PG communication | 1 |
— adjustable for PG communication, min. | 1 |
— adjustable for PG communication, max. | 31 |
● usable for OP communication | 31 |
— reserved for OP communication | 1 |
— adjustable for OP communication, min. | 1 |
— adjustable for OP communication, max. | 31 |
● usable for S7 basic communication | 30 |
— reserved for S7 basic communication | 0 |
— adjustable for S7 basic communication, min. | 0 |
— adjustable for S7 basic communication, max. | 30 |
● usable for S7 communication | 16 |
— reserved for S7 communication | 0 |
— adjustable for S7 communication, min. | 0 |
— adjustable for S7 communication, max. | 16 |
● total number of instances, max. | 32 |
● usable for routing | X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as DP master: max. 24; X2 as DP slave (active): max. 14; X3 as PROFINET: 48 max. |
S7 message functions | |
Number of login stations for message functions, max. | 32; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages | Yes |
simultaneously active Alarm-S blocks, max. | 300 |
Test commissioning functions | |
Status block | Yes; Up to 2 simultaneously |
Single step | Yes |
Number of breakpoints | 4 |
Status/control | |
● Status/control variable | Yes |
● Variables | Inputs, outputs, memory bits, DB, times, counters |
● Number of variables, max. | 30 |
— of which status variables, max. | 30 |
— of which control variables, max. | 14 |
Forcing | |
● Forcing | Yes |
● Forcing, variables | Inputs, outputs |
● Number of variables, max. | 10 |
Diagnostic buffer | |
● present | Yes |
● Number of entries, max. | 500 |
— adjustable | No |
— of which powerfail-proof | 100 |
● Number of entries readable in RUN, max. | 499 |
— adjustable | Yes; From 10 to 499 |
— preset | 10 |
Service data | |
● can be read out | Yes |
Ambient conditions | |
Ambient temperature during operation | |
● min. | 0 °C |
● max. | 60 °C |
configuration / header | |
Configuration software | |
● STEP 7 | Yes; V5.5 or higher |
configuration / programming / header | |
● Command set | see instruction list |
● Nesting levels | 8 |
● System functions (SFC) | see instruction list |
● System function blocks (SFB) | see instruction list |
Programming language | |
— LAD | Yes |
— FBD | Yes |
— STL | Yes |
— SCL | Yes |
— CFC | Yes |
— GRAPH | Yes |
— HiGraph® | Yes |
Know-how protection | |
● User program protection/password protection | Yes |
● Block encryption | Yes; With S7 block Privacy |
Dimensions | |
Width | 120 mm |
Height | 125 mm |
Depth | 130 mm |
Weights | |
Weight, approx. | 1 250 g |
Weight | 1.392 kg |
---|---|
Dimensions | 16.4 × 18.2 × 15.9 cm |
INOSAKI Limited
RM B 5/F Gaylord Comm,
Bldg 114-118 Lockhart Rd.
Hong Kong
INOSAKI Sdn. Bhd.
2-1-9, Ground Floor, One Square, Tingkat Mahsuri 1,
11900 Bayan Lepas, Penan
INOSAKI Pte. Ltd.
101 Upper Cross Street,
No. 06-17, People’s Park Centre,
Singapore (058357)